19
6
Error Code Definitions
The DP C10.UART can show e-bike faults. When a fault is detected, the icon will
be displayed. In the speed field one of the following error codes will be displayed:
Error Code
Error Description
Error-shooting Method
“03”
Brake enabled
Check whether a brake cable is stuck
“04”
The throttle has not returned home
Check if throttle has returned home
“05”
Throttle fault
Check the throttle
“06”
Low voltage protection
Check the battery voltage
“07”
Overvoltage protection
Check the battery voltage
“08”
Motor hall signal cable fault
Check the motor module
“09”
Motor phase cable fault
Check the motor module
“11”
Controller temperature sensor failure
Check the controller
“12”
Current sensor failure
Check the controller
“13”
Battery temperature fault
Check the battery
“21”
Speed sensor fault
Check installation position of speed sensor
“22”
BMS communication fault
Replace the battery
“30”
Communication fault
Check the controller connection
Error display
The motor temperature has
reached the threshold.
Note: Error Code 10 will probably appear on the dispaly when the
e-bike is climbling for a long time. This indicates that the motor
temperature has reached the protection value, in which case the
user needs to stop the e-bike for a rest. If the user continues to run
the e-bike, the motor will automatically cut off the power.
“10”
Stop the bicycle until the error code "10"
disappears from the screen.