babcockdavis ACOUSTIMAX BSVZ Installation, Operation And Maintenance Manual Download Page 1

©2023 Babcock-Davis, Inc. 

Rev 02/2023

 

 

Direct Service Done Right 

Since 1948, Nystrom has been the go-to manufacturer of specialty building products providing a wide range of floor, roof, wall, 
ceiling, and stair access products that create safer, more accessible buildings. We offer hassle-free services including access

 

to 

technical experts, REVIT tools for BIM, HPDs for LEED v4, 3-part specifications and AIA-accredited continuing education courses. 

Installation, Operation 

 

+ Maintenance Manual

 

 

1

 

 

Great Products. Better Partners. 

Babcock-Davis is a leader in roof hatches, smoke vents and safety railings for the commercial roofing market. We also manufacture architectural 
access and safety-related building products for commercial structures. Babcock-Davis provides local connections through a broad distribution 
network to accelerate and simplify the building process for contractors and building owners, offering hassle-free services including access to 
technical experts, REVIT tools for BIM, HPDs for LEED v4, 3-part specifications and AIA-accredited continuing education courses. 
 

ACOUSTIMAX™ SMOKE VENT

 

Model(s): BSVZ/BSVY 

 

GENERAL DESCRIPTION 

Acoustical smoke vents are designed to open 
automatically to provide emergency smoke and heat 
ventilation. Prompt venting during fire emergencies is 
essential for the safe evacuation of occupants and for 
effective fire-fighting conditions within a building. The 
smoke vent is not intended  for use as general-purpose 
building ventilation devices.  International  Building 
Code (IBC) requires smoke venting in a variety of 
applications including Section 410 for stages and 
platforms, Section 910 for factory and storage 
occupancies

 

Acoustical smoke vents are primarily used in theaters and performing arts centers because 
they block the intrusion of exterior environmental noise.  Acoustical smoke vents provide both 
sound control and thermal performance. The SVZ has STC50/OITC 47 and ISO 140-18 Rainfall 
36.7 dB sound ratings. The SVY has STC50/OITC 39 sound ratings. 

The AcousticMAX sound rated series meets International Building Code IBC 1207 sound 
transmission class requirements and is used in high end theater applications as well as in 
building applications where condensation is a concern. 

Sound transmission is tested by an independent lab accredited by the U.S. Department of 
Commerce and the National Institute of Standards and Technology for conducting official 
acoustical test procedures for  sound transmission class (STC), Outdoor-Indoor Transmission 
Class (OITC), and Sound Insulation of Building Elements (rainfall dB) according to the following 
tests: 

 

ASTM E90 Laboratory Measurement of Airborne Sound Transmission of Building 
Partitions 

 

ASTM E1332 Standard Classification for Determination of Outdoor-Indoor Transmission 
Class 

 

ISO 140 Acoustics Laboratory Measurement of Sound Insulation of Building Elements 

 

Summary of Contents for ACOUSTIMAX BSVZ

Page 1: ...ants and for effective fire fighting conditions within a building The smoke vent is not intended for use as general purpose building ventilation devices International Building Code IBC requires smoke...

Page 2: ...at all products listed on the packing slip are included in the package Check the products for damage If products are damaged report a freight claim immediately and leave the products in their packagin...

Page 3: ...by others Bolt or otherwise fasten roof hatch curb flange to roof deck using 3 8 or 1 2 bolts with washers b Mark the predrilled 3 16 diameter holes from the mounting flange through to the roof deck t...

Page 4: ...owners offering hassle free services including access to technical experts REVIT tools for BIM HPDs for LEED v4 3 part specifications and AIA accredited continuing education courses 1 Smoke vents are...

Page 5: ...at the smoke level using a hand held propane tank torch Make sure to have replaceable fusible links on hand to reset the latch and close the doors An alternative method is to remove the fusible link t...

Page 6: ...ess to technical experts REVIT tools for BIM HPDs for LEED v4 3 part specifications and AIA accredited continuing education courses If there are any questions during the installation operation or main...

Page 7: ...ontractors and building owners offering hassle free services including access to technical experts REVIT tools for BIM HPDs for LEED v4 3 part specifications and AIA accredited continuing education co...

Page 8: ...side of the unit 4 Attach and wind the 1 8 cable taught onto the floor level winch See Figure A 5 Open the smoke vent by pulling the interior manual release now rigged to a location near the floor wi...

Page 9: ...sh button controller The system is comprised of linear actuators one per cover a control box mounted to the inside of the smoke vent curb a 2 position open close push button station These smoke vents...

Page 10: ...ser releases the open button or the open position internal limit switch for actuator closes Works individually for each actuator User presses and holds the close button Controller checks to ensure the...

Reviews: