Operation
4.11 Memory to PC Screen
(For ‘Advanced’ PCA Models 40, 45, 50, 55, 60 & 65)
MEMORY TO PC
«TRANSMIT DATA
CLEAR MEMORY
PCA
The Memory To PC Screen is displayed by repeatedly pressing the
MENU
key
from the Combustion Test Screen. Use this screen to either transmit
all
stored memory locations to a computer, or clear
all
memory locations.
TRANSMIT DATA
Before data can be transmitted to a personal computer, the PCA’s RS-232
output must first be connected to an unused computer COM port using
serial data cable Part No. 24-1073 (see Figure 4-4). Also, a communica-
tions program (i.e., ProcommPlus
®
, Windows 3.x Terminal, or Windows 9x
Hyper Terminal) must be installed, and its communications parameters
configured for:
9600 baud, 8 data bits, 1 stop bit, no parity, and no
handshaking.
!
"
"
#
"$
%
$
&
'
(
)*
Figure 4-4. Connecting the Serial Data Cable
4-14
Instruction 0024-9219