LM_MDS2000_BA_02_0810
Troubleshooting Page
26/44
3 Count error: Missing pulse in quadrature pulsers only
4 It means that the power has been shut down during the transaction:
Power down
5 The transaction has been stopped by the emergency procedure ("..."):
System inactive
6 IOP error: Microprocessor error
7 Unauthorised transaction: For approved systems only, quantity dispensed
between 0,5 Lt and 100 Lt.
1.5.8 Procedure to change the battery
- Test of the microprocessor supervisory circuit "MAX690" next to the
battery:
- With power 24 VDC: Pin 3 (-) Pin 7 (+) = 5 VDC
- Without power 24 VDC: Pin 4 (-) Pin 8 (+) = 3 VDC (2 VDC MIN)
- Print a diagnostic and your reports by security.
- Under tension, remove the battery and replace it by a new one.
2. Software manual
2.1. Program license agreement
Before opening the software envelopes, please read the terms of the following
license agreement carefully.
You signify your acceptance of the terms of this agreement by opening the
envelopes.
If you do not agree with them, you should promptly return the package.
Article 1: License grant
We grant you a license:
1. To use the program in a single machine
2. To make archival back-up copies of the program in support of your use of the
single program on a single machine
3. To transfer the program to another party if that party agrees to accept the terms
and conditions of this agreement and you do not retain any copies of the
program, whether in printed or machine-readable form. Except as expressly
provided for in this license, you may not copy, modify or transfer this program.
Article 2: Term
This license is effective until terminated. You may terminate it at any time by
destroying the program together with all its copies in any form. It will also terminate
upon conditions set forth elsewhere in this agreement. You agree, upon such
termination, to destroy the program together with all copies in any form.