background image

15

Repair Information

Should it become necessary to 
repair your H-10G, please contact an 
Authorized Service Center. Units should 
be carefully packed to prevent shipping 
damage and shipped prepaid.

Warranty

Send units under warranty and a copy 
of the purchase receipt to an Authorized 
Service Center for repairs.  Please 
include your company name, telephone 
number including area code, and a con-
tact name. 

Non-Warranty

Units that are no longer under warranty 
will be repaired to factory specifications 
for a nominal fee. Please include your 
company name, telephone number includ-
ing area code, and a contact name.

Limited Warranty

The purchaser is warranted that this leak 
detector will be free of defects in material 
and workmanship for 3 years from date of 
purchase. This warranty does not cover 
sensors, reference leaks, filters, airflow 
balls, lamps, or probe tips. Damages 
caused by the user will not be covered. If 
any defects are discovered during the war-
ranty period, an Authorized Service Center 
will repair or replace the unit at their option.

The foregoing limited warranty is exclusive 
and in lieu of all other warranties, whether 
written or implied, and no warranty of mer-
chantability or fitness for purpose will apply.

Summary of Contents for H-10G

Page 1: ...performance service leak detector available in the indus try today It will detect refriger ants with a sensitivity that will effectively pinpoint both small and large leaks quickly and efficiently We...

Page 2: ...scope of its specifications For details on appropriate use refer to the gen eral model description application and operation discussions in this manual Before risking equipment damage or personal inju...

Page 3: ...nse to an industry that is in the process of converting to more environmentally safe refrigerants worldwide Ozone depleting chlorine is being reduced or eliminated in most refrigerants To adequately l...

Page 4: ...he H 10G for the first time remove the paper disc from the cap on the calibrate reference bottle fig 1 and allow a few minutes for the leak rate to stabilize This disc is used to avoid evaporation and...

Page 5: ...e that the actual height and final resting position of the red ball are not important See Figure 2 If the airflow ball does not rise Tap the probe lightly to ensure the ball is not sticking Check the...

Page 6: ...calibrate reference bottle for 2 3 seconds This allows enough time for the H 10G to pump down the concentration of gas which normally collects around the bottle s outlet and thus arrive at a steady st...

Page 7: ...rine based refrigerants Please refer to the Product Sensitivity Levels chart on the pocket of the inside lid or see this manual s Specifications section The term R12 sensitivity is used to represent c...

Page 8: ...nsor Life Extension The H 10G provides a sensor adjust ment that substantially extends sensor life This procedure also provides for a more accurately calibrated sensitivity throughout the sensor life...

Page 9: ...ery little maintenance A kit that contains the necessary expendable replacement parts is supplied with each unit Instructions for replacing these items are described in the following sec tions Replaci...

Page 10: ...the cover 5 Set the sensor heat control fig 4 to its 7 o clock position 6 Place the unit in operation and check its sensitivity by following the procedure in steps 5 6 and 7 in the Operating Instruct...

Page 11: ...arger leak size Problem Excessive response to cali brate reference Cause High line voltage Solution Reset sensor heat control more counterclockwise Problem Audio normal but probe lamp does not flash C...

Page 12: ...sor exposed to excessive amounts of halogen 4Water in probe 5Low line voltage Solution 1Replace with part 3015 0864 2Replace filter in probe tip Check operation of pump 3Place probe to clean air and a...

Page 13: ...e no movement Switch Position LG MD SM R134a 5 0 0 5 0 1 R12 3 0 0 1 05 Power Supply 10 100 120 220 240 volts 50 60 Hz 20 watts in accor dance with rating plate Response Time Approx 1 second Reference...

Page 14: ...3015 0641 Clear Probe Tip 3015 0680 Rubber Probe Tip 3015 0486 Replacement Sensor 3015 0737 Maintenance Kit 12 Filters 4 Airflow Balls 3015 0781 Tune Up Kit Sensor 100 Filters 4 Airflow Balls 3 Rubber...

Page 15: ...al fee Please include your company name telephone number includ ing area code and a contact name Limited Warranty The purchaser is warranted that this leak detector will be free of defects in material...

Page 16: ...ce Center 621 Hunt Valley Circle New Kensington PA 15068 Phone 724 334 5051 Fax 724 334 5723 E mail help MyBacharach com Canada Bacharach of Canada Inc 20 Amber St Unit 7 Markham Ontario L3R 5P4 Canad...

Page 17: ...17 Notes...

Page 18: ...18 Notes...

Page 19: ...19 Notes...

Page 20: ...3015 0846 REV 8 9 2012 621 Hunt Valley Circle New Kensington PA 15068 Ph 724 334 5000 Fax 724 334 5001 Toll Free 1 800 736 4666 Website http www MyBacharach com E mail help MyBacharach com...

Reviews: