2  TECHNICAL CHARACTERISTICS

CO Display Range ............... 0-1999 ppm CO
Accuracy .............................. ±10 ppm or ±5% of reading 
 

whichever is greater*

Response Time ..................... 90% of fi nal value within 40 sec.
Battery Requirements ........... 1.5 V, “C” cells, Qty. 4
Operating Time** ................ 14 to 16 hours, alkaline cells
Operating Temp. Range ....... 23 to 104°F (–5 to 40°C)
Relative Humidity ................ 10 to 85% non-condensing
Weight (w/o batteries) .......... 12 ozs. (341 grams)
Dimensions .......................... 8.6 x 3.5 x 2.9 in. (218 x 89 x 74 mm)

To prepare the instrument for operation, you 
must install four “C” size batteries, and (if 
desired) install the hose and probe as described 
in the following paragraphs.

For your convenience, and to ensure that the 
instrument will provide reliable CO indications, 
the CO sensor is installed and the instrument 
calibrated on 500 ppm of CO at the factory.

3.1  Battery Installation

Detach the elastic strap's metal clip at the bottom 
of the instrument, and slide off the battery cover 
as shown in Figure 2. Then while observing 
proper battery polarity, install four “C” size 
batteries into the instrument’s battery compart-
ment. (Recommended battery types: Duracell 
Alkaline or equivalent). After the batteries 
are installed, replace the battery cover and the 
elastic-strap clip.

*  Tighter accuracy in the lower ranges, up to ±2 ppm, may be attained if 

lower range calibration gases (eg. 100 ppm) are utilized.

** Times are with the backlight turned off. Continuous use of the backlight 

will decrease battery life.

3  PREPARING THE MONOXOR II

FOR OPERATION

Summary of Contents for Monoxor II

Page 1: ... CO Analyzer Part No 0019 7034 0019 7039 Rev 8 May 2010 Bacharach Inc 621 Hunt Valley Circle New Kensington PA 15068 PH 1 800 736 4666 FAX 724 334 5001 Web www mybacharach com E mail help mybacharach com Printed in U S A Registered Trademarks ...

Page 2: ...ctive in title All expendable items such as electrochemical sensors are warranted for a period of six months THE FOREGOING WARRANTIES ARE EXCLUSIVE AND ARE GIVEN AND ACCEPTED IN LIEU OF I ANY AND ALL OTHER WARRANTIES EXPRESS OR IMPLIED INCLUDING WITHOUT LIMITATION THE IMPLIED WARRAN TIES OF MERCHANTABILITYAND FITNESS FORAPARTICULAR PURPOSE AND II ANY OBLIGATION LIABILITY RIGHT CLAIM OR REMEDY IN C...

Page 3: ...ned before use Assistance is available by calling your nearest Bacharach Service Center Figure 1 Monoxor II 1 INTRODUCTION The Monoxor II is a commercial grade portable instrument designed to display concentrations of carbon monoxide CO gas between 0 and 2000 ppm This instru ment shows the presence of CO in a gas samplebydrawingthesampleintoitssen sorchamberbyabuilt inmotorizedpump Part 0019 7034 ...

Page 4: ...onvenience and to ensure that the instrumentwillprovidereliableCOindications the CO sensor is installed and the instrument calibrated on 500 ppm of CO at the factory 3 1 BatteryInstallation Detachtheelasticstrap smetalclipatthebottom oftheinstrument andslideoffthebatterycover as shown in Figure2 Then while observing proper battery polarity install four C size batteries into the instrument s batter...

Page 5: ...robe by sliding the end of its tubing over the gas inlet port on the top right side of the instrument as shown in Figure3 The tubing may be difficult to slide over the gas inlet port of the unit for the first time This was done intentionally to allow for a snug fit If necessary use a little dish washing liquid diluted in water or heat the end of the tube with hot tap water to help it slide onto th...

Page 6: ...forextendedperiodsoftime remove the batteries and ensure that the POWER switch is OFF The OFF position places a short across the CO sensor thus keeping the sensor from being destabilized while not in use 4 2 ZeroingtheInstrument After being turned on and warmed up for at least 1 minute the instru ment should indicate 000 5 ppm in fresh air If the instrument needs to be zeroed proceed as follows 1 ...

Page 7: ...such as nails sheet metal or valve handles 4 5 UsingtheProbe A rigid stainless steel probe with handle is used to draw a gas sample from the room grilles diffusers and furnace flues through a line dryer and flexible hose into the instrument A flexible probe option see Section 6 is available to give easy access to hot water heater flues and inside furnace heat exchangers The probe tube is detachabl...

Page 8: ...ilized while not in use 5 MAINTENANCE The Monoxor II needs to be calibrated at regular intervals to be cer tain that it still meets its accuracy specification A regular calibration schedule should be established between you and your nearest Bacha rach Service Center unless your facility has the necessary calibration equipment and personnel trained in the maintenance of gas detection equipment Deta...

Page 9: ...4 Line Dryer Filter Packing 0011 0122 6 2 BacharachSales ServiceCenters 7 United States Bacharach Inc 621 Hunt Valley Circle New Kensington PA 15068 Phone 724 334 5051 Fax 724 334 5723 Email help mybacharach com Canada Bacharach of Canada Inc 20 Amber St Unit 7 Markham Ontario L3R SP4 Canada Phone 905 470 8985 Fax 905 470 8963 Email bachcan idirect com ...

Page 10: ... nausea after 2 3 hours 400 ppm 0 04 Frontal headaches within 1 2 hours life threatening after 3 hours 800 ppm 0 08 Dizziness nausea and convulsions within 45 minutes Unconsciousness within 2 hours Death within 2 3 hours 1 600 ppm 0 16 Headache dizziness and nausea within 20 minutes Death within 1 hour 3 200 ppm 0 32 Headache dizziness and nausea within 5 10 minutes Death within 30 minutes 6 400 p...

Reviews: