9
DISPLAY MANUAL
DP C01.UART
PARAMETER SETTING
PARAMETER SETTING
•
Km/mile system setting
After power-on, press the + and - buttons
simultaneously and hold them for three sec-
onds to enter the general setting mode. The
units of the km/mile systems is to be set first.
Press the + or - button to switch between
the km/mile systems. The interface of setting
is shown in the following figure:
•
Speed limit setting
After completing the selection of km/mile
system, press the MODE button to enter
the speed limit setting interface. Press the +
button to increase the speed limit, or press
the - button to decrease the speed limit. Set
range: 15-40; Unit: Km/H. The interface of
setting is shown in the following figure:
Note: when the wheel speed reaches or
surpasses the set value, the output power of
the motor will decline continuously. For the
safety of ride, it is advised to set the speed
limit at 25Km/H and below.
•
Brightness setting
After completing the selection of speed
limit, press the MODE button to enter the
brightness setting interface. Press the +
button to increase the brightness, or press
the - button to decrease the brightness. Set
range: 1-8. The interface is shown in the
following figure:
•
Clock setting - Exiting general settings
After completing the selection of backlight
brightness, press the MODE button to enter
the clock setting interface. Set hours first
(24-hour system). Press the + button to in-
crease the hour value, and press the - button
to decrease the hour value. After completing
the selection of hour value, press the MODE
button to enter the minute setting interface.
Press the + button to increase the minute
value, and press the - button to decrease the
minute value. After completing the selection
of minute value, press the MODE button to
exit the setting interface, which is shown in
the following figure: