D-BA-0000308.6.4
Technical data and dimensional drawings Operating
instructions
OI-42
V05 / September 07, 2010
Ambient conditions
Operating
temperature
Table 20 ''Operating temperature IPC312'', Page OI
-
Tested according to EN60068-2-14 (test Na and Nb) and UL508
This value refers to an ambient temperature measured at a
distance of 10 cm to front, rear, top and bottom side, in quiet air and
without exposing the device to any heat radiation.
Storage temperature
-20 to +60 °C
Tested according to EN60068-2-2 (test Bb) and EN60068-2-1 (test
Ab)
Relative humidity
5 to 95 %, without condensation
Tested according to EN60068-2-27 (test Ea)
Half-sine
15 g, 11 ms duration
Resistance to shocks
2 shocks per axis in all three directions
Tested according to EN60068-2-6 (test Fc)
10 Hz to 57 Hz, 0.075 mm excursion
Sinusoidal
58 Hz to 150 Hz with max. 1.0 g acceleration
1 octave/minute (±10%)
Resistance to
vibrations
Sweep rate
10 sweep cycles per axis
Pollution degree
2
Tab. 19: Ambient conditions IPC312