Single Gas Instrument Service Manual

Page 18 

Bacharach, Inc.

 Instruction 

0019-9166

 

5.2  Instrument Assembly (Figs 5-2 & 5-3)

Figure 5-2.

 

Replacement 

Parts, 

Chamber Assem-

bly 

Exploded View

Item Description 

 

Part 

No.

  1 

Adapter, Motor Shaft 0024-0412

  2 

Battery Clip, push on 0004-3113

  3 

Battery Cover with Foam Pad 

0019-3029

 4 

Chamber 

 

0019-3090

  5 

Front Cover w/Display Window (Dioxor II) 

0019-3079

 

 

Front Cover w/Display Window (Monoxor II) 

0019-3055

 

 

Front Cover w/Display Window (Nonoxor II) 

0019-3078

 

 

Front Cover (Monoxor II H) (order with 0019-0437)  0019-3014

 

 

Display Window (Monoxor II H) (order with 0019-3014) 0019-0437

 6 

(Not 

Used)

 7 

Fan-Blade 

Assembly 

 

0019-3013

 8 

LCD 

 

0004-3700

 9 

Motor 

Assembly 

 

0019-3063

  10 

Nut, Hex M2 x .4 

 

0502-0007

  11 

O-Ring and Membrane 

0024-0520

  12 

Printed Circuit Board Assy. (Dioxor II) 

0019-3022

 

 

Printed Circuit Board Assy. (Monoxor II) 

0019-3012

 

 

Printed Circuit Board Assy. (Nonoxor II) 

0019-3020

 

 

Printed Circuit Board Assy. (Monoxor II H) 

0019-3094

 13 

PTC Resistor 

 

0204-9427

  14 

Rear Case w/ Label (Dioxor II) 

0019-3082

 

 

Rear Case w/ Label (Monoxor II) 

0019-3053

 

 

Rear Case w/ Label (Nonoxor II) 

0019-3081

 

 

Rear Case (Monoxor II H) (order with 51-2347) 

0019-3008

 

 

    Label (Monoxor II H) (order with 0019-3008) 

0051-2347

 15 

Retaining Ring 

 

0002-2675

  16 

Screw, Cheese head, M2 x .4 x 30 mm 

0501-3807

  17 

Screw, Phillips head, M2 x .4 x 6 mm 

0501-3803

  18 

Screw, Phillips head, M3 x .5 x 8 mm 

0501-3806

 19 

Sensor, SO

2

 (Dioxor II) 

0019-8002

 

 

Sensor, CO (Monoxor II) 

0024-0498

   Sensor, 

,NO

X

 (Nonoxor II) 

0019-8001

 

 

Sensor, CO (Monoxor II H) 

0019-8016

  20 

Set Screw, #4-40 x 1/8 LG 

0002-0001

 21 

Strap 

 

0019-3028

 22 

Strap Clip 

 

0019-3030

 23 

Strap Retainer 

 

0019-3027

 24 

Switch Cover 

 

0019-3021

Summary of Contents for DIOXOR II

Page 1: ...ERVICE MANUAL for DIOXOR II MONOXOR II MONOXOR II H High Range NONOXOR II Rev 7 May 2010 Bacharach Inc 621 Hunt Valley Circle New Kensington PA 15068 Phone 1 800 736 4666 Fax 724 334 5001 Web www myba...

Page 2: ...Bacharach Dioxor Monoxor and Nonoxor are registered trademarks of Bacharach Inc Copyright Bacharach 1997 2010 all rights reserved A...

Page 3: ...it Board Replacement 10 2 6 ChamberAssembly Servicing 11 3 0 SENSOR CALIBRATION 12 3 1 Monoxer II CO Calibration 12 3 2 Dioxor II SO2 Monoxor II H CO and Nonoxor II NOx Calibration 13 4 0 TROUBLESHOOT...

Page 4: ...he same in this instruction Instrument maintenance which includes information on how to Open and close the case Clean the Fan Assembly and chamber assembly area Replace the sensor Replace the Printed...

Page 5: ...c strap over top of the instrument Fig 2 1 2 Slide off battery cover 3 Remove batteries 4 Using a No 1 Phillips head screwdriver remove the two screws from the rear of the case 5 Lift up the bottom po...

Page 6: ...r the chamber assembly is in place 1 Ensure that the P C B is properly positioned face down over its locating tab on the front case Fig 2 2 2 Properly position the chamber assembly between the ribs of...

Page 7: ...ing the two screws and nuts that secure the Chamber to the Motor Assembly Fig 2 3 NOTE Do not remove the Fan Assembly unless it s absolutely neces sary for cleaning or repair purposes 4 If it is neces...

Page 8: ...ng fully Tighten the set screw to approxi mately 32 40 ounce inches using the 05 in Allen wrench Spin the Fan Assembly to be sure it will run in the chamber b Mate and secure the Chamber and Motor Ass...

Page 9: ...hat secure the Sensor to the chamber assembly then remove the Sensor along with its O ring and Membrane from the chamber assembly 4 Remove and discard of the old Sensor in accordance with local and fe...

Page 10: ...ensor connector from the P C B NOTE For SO2 CO Sensors only If the Sensor is not going to be immediately plugged into the new P C B place a shorting wire between sensor terminals R and S 4 Remove the...

Page 11: ...he Sensor along with its O ring and Membrane from the chamber assembly 3 Using a No 1 Phillips head screwdriver disassemble the Chamber from the Motor Assembly Fig 2 3 4 To remove the Fan Assembly ref...

Page 12: ...edure WARNING Perform this procedure in a well ventilated area CO is toxic 1 Assemble the calibration equipment by connecting the Carbon Monoxide Gas Cylinder and the components of the Calibration Kit...

Page 13: ...nel POWER switch to OFF 8 Disassemble the calibration equipment setup and store the components in the calibration kit s carrying case The presence of SO2 and NOX gas in small amounts and CO gas in lar...

Page 14: ...te be fore switching on unit to allow its PTC resistor to cool Replace P C B Refer to Section 2 5 Printed Circuit Board Replacement Replace P C B Refer to Section 2 5 Printed Circuit Board Replacement...

Page 15: ...defective P C B defective Replace batteries with four fresh C Alkaline cells Break in a new Motor for at 30 minutes Replace Motor Assembly Refer to Section 2 6 Chamber Assembly Servicing Check Sensor...

Page 16: ...ns See Fig 2 2 Run Motor for at least 3 hours to wear away arc spots If display still bounces replace Motor Assembly Refer to Sec tion 2 6 Chamber Assembly Servicing Tighten screws Refer to Sec tion 2...

Page 17: ...not shown 0019 3104 2 Probe Tube 0019 3073 3 Probe Handle 0019 3017 4 Screw Phillips head M3 x 5 x 8 mm 0501 3806 5 Tubing 5 16 OD X 3 16 ID 0003 6109 6 Filter Saturator Bushing 0011 0074 7 Filter Pac...

Page 18: ...1 O Ring and Membrane 0024 0520 12 Printed Circuit Board Assy Dioxor II 0019 3022 Printed Circuit Board Assy Monoxor II 0019 3012 Printed Circuit Board Assy Nonoxor II 0019 3020 Printed Circuit Board...

Page 19: ...Single Gas Instrument Service Manual Instruction 0019 9166 Bacharach Inc Page 19 Figure 5 3 Replacement Parts Back and Front Exploded Views...

Page 20: ...Monoxor II H 0019 9180 Calibration Card 0019 9150 Service Manual This Manual 0019 9166 Label Carrying Case 0019 3077 Probe Stop for Securing Probe in a Flue or Stack 0024 0434 Warranty Card 0006 8825...

Reviews: