Bacharach OXOR II 19-7037 Instructions Manual Download Page 9

6

PARTS/SERVICE

6.1

Parts List

Item

Part No.

Battery Cover

19-3029

Basic Probe/Hose Assy.

19-3086

Optional Probe/hose Assy.

19-3076

6.2

Bacharach Sales/Service Centers

7

United States

Bacharach, Inc.

621 Hunt Valley Circle

New Kensington, PA 15068

Phone: 724-334-5051

Fax: 724-334-5723

E-mail: [email protected]

Canada

Bacharach of Canada, Inc.

250 Shields Court, Unit #3

Markham, Ontario L3R 9W7 Canada

Phone: 905-470-8985

Fax: 905-470-8963

E-mail: [email protected]

México

Bacharach de México

Playa Regatas No. 473 Tercer Piso

Col. Militar Marte

Delegación Iztacalco, 08830

México D.F. México

Phones: +52-555-634-7740

+52-555-634-7741

FAX:

+52-555-634-7738

E-Mail: [email protected]

Website: www.bacharach-mexico.com

Europe

Bacharach Instruments

Sovereign House, Queensway

Leamington Spa

Warwickshire CV31 3JR

United Kingdom

Phone: +44-1926-338111

Fax: +44-1926-338110

Email: [email protected]

Summary of Contents for OXOR II 19-7037

Page 1: ...n Analyzer Part No 19 7037 19 7044 Rev 6 October 1999 Bacharach Inc 621 Hunt Valley Circle New Kensington PA 15068 PH 724 334 5000 FAX 724 334 5001 Web www bacharach inc com E mail help bacharach inc...

Page 2: ...icalsensors arewarrantedforaperiod of six months THE FOREGOING WARRANTIES ARE EXCLUSIVE AND ARE GIVEN AND ACCEPTED IN LIEU OF I ANY AND ALL OTHER WARRANTIES EXPRESS OR IMPLIED INCLUDING WITHOUT LIMITA...

Page 3: ...ory or training assistance should be obtained before use Assistance is available by calling your nearest Bacharach Service Center 1 INTRODUCTION TheOxor IIisacommercial gradepor tableinstrumentdesigne...

Page 4: ...observ ingproperbatterypolarity installfour C size batteriesintotheinstrument sbatterycompart ment Recommended battery types Duracell Alkaline or equivalent After the batteries are installed replace t...

Page 5: ...trument s electronic circuitry The instrument will operate once batteries are properly installed and the PTC thermistor is allowed to cool 3 2 Probe Installation Install the probe by sliding the end o...

Page 6: ...abilizes Turn off the instrument by sliding the POWER switch to OFF 4 2 Adjusting the Instrument After being turned on and warmed up for at least 1 minute the instrument should indicate 20 9 in fresh...

Page 7: ...the metal clip at the bottom of the instrument s case you can hang the instrument by its strap on nearby objects such as nails sheet metal or valve handles 4 5 Using the Probe Thebasicprobe ortheoptio...

Page 8: ...eds to be calibrated at regular intervals to ascertain that it still meets its accuracy specification A regular calibration schedule should be established Detailed calibration maintenance procedures a...

Page 9: ...lds Court Unit 3 Markham Ontario L3R 9W7 Canada Phone 905 470 8985 Fax 905 470 8963 E mail bachcan idirect com M xico Bacharach de M xico Playa Regatas No 473 Tercer Piso Col Militar Marte Delegaci n...

Page 10: ...Notes 8...

Reviews: