Operating Manual BaehrTec S1200
Page 42/48
English – V100 – Status 09/2015
5.10
Self-help in the event of malfunctions
Fault
Cause
Solution
Control device
without
function
•
Main switch off
•
Control device not
connected to power supply
•
Connecting outlet without
power
•
Mains cable not contacted
correctly (plugged in)
•
Fuse(s) not correct (see
section "Change fuses)
•
Turn on main switch
•
Connect device to power
supply
•
Connect the device to a
functional socket
•
Plug device connector
correctly into the device
socket
•
Check main fuse and
replace if necessary
The device must be
switched off and
disconnected from the
power supply before
checking the fuses.
Fault
Cause
Solution
None
Spray
•
ignored filling level indicator
•
Fine filter in tank clogged
(see section "Care")
•
Filling level contacts soiled
(see section "Care")
•
Regularly check the filling
level indicator, fill up the
spray solution if necessary
•
Change or clean fine filters
The device must
be switched off
and disconnected from
the power supply
beforehand!
•
Cleaning filling level
contacts
Water leaks
from tank or
tank lid when
device upside
down (this is
usually the
case when the
device is
transported
and operated
from a case).
•
Lid is not closed properly.
•
Liquid leaks from membrane
slit
•
Liquid leaks between tank
lid and tank.
•
Screw lid on tight.
•
incorrect spray solution
used.
Attention fire risk!
Membrane not positioned
correctly
•
Check O-rings and replace
as required.