background image

• KEEP THE FIRE COLUMN OUT OF THE WEATHER

    AND ELEMENTS.

• STORE THE FIRE COLUMN IN A DRY LOCATION

    OUT OF THE WEATHER.

• DO NOT LET THE BASE WITH ASH CATCHER FILL

    WITH WATER.

• DO NOT DUMP ASHES WHERE A FIRE CAN BE

    STARTED.

• DISPOSE OF ASHES IN PROPER RECEPTACLE ONLY

    AFTER ASHES HAVE COOLED.

• USE ANY COVER ONLY AFTER THE FIRE COLUMN

    IS COMPLETELY COOL TO THE TOUCH.

• STORE THE FIRE COLUMN IN AN AREA SO THAT IT

    WON'T BE PRONE TO TIPPING OVER AND BEING

    A HAZARD.

HELPFUL HINTS:

Congratulations on your purchase of the Fire 

Column!   At Landmann USA, we strive to provide 

you with an easy to use, easy to assemble product.  

However, in the unlikely event your package 

should have a missing or defective part, please 

contact us at:   

[email protected]

Proof of purchase may be required.   Thank you!

©2019

Distributed by Menard, Inc.

Eau Claire, WI   54703

Made in China

MODEL:   259-5165

MANUFACTURER MODEL:   21109

AVAILABLE ACCESSORIES

FOR THE FIRE COLUMN

These custom made accessories are

made just for the Fire Column.

COVER

MODEL 29501

For questions or comments please

Email customer service at:

[email protected]

ALL SURFACES

BECOME HOT

DURING USE!

!

!

PAGE 14

!

!

MULTI-PURPOSE

37 IN. POKER

MODEL 29240

For best results, the Fire Column should be 

cleaned after every use.   Make sure Fire Column 

is cool and all embers are extinguished before 

cleaning.

Clean off the ash catcher with shovel or by tilting 

the Fire Column to one side and removing the 

ash.

If any remaining firewood needs to be removed, 

turn the Fire Column on its side to remove.

Dispose of ashes in proper receptacle only after 

ashes have cooled.   Do not dump ashes where a 

fire can be started.

If the Fire Column needs to be cleaned, use a 

mild soap and water with a soft rag.   Dry 

thoroughly to prevent rust.

Occasionally, the Fire Column finish will need to 

be refinished.   Use a high quality, high heat 

paint to renew the finish.

  CLEANING

FIRE COLUMN

NEVER USE GASOLINE,
ALCOHOL OR  VOLATILE 
FLUIDS TO  START OR 
RESTART FIRES.

WARNING!

!

HOT!

!

WARNING!

!

HOT  SURFACES DURING USE! 

Summary of Contents for 259-5165

Page 1: ...VER 1 12 12 2018 Assembly and Use Instructions PLEASE READ ALL RULES FOR SAFE OPERATION AND HELPFUL HINTS BEFORE USING 259 5165 FIRE COLUMN...

Page 2: ...TO EMPTY THE ASHES IN THE BASE OR COLUMN UNTIL THE FIRE COLUMN HAS COMPLETELY COOLED THE OUTDOOR FIREPLACE IS FOR ADULT USE ONLY DO NOT LEAVE UNATTENDED AT ANY TIME WHILE IN USE DO NOT MOVE THE FIREP...

Page 3: ...ges PARTS LIST 1 BASE WITH ASH CATCHER A 1 BOTTOM PLATE D 2 STRUCTURED PANEL B 2 SLIDING PANEL C 4 M5 x 15MM SHOULDER BOLT M 4 M5 WINGNUT N 8 M6 x 15MM BOLT P 4 M6 HEXNUT Q 4 18MM FLAT WASHER R x 4 x...

Page 4: ...the notched corner of the bottom plate will fit around the angled side of the structured panel Assemble using 2 15MM bolts P and 2 hexnuts Q Hand tighten only FIRE COLUMN ASSEMBLY INSTRUCTIONS 1 8 PA...

Page 5: ...ith the pins on the sliding panel C Slide panel to lock in place Make sure all pins align and attach PAGE 5 FIRE COLUMN ASSEMBLY INSTRUCTIONS 2 8 2 STEP B C PIN SLOT DO NOT RETURN PRODUCT TO THE STORE...

Page 6: ...panel C Slide panel to lock in place Make sure all pins align and attach PAGE 6 FIRE COLUMN ASSEMBLY INSTRUCTIONS 3 8 B C PIN SLOT 3 STEP DO NOT RETURN PRODUCT TO THE STORE IF YOU HAVE QUESTIONS OR HA...

Page 7: ...2 hexnuts Q Tighten all 4 bottom panel bolts securely PAGE 7 FIRE COLUMN ASSEMBLY INSTRUCTIONS 4 8 P Q M6 x 15MM BOLT P M6 HEXNUT Q x 2 x 2 4 STEP B D DO NOT RETURN PRODUCT TO THE STORE IF YOU HAVE QU...

Page 8: ...e panel down to lock in place Make sure all pins align and attach Don t pinch fingers between the panels PAGE 8 FIRE COLUMN ASSEMBLY INSTRUCTIONS 5 8 CAUTION C PIN SLOT 5 STEP DO NOT RETURN PRODUCT TO...

Page 9: ...ad 4 wingnuts to the shoulder bolts to lock all panels in place Tighten wingnuts securely PAGE 9 FIRE COLUMN ASSEMBLY INSTRUCTIONS 6 8 6 STEP M N M N M5 x 15MM SHOULDER BOLT M M5 WINGNUT N x 4 x 4 Mak...

Page 10: ...ivet nuts Assemble using 4 15MM bolts P and 4 flat washers R Tighten bolts securely PAGE 10 FIRE COLUMN ASSEMBLY INSTRUCTIONS 7 8 M6 x 15MM BOLT P 18MM FLAT WASHER R x 4 x 4 P R A 7 STEP DO NOT RETURN...

Page 11: ...e ground The Fire Column is ready for use PAGE 11 FIRE COLUMN ASSEMBLY INSTRUCTIONS 8 8 8 STEP 20 40 12 DO NOT RETURN PRODUCT TO THE STORE IF YOU HAVE QUESTIONS OR HAVE TROUBLE WITH ASSEMBLY PLEASE EM...

Page 12: ...PS Use smaller pieces of firewood instead of large pieces Use firewood and fuel up to 14 inches in length and no larger than 3 5 inches in diameter Hardwoods will burn longer and provide nicer fires t...

Page 13: ...ow firewood into the column Do not overfill the column Do not burn firewood on the base Do not place or burn firewood on top of the column Avoid behavior that could cause the Fire Column to tip over K...

Page 14: ...SSORIES FOR THE FIRE COLUMN These custom made accessories are made just for the Fire Column COVER MODEL 29501 For questions or comments please Email customer service at customerservice landmann usa co...