6
Manual: FCCT - Filter Changer Camera Tilter
Preparing the FCCT for Installation
1. Remove the dark-slider. You'll notice that
it is held in place by three neodymium
magnets, which ensure filters can be
easily removed and precisely returned to
the same position.
2. Remove the FCCT-RASA-flange
4
by
loosening the six screws
1
(see page
5) with the 1.3 mm Allen key. You don't
have to remove them, loosening them is
enough
3. Now turn the FCCT on the other side
and loosen the three pairs of adjustment
screws of the tilter
2
with the extra-
long 2 mm Allen key. You don't have to
remove them, it is enough if they stand
out a little bit.
2
The pictures show the FCCT I. The procedure is the same for the FCCT II, only the
FCCT-RASA-flange and the FCCT-QHY-flange look different.