Restore Default Factory Settings
Before using the system for the first time,
restore default factory settings. Your control
panel may have been tested by the dealer or
installer, and some settings may have been
changed.
1. Press Tool button to access the Settings
Menu (bottom right in Main Menu).
2. Press down arrow, until Reset button is
displayed.
3. Press the Reset button to proceed.
Setup Expansion Tank Pump
To use the 12v circulation pump in the
expansion tank, you must set it up. This is not
a default factory setting.
NB: Under factory settings, the system will use
the 12v inline circulation pump by default.
1. Press Tool button to access the Settings
Menu (bottom right in Main Menu).
2. Press down arrow, until Circulation Pump
button is displayed.
3. Press Circulation Pump button, select
Expansion Tank Pump to proceed.
Set up Antimicrobial Function
To actively kill Legionella, set up the
Antimicrobial function. At 2:00 every night,
the hot water will be heated to over 65°C
for 30 mins. This further reduces the risk of
Legionella.
1. Press Tool button to access the Settings
Menu (bottom right in Main Menu).
2. Press down arrow, until Antimicrobial button
is displayed.
3. Press Antimicrobial button to proceed.
Setup Standby Screen for Bedtime
The backlight on the Standby Screen can be
disturbing if the control panel is visible from
your bed. It can be inverted for white text on
black background.
1. Press Tool button to access the Settings
Menu (bottom right in Main Menu).
2. Press down arrow, until Backlight button is
displayed.
3. Press Backlight button, select Inverted to
proceed.
Maintenance
The
Alde
control
panel
requires
no
maintenance, other than cleaning of the screen
as needed. Use a microfibre cloth to clean the
touchscreen.
NB: Consider removing the Alde control panel
over winter, if the vehicle is to be kept in
storage and is susceptible to damp.
Troubleshooting
Any error messages will be displayed on
the Standby Screen. Error messages can be
cleared by switching off 12v supply to the
boiler for 10 secs.
The system is completely dead, the control
panel is blank
• Check the 20mm T3.15Amp glass fuse in
the boiler. This is located under the lid of
the black plastic service hatch, in a green
plastic fuse holder.
• Check the 12v supply to the boiler, it should
be above 12v.
• Check the 12v cable is plugged into the
boiler. Check the cable is plugged into the
Alde control panel.
“Panel failure 1” & and “Panel failure 2”
• Moisture is trapped in the control panel.
• Remove the Alde control panel from
the vehicle and air in a warm, dry place
overnight.
“Gas failure”
• Out of gas or gas is not igniting.
• Check the gas cylinder is full. Try a different
gas cylinder, ensuring it is propane gas.
61
6
FITTED E
QUIPMENT
- T
he Alde He
ating S
y
st
em
FITTED EQUIPMENT- The Alde Heating System
Summary of Contents for Approach
Page 1: ...Owner s Manual ...
Page 2: ......
Page 36: ...33 5 CONNECTION OF SERVICES The Water System CONNECTION OF SERVICES The Water System ...
Page 45: ......
Page 98: ......
Page 107: ...1 0 4 NOTES ...
Page 108: ...1 0 5 10 Notes NOTES ...
Page 109: ...1 0 6 NOTES ...
Page 110: ...1 0 7 10 Notes NOTES ...