Summary of Contents for H-10PM

Page 1: ...e industry today It will detect refrigerants with a sensitivity to effectively pinpoint both small and large leaks quickly and efficiently We encourage your review of this manual to assure satisfac to...

Page 2: ...ensitivity to pinpoint both large and small leaks can be controlled by setting the three posi tion Leak Size switch Panel Operating Controls Before you use the unit the first time 1 Remove the sticky...

Page 3: ...ty for locating 0 5 ounce or greater R134a leaks per SAE Std J1627 moving probe test con ditions It must always be used to verify performance and calibration when using the Calibration Reference Bottl...

Page 4: ...attery LED If it glows red the battery needs charging or you may operate the unit from a 12VDC source or with optional AC Adapter of the correct voltage and current 4 Check for sufficient airflow by p...

Page 5: ...icks second con dition Briefly moving the probe away from the leak for 1 2 seconds per mits the unit to re establish sensitivity Returning to the leak site the unit will alarm again Continuing this pr...

Page 6: ...r Adjustment for optimum performance and calibration The Calibration Reference Bottle sen sor heater circuit controls the sensitiv ity of the unit A heat setting that is too high causes instability du...

Page 7: ...eir indication is meaningless during subsequent leak testing activity B Check for proper heat adjustment the first time the unit is turned on and repeat on a daily basis This assures the product is ca...

Page 8: ...frigerants only such as R134a you also must verify the system is leak free using the SMALL setting For CFC and HCFC systems such as R11 R12 R22 R123 the MEDIUM setting is sufficient to verify that the...

Page 9: ...e black rubber probe tip 2 Pick out the filter with a pin or tweezers A fine screen will remain in the tip of the probe 3 Insert the new filter in the probe tip Make sure that the filter is firmly sea...

Page 10: ...sensor to cool before touching it 4 Unplug and discard the sensor 5 Insert a new sensor and close the sensor cover 6 Turn the Heater Adjustment to its full counterclockwise position 7 Apply power to t...

Page 11: ...ment section or replace bottle 3015 0864 2Replace filter in probe tip 3015 0784 Check air pump operation 3Move probe to clean atmo sphere for several minutes while sensor purges itself 4Turn unit off...

Page 12: ...ort circuit in sensor 4Atmosphere contaminated with excessive refrigerant gas Solution 1Replace the filter 3015 0784 2Remove sensor and blow it out with clean air not over 10psi If unsuccess ful repla...

Page 13: ...3015 4162 100VAC Power Supply Adapter will charge or run unit 3015 0131 120VAC Power Supply Adapter will charge or run unit 3015 0143 220 230VAC Power Supply Adapter will charge or run unit 3015 0147...

Page 14: ...ee Please include your company name telephone number includ ing area code and a contact name Limited Warranty The purchaser is warranted that this leak detector will be free of defects in mate rial an...

Page 15: ...05 470 8963 E mail bachcan idirect com M xico Bacharach de M xico Playa Regatas No 473 Tercer Piso Col Militar Marte Delegaci n Iztacalco 08830 M xico D F M xico Phones 52 555 634 7740 52 555 634 7741...

Page 16: ...015 0925 Rev 2 6 2006 621 Hunt Valley Circle New Kensington PA 15068 Ph 724 334 5000 Fax 724 334 5001 Toll Free 1 800 736 4666 Website http www bacharach inc com E mail help bacharach inc com SAE J162...