background image

9

C.2.  Electrical connection

Installation

Before working on the unit, switch off  the power supply and secure it 

from being switched on again! Check for the absence of power!

Electrical connections may only be made by a specialist and in compli-

ance with the applicable regulations.

Do not use the controller if the housing shows visible damage, for ex-

ample cracks.

Low-voltage cables such as sensor cables must be routed separately 

from the mains voltage cables. Feed sensor cables into the left-hand 

side of the unit only and mains voltage cables into the right-hand side 

only.

The customer must provide an all-pole disconnecting device in the pow-

er supply of the controller e.g. a heating emergency switch.

The cables being connected to the unit must not be stripped by more 

than 55 mm and the cable jacket must reach into the housing to the 

other side of the strain relief.

Follow the scope of protection according to the German Institut for Standardizations 

VDE 0100-702 for the installation of the controller (distance to the scope of protection

0 and 1).

Danger of electric shock due to improper connection!

-  

Observe VDE and EVU regulations of the energy supply company.

-   Install pumps and swimming pools and their scope of protection

 

according to the German Institut for Standardization VDE 0100-702.

-   Install a disconnecting device for the interruption of the power supply  

 

with min 3 mm of contact per pole.

Danger of electric shock due to voltage on the housing!

-   A correctly confi gured motor overload switch must be installed. 

While doing so, observe the values on the name plate.

-   Protect the power supply with a diff erential switch, nominal residual 

current I ΔN ≤ 30 mA.

-   Only use suitable cables according to regional regulations.

-   Adapt the minimum section of the pipe to the motor capacity and the 

performance range.

-   Provide an emergency stop switch according to DIN EN 809 where 

dangerous situations could arise. The operator should make the 

decision based on this standard.

Summary of Contents for Eco Logic

Page 1: ...Read carefully before installation commissioning and operation Installation and operating instruction Poolregelung BADU Eco Logic ...

Page 2: ...16 3 2 Overview 16 3 3 Alternating 16 3 4 Sleep mode 16 4 Operating mode 17 4 1 Automatic 17 4 2 Manual 17 4 3 Off 17 5 Settings 18 5 1 18 5 2 18 5 3 Filter pump 18 5 3 1 Min hourly filtering time 18 5 3 3 Enable filter pump 18 5 3 4 Clear rinse time 18 5 3 5 Clear rinse stage 18 5 3 6 Clear rinse level V1 19 5 3 8 Daily filtering time 19 5 4 Relay 1 19 5 4 1 Function 19 page 5 4 2 19 5 4 3 19 5 4...

Page 3: ...Specifications on page 5 The valid accident prevention regulations the applicable standards and regulations and the installation and operating instructions of the additional system components must also be observed The controller does not under any circumstances replace any safety devices which are to be provided by the customer Installation electrical connection commissioning and maintenance of th...

Page 4: ...vice for anything other than its intended purpose Operation above or below the limit values listed in the specifications Force majeure A 5 Warranty and liability Changes additions to or conversion of the unit are not permitted without written authorisation from the manufacturer It is likewise forbidden to install additional components that have not been tested together with the unit If it becomes ...

Page 5: ...storage no moisture condensation permitted Other specifications and dimensions Housing design 2 part ABS plastic Installation methods Wall installation optional panel Overall dimensions 163 mm x 110 mm x 52 mm Cut out installation dimensions 157 mm x 106 mm x 31 mm Display Fully graphical display 128 x 64 dots Light diode Multicolor red green Operation 4 entry keys Note for 3 and 1 pumps see below...

Page 6: ...m by means of statistical graphics etc Extensive menu settings with explanations Menu block activation to prevent unintentional setting changes Resetting to factory settings B 3 About the controller Description of controller BADU Eco Logic pool controller 3 pcs 3 5 x 35 mm screws and 3 pcs 6 mm plugs for wall installation 6 strain relief clips with 12 screws replacement fuse 1x T 4 A 250 V BADU Ec...

Page 7: ...system and do not claim to be complete The controller does not replace safety devices under any circumstances Depending on the specific application additional system components and safety components may be required such as check valves non return valves safety temperature limiters scalding protectors etc and must therefore be provided Filter pump control ...

Page 8: ...ng sure not to touch the electric when doing so 4 Hold the lower part of the housing up to the selected position and mark the 3 mouting holes Make sure that the wall surface is as even as possible so that the housing does not become distorted when it is screwed on 5 Using a drill and size 6 bit drill 3 holes at the points marked on the wall and push in the dowels 6 Insert the upper screw and screw...

Page 9: ... scope of protection according to the German Institut for Standardizations VDE 0100 702 for the installation of the controller distance to the scope of protection 0 and 1 Danger of electric shock due to improper connection Observe VDE and EVU regulations of the energy supply company Install pumps and swimming pools and their scope of protection according to the German Institut for Standardization ...

Page 10: ... strain relief devices strip the last 8 9 mm of the wires Fig C 2 1 3 Open the terminals using a suitable screwdriver Fig C 2 1 and make electrical connections on the control ler 4 Refit terminal connection cover and fasten screw 5 Switch on mains voltage and place controller in operation C 2 1 Installation ...

Page 11: ... L R1 Function see page 23 R2 without function R3I without function R3 without function The PE protective conductor must be connected to the PE metal terminal block max 12 V Netzseite 230 VAC D Klemmplan für elektrischen Anschluss Low voltage max 12 VAC DC Terminal Connection for S1 2x without function S2 2x without function Option Temp sensor only display S3 2x without function S4 2x Release cont...

Page 12: ... request for con firmation as to whether the changes which have been made should be saved The function of each of the other three keys 4 is shown in the display line directly above the keys the right hand key generally has a confirmation and selection function The LED 2 lights up when a solar request is active Ball value on off Other features of the LED are discribed in chapter Z 1 Examples of key...

Page 13: ...y the menu 4 2 Manual on page 18 should be used to test the switch outputs with the consumers connected and to check the sensor values for plausibility Then the automatic mode can be switched on Automatikbetrieb einzuschalten The first time the controller is turned on and after the language and time are set a query appears as to whether you want to param etrise the controller using the commissioni...

Page 14: ...ol of the system with opera ting hours etc Select graphics mode or overview mode Automatic mode manual mode or switch unit off Set parameters needed for normal opera tion Solar and frost protection anti seizing protection etc Clock factory settings etc Against unintentional setting changes at critical points For diagnosis in the event of an error Language selection Operation 2 Statistics 3 Display...

Page 15: ...rrectly or overwritten The manufacturer accepts no liability for the recorded data 2 1 Operating hours Display of operating hours of the pump connected to the controller various time ran ges day year are available 2 2 2 3 2 4 Graphic overview This provides a clearly organised display of the above mentioned data as a bar graph Various time ranges are available for comparison The two left hand keys ...

Page 16: ...lay mode 3 1 Schematic In graphics mode the selected hydraulic systems are depicted with operating states of the connected consumers 3 2 Overview In overview mode the operating states of the connected consumers are depicted in text form 3 3 Alternating 3 4 Sleep mode In alternating mode the schematic mode and then the overview mode are active for 5 seconds at a time When active the display s backl...

Page 17: ... of the mains voltage the controller automatically returns to the last operating mode selected 4 1 Automatic Operating mode 4 2 Manual The relay and thus the connected consumer are switched on and off with no regard to the parameters which have been set by pressing a key 4 3 Off When the operating mode Off is activated all controller functions are switched off When the operating mode Manual is acti...

Page 18: ...ration 5 3 1 Min hourly filtering time This menu is used to set the hourly filtering time The pump is switched on at the end of the hour for the set time Setting range off 1 min 60 min Default off 5 3 2 5 3 3 Enable filter pump In this menu the setting for enabling the filter pump via the sensor input S4 can be made In addition the clear rinse time and the clear rinse level can also be set for Eas...

Page 19: ...o mode if the solar unit or the auxiliary heating runs the filter then also runs these operating hours will be subtracted from the filtering times set here Setting range off daily 0 00 23 59 Default daily 16 00 21 00 Relay 1 5 4 1 Function The function for relay 1 is set here Setting range Deactivated Timer Thermostat Default Deactivated 5 4 4 Times If the time function is selected the daily switc...

Page 20: ... the relay in question and the con nected consumer on every day at 12 00 setting daily or weekly on Sundays at 12 00 setting weekly for 5 seconds in order to prevent the pump and or the ball valve or other consumer from sticking after an extended stationary period Setting range R1 daily weekly off Default off Setting range R2 daily weekly off Default off 6 1 Seizing protection This does not under ...

Page 21: ...ioning in the correct order and provides brief descriptions of each parameter in the display Pressing the esc key takes you back to the previous value so you can look at the se lected setting again or adjust it if desired Pressing the esc key more than once takes you back to the selection mode thus cancelling the commissioning help See also E 2 Commissioning help on page 13 7 4 Commissioning May o...

Page 22: ...g range impulse permanent Default impulse 7 9 Signal mode Alternativly to a multistage pump a variable speed pump can be connected at output V1 via a frequency converter and controlled via a 0 10 V signal The pump works in a linear fashion between 0 V pump off and 10 V 100 pump capacity 7 10 0 10 V Signal The value set here appears if the multistage pump runs at level 1 Setting range 1 100 Default...

Page 23: ... 7 2 Time and date 8 Menu lock 9 Service values To lock the other menus select Menu lock on To enable the menus again select Menu lock off Setting range on off Default off Menu lock The menu 8 Menu lock can be used to secure the controller from unintentional changing of the set values The menu is closed by pressing the esc key or selecting Exit menu lock 8 Menu lock ...

Page 24: ...ressing the esc key Service data 9 Service data Enter the values at the time when the error occurs e g in the table 10 Language The menu 10 Language can be used to select the language for the menu guidance This is queried automatically during initial commissioning The choice of languages may differ howe ver depending of the device design Default Deutsch Language ...

Page 25: ...present the warning symbol changes to an info symbol and the red light no longer flashes To obtain more detailed information on the error press the key under the warning or info symbol Possible error messages Notes for the specialist Restart Means that the controller was restarted for example due to a power failure Check date and time Do not try to deal with this yourself Consult a specialist in th...

Page 26: ...g on the unit switch off the power supply and secure it from being switched on again Check for the absence of power Only use the spare fuse supplied or a fuse of the same design with the following specifications T 4 A 250 V Z 2 Replacing the fuse Z 2 1 Performing maintenance Check the time and date see 7 2 Time and date on page 26 Assess check plausibility of analyses see 2 Statistics on page 16 C...

Page 27: ...hod for remote diagnosis Write the service values down 9 Service values on page 31 at the time the suspected malfunction occurs Send the service value table by fax or e mail with a brief description of the error to the specialist or manufacturer To protect against loss of data record any analyses and data that are particularly important to you see 2 Statistics on page 16 at regular intervals Filte...

Page 28: ...28 ...

Page 29: ...29 ...

Page 30: ...30 Commissioner s notes ...

Page 31: ...tions have been created with the greatest possi ble care the possibility of incorrect or incomplete information cannot be excluded Subject as a basic principle to errors and technical changes Hydraulic variant set Commissioned on Commissioned by ...

Page 32: ... Here you will find further FAQs and notes regarding the BADU Eco Logic ...

Page 33: ...r for the control is activated and retains the date and time for min 24 hours There are no guarantees that the date and time will be retained for disruptions exceeding this time frame However it is possible All other settings remain unchanged even without the charging capacitor ...

Page 34: ...hole can be drilled into the low voltage side to insert the switch IPx4 in order to avoid installing an extra housing A d 6mm drill should be used The hole should be positioned as shown to the right 10 6mm 5 3mm Article 5880800212 Kippschalter 5880800213 Kappe für Kippschalter 5811250600 Beilagscheibe ...

Page 35: ...a tensione 2014 35 EU EG laagspanningsrichtlijn 2014 35 EU EU pienjännitedirektiivi 2014 35 EU directiva de baja tensión 2014 35 UE Dyrektywa niskonapięciowa 2014 35 UE nízkonapěťová směrnice 2014 35 EU nízkonapäťová smernica 2014 35 EU EF lavspændingsdirektiv 2014 35 EU EG lågspänningsdirektivet 2014 35 EU AT Alçak Gerilim Yönetmeliği 2014 35 EU Директива ЕС по низким напряжениям 2014 35 EU EMV R...

Reviews: