Improper connection of the equipment-grounding conductor can result in risk of electric
shock. The conductor with insulation having an outer surface that is green with or without
yellow stripes is the equipment-grounding conductor. If repair or replacement of the electric
cord or plug is necessary, do not connect the equipment-grounding conductor to a live
terminal.
•
Check with a qualified electrician or service personnel if the grounding instructions are not
completely understood, or if in doubt as to whether the machine is properly grounded.
•
Repair or replace damaged or worn cord immediately.
Electrical Enclosure
Disconnect and lockout power to the saw!
Use the specific triangle socket key tools enclosed to unlock the electrical enclosure door.
Notes for wiring:
Power input: AC5V and AC12V / 50~60HZ.
Signal input: Standard proximity sensor or encoder A, B phase signal (DC12V).
Unit of measurement: Degrees.
Don't connect the shielded cable of the induction unit to circuit 0V or GND.
Sensor shielded cables please direct connection to the controller.
For reducing controller interference. Use separate signal wire and power wire.
The programmable controller is intended of use in Zone B typical industrial environment.
Important:
•
The fuse in the signal circuit cannot exceed 3A. Customer supplied.
•
Electrical technician and operator must obey above-mentioned items. Changing internal
wiring or circuit protection may cause controller burnt out other mechanical damage, this will
void the warranty.
WARNING:
In all cases, make certain the receptacle in question is
properly grounded. If you are not sure, have a qualified electrician check the
receptacle
.