UniMod LTE
9
In the UniMod LTE modem an additional slot is available for another inter-
face module. For this slot the following module types are available (installa-
tion: see page 28):
20mA
(CS, current loop) active (for 4 devices max.) or passive;
if the 20mA interface is active it must be operated either with a load or its
terminals must be short-cut.
RS232
(RxD, TxD, CTS, RTS, GND);
RS485
(2 wires);
RS485
(4 wires);
M-Bus
active (for max. 20 devices);
Please note: All interfaces are internally connected with each other. Therefore all
attached devices receive the same data from the interface. It must be