5
BF-UM-C-DP E171-EN November 2019
USER MANU
AL FOR DISPL
A
Y
7.7 ERROR CODE DEFINITION
The display can show the errors of a pedelec. When the fault is detected, the RGB lights will flash at a frequency
of 1 Hz. The flashing blue light indicates the tens digit of the error code, while the flashing cyan light indicates
the unit digit. For example:
Error code 25 :
The blue light flickers for 2 times, and the cyan light flickers for 5 times.
Note:
Please read carefully the description of the error code. When the error code appears, please first restart the
system. If the problem is not eliminated, please contact your dealer or technical personnel.
Error
Declaration
Troubleshooting
04
The throttle has fault.
1. Check whether the connector of the throttle are
correctly connected.
2. Disconnect the throttle, if the problem still occurs,
please contact your retailer.
05
The throttle is not back in its
correct position.
Check the throttle can adjust back into its correct
position, if the situation does not improve, please
change to a new throttle.
07
Overvoltage protection
1. Remove the battery.
2. Re-Insert the battery.
3. If the problem persists, please contact your retailer.
08
Error with the hall sensor signal
inside the motor
Please contact your retailer.
09
Error with the Engine phases
Please contact your retailer.
10
The temperature inside the en-
gine has reached its maximum
protection value
1. Turn off the system and allow the Pedelec to cool
down.
2. If the problem persists, please contact your retailer.
11
The temperature sensor inside
the motor has an error
Please contact your retailer.
12
Error with the current sensor in
the controller
Please contact your retailer.
13
Error with the temperature
sensor inside of the battery
Please contact your retailer.