Badger Meter Recordall RET Installation & Operation Manual Download Page 4

Operation

The RET™ is shipped pre-programmed with  preset default values
for  the specific meter it will be used on or with specific  values
requested by the customer.  In either case, the programmed values
can be viewed on the display along with totalization and rate of flow
values.

To view the seven different values on the display simply touch the
programming magnet that came with the RET to the side of the
register as shown in figure A below.

Figure A

The display will cycle through the following information “screens”
when activated by an external magnet.  During the activation pro-
cess, there is a one second delay before the display can be ad-
vanced again.  This delay is designed to avoid inadvertent skips
in the visual display.  The totalization and flow rate information
are continuosly updated as the display is being viewed.

Note:  When the scaled output and 4-20mA flow rate outputs are
not used the corresponding “screens” will not be shown.

1.

totalization

2.

rate of flow

3.

meter type and size

4.

high resolution test mode

5.

back flow totalization

6.

scaled pulse resolution

7.

20 mA set point

1.

Totalization:  Meter consumption is shown as a 6 digit num-
ber.  Depending on the test circle value one of the multiplier
values will also be shown (X10, X100, X100, X1,000,
X10,000).  If the test circle is less than 1 then a decimal point
will be used.  The unit of measure will also be displayed
(GAL, FT3, M3, IMP, LITER).

2.

Rate of Flow:  Rate is shown as a 5 digit display without a
multiplier.  The unit of measure (GAL, FT3, M3, IMP, LITER)
will be shown with the corresponding time unit (per MIN, per
HOUR).  The flow rate resolution will vary with meter size.
There are no multipliers used for flow rate.  Flow in the re-
verse direction is displayed with a negative sign.

3.

Meter information:  This screen identifies the meter for which
the transmitter was programmed.  The information shown
will be the meter type (TURBO, DISC, COMP), unit of measure
(GAL, FT3, M3, IMP, LITER) and the 6 digit display that will
uniquely identify the meter.  Disc meters are indicated by a d,
Turbo meters are indicated by a r and Compound meters are
indicated by a C. The example below shows a 3" Turbo Se-
ries meter calibrated in gallons.

4.

Test mode:  This screen is identical to the totalization screen
except for the resolution.  The TEST annunciator is used to
identify this mode.  In the test mode the resolution is in-
creased by a factor of 1000 to obtain accurate test results.
For example, if the usage on the totalization screen 123456
gallons X 100 or 12,345,600 gallons then in the test mode the
multiplier would move the display 3 decimal places to the
right and show the actual values of the last three digits.  The
display would then show TEST 45678.9 GAL.

5.

Backflow:  This screen is identical to totalization except it is
only 5 digits preceded by a negative sign.   The negative
sign indicates the backflow screen.  The resolution of the
backflow screen is the same as in the test mode. The
backflow screen shows the total amount of reverse flow
through the meter.

Recordall

Electronic

Transmitter

64001-002

Digital & 4-20 mA Outputs

0501

Badger Meter

®

M

ag

ne

t

To change the
display, touch
magnet here

45678.9

TEST

GAL

-0012.3

GAL

perMIN

123

GAL

4

123456

X100

GAL

4

0  450

GAL

TURBO

Summary of Contents for Recordall RET

Page 1: ...BadgerMeter Inc Installation Operation Manual Model RET Recordall Electronic Transmitter Providing Unscaled Scaled Optional 4 20 mA Outputs RET IOM 1 P N59322 033 2 02...

Page 2: ...complete with both a scaled open collector and unscaled open collector output signal The product is also offered with an optional 4 to 20 mA output providing a rate of flow signal The Recordall Elect...

Page 3: ...with the short alignment mark up and position the band so that the long alignment mark is lined up with the alignment mark at the base of the female connector 2 Insert the male connector into the fem...

Page 4: ...LITER will be shown with the corresponding time unit per MIN per HOUR The flow rate resolution will vary with meter size There are no multipliers used for flow rate Flow in the re verse direction is d...

Page 5: ...ic interface circuit used to program and read the parameters of the Recordall Electronic Transmitter RET The RET Programmer is powered by a stan dard 9 volt alkaline battery Connection from the RET Pr...

Page 6: ...ove the pointer to the desired box Click the left mouse button to place the cursor in the box Use the backspace key to erase the existing number and use the keyboard to input a new number After the pa...

Page 7: ...d range the user will be notified when the operator attempts to program the RET The message will be The Set Point value entered was not within limits of 50 to 120 Numeric Limits are ____ to ____ and t...

Page 8: ...ring 2 Check connections Troubleshooting Ctrl Alt Delete keys simultaneously and shut off the appropriate applications The computer screens of the RET Programmer can be printed to provide a copy of th...

Page 9: ...0 0 6509 310 0000 3 0733 TSM 200 200 ft3 10 1 0 1 1 0 0871 41 4408 22 9999 TSM 200 200 m3 1 0 01 0 01 0 1 0 0026 1 1737 812 7840 TSM 200 200 IMP 100 10 1 10 0 542 258 1463 3 6906 TSM 200 200 liter 100...

Page 10: ...47 104712 4000 CSM 3 H C400H IMP 100 10 1 10 0 6246 375 0000 3 8440 CSM 3 L C400L IMP 10 1 0 1 1 0 0348 20 8183 476 2456 CSM 3 H C400H liter 100 100 1 10 2 84 1700 0000 0 8440 CSM 3 L C400L liter 10 1...

Page 11: ...4 64 4396 8144 0 0812 turbo II 10 II 10 liter 1000 100 1 100 100 19990 6080 0 0179 turbo II 12 II 12 gal 10000 100 1 1000 37 38 6600 0000 0 0535 turbo II 12 II 12 ft3 1000 10 1 100 4 997 882 2880 0 40...

Page 12: ...ng bid obligation exists Copyright BadgerMeter Inc 2002 Allrightsreserved alldatasubjecttochangewithoutnotice Please see our website at www badgermeter com for specific contacts BadgerMeter Inc P O Bo...

Reviews: