13
DISPLAY MANUAL
DP C240.CAN
FUNCTIONS SETTING
Limit”. Press and hold “+” and “-” synchro-
nously to exit back to the main interface, or
you can also select “BACK”
→
“EXIT”to exit
back to the main interface.
•
Check record of error code
After entering into “Information” menu,
then briefly press “+” or “-” to go to ” Error
Code”, and then briefly press ”ON/OFF” to
review the last ten error codes record from
“E-Code0” to “E-Code9”, then briefly press
”ON/OFF” to exit back to the “Information”.
Press and hold “+” and “-” synchronously to
save and exit back to the main interface.
•
Battery data review
After entering into “Information” menu,
then briefly press “+” or “-” to go to “Battery
Info.”, and then briefly press ”ON/OFF” to
enter, then briefly press “+” to review the
battery data from b01
→
b04
→
b06
→
b07
→
b08
→
b09
→
b10
→
b11
→
b12
→
b13
→
d00
→
d01
→
d02
→
…
→
dn, then briefly press
”ON/OFF” to exit back to the “Battery Info.”.
Press and hold “+” and “-” synchronously to
save and exit back to the main interface, or
you can also select “BACK”
→
“EXIT” to exit
back to the main interface.
Notice: If the the battery is not a smart bat-
tery, you won’t see any data from battery.
Code
Code definition
unit
b01
Current temperature
℃
b04
Total voltage
V
b06
Average current
A
b07
Remaining capacity
Ah
b08
Full charge capacity
Ah
b09
Relative SOC
%
b10
Absolute SOC
%
b11
Cycle
times
b12
Maximum not charg-
ing time
Hour
b13
Recently not charging
time
Hour
d00
Cell quantity
d01
Voltage of cell 1
V
d02
Voltage of cell 2
V
…
…
V
dn
Voltage of cell n
V