Note: after setting the parameters, the
instrument has to be turned off and then
restarted to make the settings effective.
•
Wheel size setting
After power-on, press the + and - buttons
simultaneously and hold them for three
seconds to enter the general setting mode;
release all the buttons; and then press and
hold the + and - buttons and press the
MODE button for eight times to enter the
advanced setting interface. The wheel size
(in inches) is the first to be set. Press the +
button to increase the wheel size, and press
the - button to decrease the wheel size. Set
range: 8-32; Set unit: inch. The interface of
setting is shown in the following figure:
•
Setting of automatic power-off time
After completing the selection of wheel
size, press the MODE button to enter the
automatic power-off time setting interface.
Press the + button to increase the automatic
power-off time, and press the - button to
decrease the automatic power-off time. Set
range: 0-60; Unit: min. When the bicycle
does not move in the set duration, the
instrument will automatically power off and
disconnect the power supply for itself and
the controller. The interface of setting is
shown in the following figure:
Note: if the automatic power-off time is set
to zero, this means the automatic power-off
function is disabled and manual operation is
required for shutdown.
•
Total support level number setting -
Exiting advanced settings
After completing the selection of automatic
power-off time, press the MODE button to
enter the interface for total support level
number setting, in which there are options
for 3/5/9 levels. As shown in the following
figure:
Note: the total support level number does
not include the parking position, i.e. Level 0.
E.g.: if the total support level number is set