Network
Page 20/44
The following operations must be executed depending on the different
installation configurations.
We recommend to structure the dialog of the network before connecting the
pulse transmitters and the solenoids to the I/Os.
1.4.4 Level
1
Installation with 1 I/O unit, maximum 8 keypads and without PC.
- All the I/O units are delivered with the ID Nr. 0, don't modify it.
- All the keypads are delivered with the ID Nr. 1. A different ID Nr. must be
given to each keypad.
- All the displays are delivered with the ID Nr. 0. A different ID Nr. must be
given to each different display.
Procedure to change the address of the keypad (ID):
This procedure must be done from each keypad.
At power up, all the keypads will show:
1. Remove all the keypad's connectors or shut-off the power
2. Press the key "Space" on the keypad you need to change and hold down
3. Put back the connector or power on
4. Release the "space key": the screen will show: ID ?
5. Type in the keypad ID Nr. (0 to 7)
6. Press enter
Execute the same procedure with different ID Nr. for all the keypads. On
every keypad, you have to give and address for the ticket A& B printer
setup.
When all the keypads will be correctly identified by the network, they will all
show "PIN".
N.B.: If your installation contains one L2061 network gate for long distance
printer, please note the ID "0" is reserved to this device.
Procedure to change the address of the display (ID):
1. Remove the displays' connector or shut off the power
2. Change the address (see schema)
3. Put back the connector or power on
4. The good display's identification can be checked via the software in test C
VERSION
n°
#.##
I.D.: X
Version Date
(X is the address of the keypad)