![Badger Meter B131-038 Manual Download Page 10](http://html1.mh-extra.com/html/badger-meter/b131-038/b131-038_manual_3507559010.webp)
Specifications
Page 10
April 2016
TRB-UM-00372-EN-03
SPECIFICATIONS
Materials of
Construction
Body and Internal
Wetted Parts
316 stainless steel
Rotor
CD4MCU stainless steel
Bearings
Tungsten carbide
Rotor Shaft
Tungsten carbide
Operating
Limitations
Temperature
–150…350° F (–101…177° C)
The meter should not be subjected to temperatures above
350° F (177° C), or below –150° F (–101° C) or the freezing point
of the metered liquid�
Pressure
Flange Rating
(ANSI)
150# 300# 600# 900# 1200#
Working Pressure psi
285
740
1480
2220
3705
Working Pressure
MPa
1�97
5�1
10�2
15�31 25�55
*Test Pressure (psi)
427�5 1110
2220
3330 5557�5
*Test Pressure (MPa)
2�95
7�65
15�31 22�96 38�32
* Test pressure based on 1�5 safety factor�
Accuracy
1�0% of reading
Repeatability
± 0�1%
Calibration
Water (NIST Traceable Calibration)
Corrosion
Constructed of stainless steel and tungsten carbide� The
operator must ensure that the operating fluid is compatible
with these materials� Incompatible fluids can cause
deterioration of internal components and cause a reduction in
meter accuracy�
Pulsation and
Vibration
Severe pulsation and mechanical vibration will affect accuracy
and shorten the life of the meter�
Figure 4: Typical cross-section of models B131-038…B131-100