Baby Brezza Formula Pro FRP0045 Instructions For Set-Up, Use And Cleaning Download Page 8

NOTES:

14

13

Machine has not been cleaned regularly.

Make sure silicone scraper is installed correctly.

Not enough powder
dispensed.

Condition

Possible Cause

Possible Remedy

Refill Powder Container with more powder. 

Powder level in powder container is too low. 

Silicone scraper is not correctly installed. 

Measuring wheel is set to incorrect number 
for powder type.

Make sure the measuring wheel is set to the correct 
number for your powder type. See page 5, Steps 1-2a. 

Too much powder 
dispensed

Measuring wheel is set to incorrect
number for powder type.

Make sure the measuring wheel is set to the correct 
number for your powder type.  See page 5, Steps 1-2a.

Locking cover is not under tab in
powder container.

Check locking cover and make sure the front edge is 
locked under the tab in the powder container. 
See page 6, Step 5 for details.

Not dispensing water

Water Tank not fully seated.

Push Water Tank down all the way on Base.

Powder Container Parts stuck

Not dispensing water or formula. 
Yellow and Green Temp LEDs flash 
when start is pressed.

Water Tank not fully seated. 

Push Water Tank down all the way on Base.

Clean heater plate and use mineral free water if 
possible. 

Scaling on water tank heater plate.

Mineral rich water used persistently. 

Powder build-up on funnel  cover and 
underside of powder container.

Clean funnel cover and powder container bottom 
frequently after every 4 bottles.

Frequent use without cleaning underside
of powder container.  See page 9, Step 3 for 
details.

Turn off power, remove powder from Powder 
Container, check for and clear any obstructions, 
turn power back on and resume normal use.

Water Tank is full, red no 
water light           is on. 

TROUBLESHOOTING

 

Disassemble, clean by hand-washing, completely
dry all parts and reassemble.

If you can not remedy problems with the machine by using the troubleshooting chart above,

please contact Customer Service at: [email protected]

Summary of Contents for Formula Pro FRP0045

Page 1: ...nty is not available to retailers or other commercial purchasers or owners We warrant that your Baby Brezza Formula Pro will be free of defects in material or workmanship under normal home use for two years from the date of original purchase Customer will be required to present original proof of purchase in order to obtain the warranty benefits In the event that you do not have proof of purchase d...

Page 2: ... We ll show you how in the following pages To get the most out of your new Formula Pro read these instructions and retain them for future reference Save these instructions 1 WARNING For infants less than 6 months old always use boiled water that s then been cooled to room temperature Never pour boiling hot water in water tank Or use bottled purified water suitable for infant formula preparation Ta...

Page 3: ...e machine will not operate while the green yellow lights flash The heater in the water tank will warm the water and keep it warm as long as the machine is powered on If you refill the water tank with room temperature water and need to use the machine right away the machine can be used while water is heating flashing yellow light Place 300ml or larger container to catch water Your Formula Pro is no...

Page 4: ...leaning videos at babybrezza com video 2 Place stirring wheel in powder container align with axle and push down so it touches the locking cover 1 Place the front edge of locking cover UNDERTHETAB in the powder container 2 Slide hole over axle and press down Fit the powder container lid on the powder container with the tab towards the back left and turn clockwise to lock into place The powder conta...

Page 5: ...ver overfill or pack powder in container Wipe any powder spilled on machine with a clean damp cloth 1 3 4 When dispensing is complete make sure to check level of mixed formula Level will appear higher due to added powder volume and or variance in bottle markings Check for clumps and shake or stir the bottle if necessary Check temperature and Feed baby Press the start button to begin dispensing 8 P...

Page 6: ...It is very important to keep the entire Formula Pro clean 1 1 10 1 2 3 2 Please watch set up and cleaning videos at babybrezza com video DAILY CLEANING To wash always use a non abrasive sponge and hand wash with warm soapy water Never use hot boiling water or put any parts in a dishwasher or sterilizer Dry parts thoroughly always make sure parts are completely dry before using again Must be cleane...

Page 7: ...use Machine will not start Unit is unplugged Unit is not turned on Funnel is removed or not fully inserted Water Tank is removed or not fully seated Water level is below MIN line Dump out and refill with room temperature water 11 TOUCH DISPLAY CONTROLS TEMPERATURE INDICATOR LIGHTS Flashing Yellow means water is heating Solid Green means water is warm ready Flashing Yellow Green means water poured ...

Page 8: ...ter Water Tank not fully seated Push Water Tank down all the way on Base Powder Container Parts stuck Not dispensing water or formula Yellow and Green Temp LEDs flash when start is pressed Water Tank not fully seated Push Water Tank down all the way on Base Clean heater plate and use mineral free water if possible Scaling on water tank heater plate Mineral rich water used persistently Powder build...