PLEASE CONTACT THE FACTORY OR YOUR DISTRIBUTOR IF YOU HAVE ANY QUESTIONS OR 

 

NEED ASSISTANCE. 
 

 

Customer Service:

 1-800-835-8012 or 713-467-4438 (8:00 a.m. to 5:00 p.m. CST US) 

 

6. WARRANTY 

 

All components of the LS7000 are warranted to be free from defects in material and workmanship for a 
period of two years from the date of purchase. This warranty applies to general purchaser and to 
components installed, serviced and operated according to instructions. 
 
Babbitt International, Inc. will repair or replace, at its option, FOB at its plant or any other location 
designated, any part which proves to be defective in manufacture or workmanship. 
 
All claims must be made in writing within the warranty period. No claims outside of the warranty period 
will be honored. 
 
Warranties are not applied to any components which have been damaged by improper installation, use, 
exposure to unusual atmospheric conditions or components which have been misused, abused, damaged 
by neglect or accident. This warranty shall not apply to any components which have been altered or 
repaired without the prior written consent of Babbitt International, Inc. 
 
Babbitt International, Inc. assumes no responsibility or liability for any labor or material back charges, 
without written authorization. Any products returned must be with prior written authorization. 
 
THE FOREGOING IS IN LIEU OF ALL OTHER WARRANTIES, EXPRESSED OR IMPLIED, 
INCLUDING ANY WARRANTIES OF MERCHANTABILITY AND/OR FOR FITNESS 
FORPARTICULAR PURPOSE, AND BABBITT INTERNATIONAL, INC. ASSUMES NO 
OTHERLIABILITIES EXPRESSED OR IMPLIED. BABBITT INTERNATIONAL, INC. SHALL NOT 
BELIABLE FOR NORMAL WEAR AND TEAR, NOR FOR DIRECT, INCIDENTIAL 
ORCONSEQUENTIAL DAMAGES. IN NO EVENT SHALL BABBITT INTERNATIONAL 
INCORPORATED’S LIABILITY EXCEED THE PRICE OF ITS PRODUCT AT THE TIME OF 
PURCHASE 

Summary of Contents for LS7000

Page 1: ...LS7000 LEVEL SWITCH OWNERS MANUAL INSTALLATION CALIBRATION TROUBLESHOOTING WARRANTY P O Box 70094 Houston TX 77270 713 467 4438...

Page 2: ...r problems arise during installation please contact Customer Service 1 800 835 8012 or 713 467 4438 8 00 a m to 5 00 p m CST US Failure to follow safe installation and servicing guidelines could resul...

Page 3: ...tion 5 1 4 GA Drawing 5 3 INSTALLATION 6 3 1 Inspection 6 3 2 Bench Test 6 3 3 Physical Installation 6 3 4 Removing the Electronics 7 3 5 Typical Applications and Wiring Diagrams 8 4 CALIBRATION 14 4...

Page 4: ...rical Power 115 VAC 15 50 60 Hz 2 watts standard 12 VDC 24 VDC or 230 VAC optional Output 2 Form C contacts DPDT relay 5 amp resistive At 125 250 VAC 30 VDC Fuse On board 250 mA 125 volts Fail Safe Se...

Page 5: ...www babbittinternational com Reference Manual 2021 5 1 3 Ordering Information 1 4 GA Drawing...

Page 6: ...2 On the bench hook up the appropriate power to L1 and L2 The operating voltage of the LS7000 is marked on the power supply board Hold the unit so that nothing is touching any surface and press the t...

Page 7: ...dry materials mount the LS7000 in the top of the vessel whenever possible This allows you to lengthen the probe if necessary b Avoid mounting the LS7000 near the product inlet vent return lines dust c...

Page 8: ...ONTACTS SUPPLY VOLTAGE NOTE EACH LS7000 POWER SUPPLY IS INTENDED FOR ONLY ONE SUPPLY VOLTAGE THIS VOLTAGE IS PRINTED ON THE POWER SUPPLY BOARD FOR 115 VAC OR 230 VAC UNITS HOOK UP THE HOT LEAD TO L1 A...

Page 9: ...www babbittinternational com Reference Manual 2021 9...

Page 10: ...www babbittinternational com Reference Manual 2021 10...

Page 11: ...www babbittinternational com Reference Manual 2021 11...

Page 12: ...www babbittinternational com Reference Manual 2021 12...

Page 13: ...www babbittinternational com Reference Manual 2021 13...

Page 14: ...E S3 and S4 also select fail safe high level FSH or fail safe low level FSL 2 Select the timing range using S1 and S2 as shown on the chart below next page 3 Adjust the time adjustment potentiometer c...

Page 15: ...djustment potentiometer clockwise CW until it comes on 3 Turn the sensitivity adjustment pot counter clockwise CCW until the Red LED just goes out This sets the unit to its maximum sensitivity If in y...

Page 16: ...go out If it does repair replace or clean antenna probe If LED does not go out replace electronics Bad sensing card Repair or replace card Unit triggers when material Improper mount of probe Contact...

Page 17: ...applied to any components which have been damaged by improper installation use exposure to unusual atmospheric conditions or components which have been misused abused damaged by neglect or accident Th...

Reviews: