background image

5

License Requirements

This device complies with Part 15 of FCC
Rules. Operation of this device is subject to
the following conditions: (1) This device may
not cause harmful interference, and (2) this
device must accept any interference received,
including interference that may cause
undesired operation.

No FCC license is required by a utility to
operate a Badger ORION meter reading
system.

Any changes made, but not approved by
Badger Meter, can void the user’s authority to
operate the equipment.

Note Explanations

NOTE:

 

Communicates installation, operation, or

maintenance information that is safety related but
not hazard related.

Scope of Manual

This manual contains installation instructions
for mounting the 

Badger

®

 ORION

®

 Integral

Transmitter for Gas Meters

 on two American

Gas Meters.

Proper performance and reliability of the
Badger ORION system depends upon
installation in accordance with these
instructions.

Product Unpacking and Inspection

Upon receipt of the product, perform the
following unpacking and inspection
procedures:

NOTE:

 

If damage to the shipping container is

evident upon receipt, request the carrier to be
present when the product is unpacked.

Carefully open the shipping package, follow
any instructions that may be marked on the
exterior.  Remove all cushioning material
surrounding the product and carefully lift the
product from the package.

Retain the package and all packing material
for possible use in reshipment or storage.

Visually inspect the product and applicable
accessories for any physical damage such as
scratches, loose or broken parts, or any other
sign of damage that may have occurred
during shipment.

NOTE:

 

If damage is found, request an inspection

by the carrier’s agent within 48 hours of delivery
and file a claim with the carrier. A claim for
equipment damage in transit is the sole
responsibility of the purchaser.

Summary of Contents for Orion 64989-002

Page 1: ...em ORION Transmitter for American Commercial Meters IMPORTANT This manual contains important warnings and information READ AND KEEP FOR REFERENCE After Installation of ORION Transmitter After Installa...

Page 2: ...d or compromise safety Questions or Service Assistance If you have questions regarding the product or this document contact Badger Meter Inc P O Box 245036 Milwaukee WI 53224 9536 Telephone 414 355 04...

Page 3: ...Seal Security Screw and Dial Index 7 Badger ORION Model 64989 002 7 Index and Index Cover Plate Removal from American Meter 7 Badger ORION Transmitter Label 8 Install Badger ORION Transmitter and Amer...

Page 4: ...4 Thispageintentionallyleftblank...

Page 5: ...Badger ORION system depends upon installation in accordance with these instructions Product Unpacking and Inspection Upon receipt of the product perform the following unpacking and inspection procedu...

Page 6: ...his manual describes the installation on an American Commercial Diaphragm and Turbine Meter with Wire Seal Security Screws The second section of this manual describes the installation on an American C...

Page 7: ...ep 1 Remove the wire security seal from the index cover mounting screw Step 2 Use a large screwdriver to remove the four 4 18 8 index cover mounting plate screws and American Index Discard the four sc...

Page 8: ...new serial number tag above the one that is on the transmitter Step C Place the cover plate back on the transmitter Badger ORION Transmitter Label If the utility chooses to add an additional label fol...

Page 9: ...of the cover mounting plate Use four 4 18 18x3 1 2 supplied mounting screws to attach the index cover plate and Badger ORION transmitter to the gas meter Washer Step 7 Tighten all screws evenly with...

Page 10: ...ter with Wire Seal Security Screw converted to seal caps If the index mounting seal caps were removed replace them with the extra caps provided in the installation kit Complete the Installation After...

Page 11: ...Discard the four screws Step 2 Remove the American index and mounting plate AMERICAN Commercial Diaphragm and Turbine Meters with Red Security Seals American Commercial Diaphragm and Turbine Meter wit...

Page 12: ...for disengagement Test to ensure the pawls are engaged and moving freely Install the Badger ORION Transmitter and American Cover Plate Use care when handling the Badger ORION transmitter to insure th...

Page 13: ...ounting screws and a washer on each to attach the index cover plate and Badger ORION transmitter to the gas meter Washer Step 3 Be sure the gas INLET markings are on the same side of the meter and the...

Page 14: ...gm and Turbine Meter with Red Security Seals If the index mounting screw seal caps were removed replace them with the extra caps provided in the installation kit Complete the Installation After progra...

Page 15: ...15 This page is intentionally left blank...

Page 16: ...the extent an outstanding contractual obligation exists BadgerMeter Inc P O Box 245036 Milwaukee WI 53224 9536 Telephone 414 355 0400 877 243 1010 Fax 414 355 7499 866 613 9305 www badgermeter com Cop...

Reviews: