Installation & Ope Maintenance 

AcousticMAX Smoke Vent 

Model(s): BSVZ/BSVY

 

2

 

 

 

Great Products. Better Partners. 

Babcock-Davis is a leader in roof hatches, smoke vents and safety railings for the commercial roofing market. We also manufacture architectural 
access and safety-related building products for commercial structures. Babcock-Davis provides local connections through a broad distribution 
network to accelerate and simplify the building process for contractors and building owners, offering hassle-free services including access to 
technical experts, REVIT tools for BIM, HPDs for LEED v4, 3-part specifications and AIA-accredited continuing education courses. 
 

Introd Safety 

Please read the complete instructions carefully before beginning any work. To ensure proper 
installation and performance of the product, the following actions must be completed by the 
installing contractor. Failure to do so will affect product warranty. 

Transpor Storage 

o

 

Inspect all shipments and materials for missing or damaged components and hardware. 

o

 

Material must be stored in a clean, dry location. 

Preparation 

 

Locate the packing slip(s) and/or shop drawings. 

 

Verify that all products listed on the packing slip are included in the package. 

 

Check the products for damage. If products are damaged, report a freight claim 
immediately and leave the products in their packaging. If you sign for products without 
reporting damage you waive your right to a freight claim and will be responsible for their 
replacement cost. 

 

Read the instructions thoroughly before beginning installation. 

 
 

INSTALLATION 

 
The following is a general instruction for installing, operating and maintaining smoke vent 
products. These are recommended general guidelines only. Locally accepted roofing and 
sealing practices and procedures should be followed as appropriate for the different roofing 
systems. This product may be installed on a flat or sloping roof. When installed on a slope up 
to 7:12 pitch 

(30˚), 

the hinge side must run parallel with the  slope. 

CAUTION:  Smoke Vent 

Doors Are Under Spring Pressure. 
 

1.

 

Ensure that the roof mounting surface is level to avoid twisting of the smoke vent base. 
It is essential that the vents are installed level and square for the door to make a proper 
seal. Place the smoke vent over the existing opening in the roof that has been prepared 
with appropriate roofing membrane, if applicable.

 

a.

 

The roof rough opening dimensions are equal to the vent dimensions as 

measured from the inside curb to inside curb. For example, a 48” x 96” smoke 
vent will have a rough opening of 48” by 96”.

 

GENERAL SAFETY PRECAUTIONS 

Improper selection, installation, or use can cause personal injury or property damage. 

It is solely the responsibility of the user, through their own analysis, to select products suitable to the specific application 
requirements, ensure proper maintenance and use as intended. Follow local, state, and federal regulations for proper 
installation and operation requirements.

 

 

Summary of Contents for ACOUSTIMAX BSVZ

Page 1: ...ants and for effective fire fighting conditions within a building The smoke vent is not intended for use as general purpose building ventilation devices International Building Code IBC requires smoke...

Page 2: ...at all products listed on the packing slip are included in the package Check the products for damage If products are damaged report a freight claim immediately and leave the products in their packagin...

Page 3: ...by others Bolt or otherwise fasten roof hatch curb flange to roof deck using 3 8 or 1 2 bolts with washers b Mark the predrilled 3 16 diameter holes from the mounting flange through to the roof deck t...

Page 4: ...owners offering hassle free services including access to technical experts REVIT tools for BIM HPDs for LEED v4 3 part specifications and AIA accredited continuing education courses 1 Smoke vents are...

Page 5: ...at the smoke level using a hand held propane tank torch Make sure to have replaceable fusible links on hand to reset the latch and close the doors An alternative method is to remove the fusible link t...

Page 6: ...ess to technical experts REVIT tools for BIM HPDs for LEED v4 3 part specifications and AIA accredited continuing education courses If there are any questions during the installation operation or main...

Page 7: ...ontractors and building owners offering hassle free services including access to technical experts REVIT tools for BIM HPDs for LEED v4 3 part specifications and AIA accredited continuing education co...

Page 8: ...side of the unit 4 Attach and wind the 1 8 cable taught onto the floor level winch See Figure A 5 Open the smoke vent by pulling the interior manual release now rigged to a location near the floor wi...

Page 9: ...sh button controller The system is comprised of linear actuators one per cover a control box mounted to the inside of the smoke vent curb a 2 position open close push button station These smoke vents...

Page 10: ...ser releases the open button or the open position internal limit switch for actuator closes Works individually for each actuator User presses and holds the close button Controller checks to ensure the...

Reviews: