Bacharach PUR-CHEK Operation And Maintenance Manual Download Page 5

Pur•Chek

Instruction 2100-9000

1

1 Introduction

1.1  How to Use This Manual

This manual provides important information on how to operate and maintain Bacharach’s Pur•Chek

 HVAC 

Advanced Refrigerant Identifi er.

To assure operator safety and proper use of the Pur•Chek

, please read, understand, and follow the contents of 

this manual.

1.2  Warnings & Cautions

When used in this manual or as labeled on the Pur•Chek™, the following hazard symbols and/or associated 
words are defi ned as follows:

WARNING:

 This symbol and/or the use of the word 

WARNING

 indicates a potential hazard 

associated with the use of this equipment. It calls attention to a procedure, practice, condition, 
or the like, which if not correctly performed or adhered to, could result in death or serious injury.

WARNING:

 This symbol and/or the use of the word 

WARNING

 indicates a potential hazard 

from electrical shock. It calls attention to a procedure, practice, condition, or the like, which if 
not correctly performed or adhered to, could result in death or serious injury.

CAUTION:

 This symbol and/or the use of the word 

CAUTION

 indicates a potential hazard 

associated with the use of this equipment. It calls attention to a procedure, practice, condition, 
or the like, which if not correctly performed or adhered to, could result in minor or moderate 
injury.

IMPORTANT:

 The use of the word 

IMPORTANT

 in this manual calls attention to a procedure, 

practice, condition, or the like, which if not correctly performed or adhered to, could result in 
incorrect performance of or damage to the equipment and may void the warranty.

1.2.1 Analyzer Warnings

Refrigerant Blend Warning:

  The HVAC industry is continually introducing new refrigerants.  

Many of these new blends can be profi led using the Pur•Chek™.  

Sample Filter Warning:

  Replace the sample fi lter of the instrument AS SOON AS RED 

SPOTS OR DISCOLORATION BEGIN TO APPEAR ON THE OUTSIDE DIAMETER OF THE 
WHITE ELEMENT.  Failure to properly maintain and replace the sample fi lter will result in 
severe damage.

Sample Input Warning:

  The instrument requires connection of the supplied sample hose to 

the LOW SIDE OR VAPOR port of refrigerant storage cylinders or air conditioning systems.  
DO NOT attempt to introduce liquid or samples heavily laden with oil into the low side sampling 
hose.  DO NOT connect the sample hose to the HIGH SIDE or LIQUID port!

Damage caused to the instrument due to the use of the wrong hose on the wrong port will void 
the warranty.

Battery Charger Warning:

  When charging the optional battery with the 1000 mA charger, 

the charger will become warm.  If the charger becomes hot, unplug the charger immediately!  
When charging multiple battery packs, allow the charger to cool between each battery. 

 

 

 

 

 

 

 

Summary of Contents for PUR-CHEK

Page 1: ...Product Leadership Training Service Reliability Instruction 2100 9000 Operation and Maintenance Rev 0 June 2010...

Page 2: ...LIEU OF I ANY AND ALL OTHER WARRANTIES EXPRESS OR IMPLIED INCLUDING WITHOUT LIMITATION THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE AND II ANY OBLI GATION LIABILITY...

Page 3: ...r 5 3 4 Control Panel 6 3 5 Back Panel Connections 6 3 6 Hard Shell Storage Carrying Case 7 4 Operation 8 4 1 Battery Installation 8 4 2 Turning On the Unit 9 4 3 Calibration 9 4 4 Viewing the Test Re...

Page 4: ...Pur Chek Instruction 2100 9000 ii...

Page 5: ...or adhered to could result in minor or moderate injury IMPORTANT The use of the word IMPORTANT in this manual calls attention to a procedure practice condition or the like which if not correctly perf...

Page 6: ...or will not emit heavy loads of oil or liquid NEVER admit any sample into the instrument at pressures in excess of 500 psig 1 3 Features and Capabilities The Pur Chek HVAC Advanced Refrigerant Identif...

Page 7: ...levels of purity based on their recovery or use standards Sample gas is admitted into the instrument through the supplied sample hose and presented to the sensing device The instrument provides the u...

Page 8: ...unit The chart shown is for generic reference only Displays R410A Not suitable for R404A or R507A as they are presented as R134A Blend data shown below is for reference only at 70 F and should be veri...

Page 9: ...e will handle all of the refrigerant transfer and will provide containment up to 300psig The outer tube will provide protection of the inner tube from abrasion nicking cutting etc The hose is provided...

Page 10: ...e soft key label at the bottom of the graphic display Red and Green LED s at the top of the Control Panel are used for visual status indications Green LED Power On Off Soft Keys Red LED 3 5 Back Panel...

Page 11: ...ll Storage Carrying Case The hard shell storage carrying case is custom fit to the Pur Chek It provides rugged protection for the instrument as well as convenient storage for all components The enclos...

Page 12: ...nges per hour or locate the equipment DATE CODE WARNING TO REDUCE THE RISK OF FIRE DO NOT USE THIS EQUIPMENT IN THE VICINITY OF SPILLED LISTED 6P03 Design Pressure 300 psig Refrigerant Type R 12 R 134...

Page 13: ...internal pump This fresh air purges any excess refrigerant from the unit and ensures accurate test results Calibration requires that the hose be disconnected from the refrigerant cylinder or air condi...

Page 14: ...concentration is greater than 90 NON represents non condensable elements such as air or another dilut ing gas 4 5 Blend Refrigerants The Pur Chek includes the Blend Chek feature for determining the pr...

Page 15: ...Additional printouts may be made following the same procedure To exit the test press the EXIT button Figures 14 15 16 show sample printouts for various test results Bacharach Inc Refrigerant Identifi...

Page 16: ...he help screen Figure 17 TO SET THE ELEVATION PRESS ELEV BUNNON TO SET THE LCD CONTRAST PRESS CONT Figure 19 Figure 20 ELEV CONT DONE SET FEED DONE FEET METERS 400 122 5 2 Setting the LCD Contrast The...

Page 17: ...the new filter into the retaining clip Inspect the sample hoses for signs of oil entrapment Replacement of the sample filter usually requires cleaning or replacement of the sample hoses 5 4 Cleaning t...

Page 18: ...on the top of the printer press the STOP button Press the TEST button to print a test message and verify that the paper is installed properly Slide the paper through the slot in the printer door and c...

Page 19: ...re Rechargeable Battery 2100 9000 Instruction Manual 7 Service Centers Service and replacement parts can be found by contacting any of the following Bacharach Service Centers United States Bacharach I...

Page 20: ...Pur Chek Instruction 2100 9000 16 NOTES...

Page 21: ...Pur Chek Instruction 2100 9000 17 NOTES...

Page 22: ...ers 621 Hunt Valley Circle New Kensington PA 15068 PH 724 334 5000 Toll Free 800 736 4666 Fax 724 334 5001 Website www mybacharach com Email help mybacharach com Printed in USA Registered Trademark of...

Reviews: