SPECIFICATIONS

Sensor 

Assembly:    

 

Housing:  PEEK   

 

 

Impeller:  316SS   

 

 

Shaft:  Tungsten Carbide

 

CS Specific: Torlon

®

 Bearing, EDPM O-Rings

 

HS Specific:  Ketron

®

 Bearing, Aflas

®  

O-Rings

Tee: 

Cast Bronze

    

ENVIRONMENTAL    

Fluid Temp.  

-4°F to 140°F (-20°C to 60°C) - chilled

 

 

40°F to 260°F (4°C to 125°C) - hot 

Ambient Temp.   -4°F to 150°F (-20°C to 65°C) 

 

 

Pressure Ratings:

Badger Data Industrial Series 380 BTU Systems

Specifications

MECHANICAL

Sensor Assembly

Mass

< 15lb

Houseing:  PEEK

Impeller:  316SS

ELECTRICAL

Shaft:  Tungston Carbide

Inputs

CS Specific: Torlon Bearing, EDPM O‐Rings

Power

12‐35VDC

HS Specific:  Ketron Bearing, Aflas O‐Rings

9‐28VAC rms

Communication Modbus

Tee

BACnet

Cast Bronze

Output

Scaled Pulse Open Drain

Temperature Rating For Wetted Materials

CS:  ‐20F to 180F

MATERIALS

HS:  30F to 250F

Housing

Polycarbonate

Flow Sensor PEEK

Ambient Temperature Rating

Potting Material Polyurethane

‐20C to 65C

Tee

Brass

Pressure Ratings

Sensor Body Sizes

Tee Sizes 0.75", 1", 1.25", 1.5", and 2"

Recommended Design Flow Range

1 to 15 FPS

380CS and 380HS*

Temp** F

Temp F

PSIG

Type

Range

COMMENTS

40

400 380CS

-20 > +180

Torlon Brgs & EPDM seals

60

400 380CS

-20 > +180

Torlon Brgs & EPDM seals

80

400 380CS

-20 > +180

Torlon Brgs & EPDM seals

100

380 380CS

-20 > +180

Torlon Brgs & EPDM seals

120

365 380CS

-20 > +180

Torlon Brgs & EPDM seals

140

350 380CS

-20 > +180

Torlon Brgs & EPDM seals

160

340 380CS

-20 > +180

Torlon Brgs & EPDM seals

180

320

380CS

-20 > +180

Upper Limit for Torlon & EPDM

200

300 380HS

+30 > +250

Ketron Brgs & Aflas seals***

220

280 380HS

+30 > +250

Ketron Brgs & Aflas seals

240

260 380HS

+30 > +250

Ketron Brgs & Aflas seals

250

230 380HS

+30 > +250

Ketron Brgs & Aflas seals

*Rating is based on PvT of Brass RTD fitting.

**Non-Freezing.

***Special: Ketron Brgs & EPDM seals for < +30F.

Accuracy

Flow Calculation:  ±1% of Rate

Temperature Calculation:  ±1% 

BTU Calculation:  ±1% 

Output Pulse Width

10, 50, 150, 200, or 250mS

Put Image of Dimentional Drawing here

380CS and 380HS*

Temp** F

Temp F

PSIG

Type

Range

COMMENTS

40

400 380CS

-20 > +180

Torlon Brgs & EPDM seals

60

400 380CS

-20 > +180

Torlon Brgs & EPDM seals

80

400 380CS

-20 > +180

Torlon Brgs & EPDM seals

100

380 380CS

-20 > +180

Torlon Brgs & EPDM seals

120

365 380CS

-20 > +180

Torlon Brgs & EPDM seals

140

350 380CS

-20 > +180

Torlon Brgs & EPDM seals

160

340 380CS

-20 > +180

Torlon Brgs & EPDM seals

180

320

380CS

-20 > +180

Upper Limit for Torlon & EPDM

200

300 380HS

+30 > +250

Ketron Brgs & Aflas seals***

220

280 380HS

+30 > +250

Ketron Brgs & Aflas seals

240

260 380HS

+30 > +250

Ketron Brgs & Aflas seals

250

230 380HS

+30 > +250

Ketron Brgs & Aflas seals

*Rating is based on PvT of Brass RTD fitting.

**Non-Freezing.

***Special: Ketron Brgs & EPDM seals for < +30F.

Figure 7:  380 CS & HS Pressure Ratings

MECHANICAL

 

Mass:  Less than 13 lbs.

ELECTRICAL

Inputs

 

Power:  Isolated 12-24 V DC/V AC ±10% 

 

 

 

RS-485 is non-isolated to prevent ground faults. Do not share power with other devices.

 

 

Badger Meter A1028 plug-in type 120 VAC/12 V DC power supply recommended.

 

Communication: Modbus RTU 

   BACnet 

MSTP 

Output

 

Scaled Pulse: 

Open Drain

 

 

 

0.01 Hz min. to 100 Hz max. 

 

MATERIALS

 

Housing: 

Polycarbonate  

 

Flow Sensor: 

PEEK 

 

 

Potting Material: Polyurethane 

 

 Tee: 

 Brass 

 

    

Summary of Contents for 380CS

Page 1: ...Series 380 Impeller Btu System 380CS HS Installation Operation Manual PN 880102 0001 Rev 4 7 11 IMPORTANT This manual contains important information READ AND KEEP FOR REFERENCE...

Page 2: ...Series 380 Impeller Btu System Page ii 7 11...

Page 3: ...ION 6 COMMISSIONING 7 RS 485 Network Configurations 8 RS 485 Network Configurations Modbus 8 RS 485 Network Configuration BACnet 9 SPECIFICATIONS 11 MECHANICAL 11 ELECTRICAL 11 Inputs 11 Output 11 MAT...

Page 4: ...Series 380 Impeller Btu System Page iv 7 11...

Page 5: ...nnection Setup includes energy measurement units measurement method communications protocol pulse output option fluid density and specific heat parameters Cold Service 380CS Designed for operating in...

Page 6: ...low flow rates Any circumferential location is correct for installation in vertical pipes Rising flow is preferred to reduce effects of any trapped air Installing the Sensor Tee 1 Position the tee for...

Page 7: ...f Zero parameter is the difference between T1 and T2 that will still read 0 energy rate If the Scaled Pulse Output is going to be used the user can select what the pulse is representing Energy or Flow...

Page 8: ...ode RTU or ASCII The Series 380 uses IEEE 754 Float Data Located in Read Holding Registers The Series 380 Data Format is Float 32 where the Data is stored across two Read Holding Registers In the case...

Page 9: ...Float Read Only Temp Coef 40017 40018 IEEE 754 Float Read Only Specific Heat 40019 40020 IEEE 754 Float Read Only Fluid Density 40021 40022 IEEE 754 Float Read Only RS 485 Network Configuration BACne...

Page 10: ...n Analog Value AV10 SerialNum dimensionless BACnet Protocol Implementation Conformance Statement BACnet Standardized Device Profile Device Profile Tested BACnet Smart Actuator B SA Supported BIBBs Sup...

Page 11: ...200 300 380HS 30 250 Ketron Brgs Aflas seals 220 280 380HS 30 250 Ketron Brgs Aflas seals 240 260 380HS 30 250 Ketron Brgs Aflas seals 250 230 380HS 30 250 Ketron Brgs Aflas seals Rating is based on...

Page 12: ...m Sensor Body Sizes Tee Sizes 0 75 1 1 25 1 5 and 2 NPT Recommended Design Flow Range 1 to 15 FPS Accuracy Flow Calculation 2 of flow rate within flow range 0 5 Repeatability RTD Meets IEC751 Class B...

Page 13: ...Page 13 7 11 Installation Operation Manual Intentional Blank Page...

Page 14: ...e to continuous research product improvements and enhancements Badger Meter reserves the right to change product or system specifications without notice except to the extent an outstanding contractual...

Reviews: