Controller Connectors

 

The controller is a device responsible for the process of displaying the content by the light 
signalling device.  

 

det. A, det. B, det. C

  – LED module connectors; 

det. D

 –  RS-485/RS-422 connector; 

det. E

 – 0/20mA digital current loop; 

det. F

 – RS-232 connector; 

det. G

 – Ethernet connector; 

det. H

 – 

DEF

 microbutton; 

det. I

 – housing earthing soldering 

point; 

det. J

 – network power supply connector 

Fig. 7

 

LED Module Connectors

 

 

det. A, 

– operator panel connector (dry contact)

 

Fig. 8 

Summary of Contents for TL-280

Page 1: ...Page 1 TL 280 STOP GO LIGHT OPERATION SETUP GUIDE V1 1 ...

Page 2: ...Module Connectors 9 Communication Connections 10 1 RS 232 connector 11 2 RS 485 RS 422 connector 11 3 0 20mA digital current loop 11 4 Operator panel dry contact 11 5 Ethernet 11 Automatic brightness control of the light signalling device 12 Initial start up 12 Changing Ethernet Settings 12 Additional options 13 Disposal and recycling 13 Packaging material recycling 13 Device disposal 13 Most comm...

Page 3: ...ector Power Cable 2 Meter 120 VAC US Plug Weight 1 5kg 3 3lbs Transport and Storage The device is sensitive to mechanical damages Care should be taken to properly protect the device during transport to eliminate any damage It is forbidden to transport the device components separately in a collective package each component must be packed separately and cannot bump during transportation Due to prote...

Page 4: ...e 4 Fig 1 TL 280 Dimensions Fig 2 Mounting The roof functions as a mounting bracket Fig 3 Fig 3 NOTICE It is forbidden to make any additional mounting points or any holes in the device assembly components ...

Page 5: ...he roof construction allows you to mount the signalling device on posts with diameters of 50 70mm 2 2 8in and 100 120mm 3 9 4 7in using a U bolt with a rod diameter of 8mm 0 7in Fig 4 or on the BT 470 scale display visor Fig 5 Fig 4 Fig 5 ...

Page 6: ... the set protocol reset to the default settings The DEF microbutton used to operate the menu is located inside the signalling device However after unscrewing the lock screw it is accessible through the technological hole without opening the device det A lock screw det B technological hole Fig 6 The user menu is called up by pressing and holding down the DEF microbutton and releasing it when the de...

Page 7: ...layer settings IP address 192 168 0 11 network mask 255 255 255 0 and the communication port for the control module To restore the default settings you should during the normal operation of the device press the microbutton and hold it down until the inscription R appears Hold the button down until the inscription R starts flashing and do not release it until the information default is displayed Re...

Page 8: ...e green light will be turned off 0x3A 0x20 0x47 on the signalling device the green light will be turned on the red light will be turned off 0x3A 0x3C 0x3E on the signalling device the red symbol of the left arrow and the green symbol of the right arrow will be turned on 0x3A 0x20 0x5E on the signalling device the red symbol turns off and the green symbol of the up arrow will be turned on Alpha cha...

Page 9: ... device det A det B det C LED module connectors det D RS 485 RS 422 connector det E 0 20mA digital current loop det F RS 232 connector det G Ethernet connector det H DEF microbutton det I housing earthing soldering point det J network power supply connector Fig 7 LED Module Connectors det A operator panel connector dry contact Fig 8 ...

Page 10: ...he light signalling device The connectors are accessible after the disassembly of the back cover and the LED module mounted on this cover det A device front det B controller det C back cover det D LED module Fig 9 NOTICE The housing should be disassembled with the power supply disconnected ...

Page 11: ... Ethernet TX Pin No 1 of RJ 45 TX Pin No 2 of RJ 45 RX Pin No 3 of RJ 45 RX Pin No 6 of RJ 45 Table 2 1 RS 232 connector For the communication purposes the user connects with the controller via the RS 232 connector Fig 7 using the control module 2 RS 485 RS 422 connector For the communication purposes the user connects with the controller via the RS 485 or RS 422 connector Fig 7 using the control ...

Page 12: ...the device to the mains power supply Step 4 The properly connected system will display the symbols in the light fields followed by the hard space symbol _ in the bottom field It means that the device is working according to the default protocol In 7 seconds the signalling device will go into the default display state Changing Ethernet Settings Wagset Software can be used to change the IP address T...

Page 13: ...ecycling The packaging elements must be segregated and then recycled in accordance with the local executive regulations on waste disposal Device disposal The device must not be disposed of as urban waste In accordance with the directive 2002 96 EC WEEE if the repair of the device is not economically justified the user must take the damaged or destroyed equipment to a special waste disposal Most co...