background image

 

IR-B02                                                                                                                                                        Page 8 

equipment and facility engineering 

 

 

4. Operating instructions 

 
Notes: 

 

Power supply: 1PH 230V 50/60HZ 

 

Do not touch the lens cap during and after curing to avoid 
burns. 
 

 
 
 
 
 
 
 
 
 
 
 
 

         

 

1.

 

Move the device and choose the optimal distance between emitter and car body. The 
optimal distance amounts approximately 30 – 50 cm. (When using the distance sensor: green 
light) 

2.

 

Adjust the direction of the emitters. They have to be aligned parallel to the car body. 

3.

 

Adjust the timer button (7) to set Pre-heating baking time. 

4.

 

Adjust the timer button (8) to set full baking time. 

5.

 

Turn on the power switch (11). 

6.

 

Turn on the switch for ultrasonic distance measuring device (6) and set the optimal distance. 
The optimal distance is reached, when the green indicator lights on (3). As required, you can 
also shut down and ignore this function. 

7.

 

Turn on emitter (9,10) to start work. 

8.

 

The machine stops automatically after the entered time. If you want to continue, restart the 
machine after cutting off the power some minutes. 

4.1 Curing times 

All values are only reference values. Discuss the exact times with your supplier !! 

Paint type 

Flash off 

Full bake (Minutes) 

Filler/Stopper 

--- 

5-7 

Primer 

--- 

6-8 

Hi-build 

--- 

10-12 

Solid-color 

--- 

11 

Clear coat 

--- 

12 

(1) red light: Distance is too close 
(2) yellow light: Distance is rather close 
(3) green light: Distance is suitable   
(4) yellow light: Distance is rather far 
(5) red light: Distance is too far   
(6) Switch for ultrasonic distance measuring device 
(7) Timer for pre-heating time 
(8) Timer for full baking time 
(9),(10) Start key  
(11) Power switch 

 

Summary of Contents for IR-B02

Page 1: ...Handleiding B TEC infrarooddroger BT IR B02 MSH equipment Appelmarkt 7 1681 PE Zwaagdijk Oost Tel 0228 561100 Fax 0228 561112 Mail info msh equipment nl Website www msh equipment nl Taal Engels...

Page 2: ...tion IR B02 Serial nr Construction year 2013 Parameters Rated voltage Rated current Rated frequency Rated power input Protection class Degree of protection 230 V 11 A 50 Hz 2040 W I IPX0 Tested accord...

Page 3: ...n 1 2 Safety regulations and maintenance advices 2 2 1 Work area 2 2 2 Use 2 2 3 Wartung und Pflege 3 2 4 Weitere Hinweise 3 3 Technical description of the machine 4 2 1 Technical information 4 2 2 Wi...

Page 4: ...ask you to read this document carefully before using the machine to reach maximum life and reliable operation Read this document carefully before commissioning and keep it for future reference The B T...

Page 5: ...nto the machine may lead to electric shock or damage to the machine For outdoor use please use the outdoor specific cables marked with W A or W for avoidance of electric shock Do not use this heater i...

Page 6: ...wires as soon as possible for avoidance of electric shock 2 3 Maintenance and care Regular cleaning of tubes and reflector panel should be done by using a piece of soft cloth or cotton with alcohol No...

Page 7: ...ht is adjustable from 40cm to 200cm 4 An electronic timer is adopted to time the baking 5 An ultrasonic distance measuring device is provided 2 1 Technical information 2 2 Wiring diagram Input current...

Page 8: ...IR B02 Page 5 equipment and facility engineering 2 3 Spare parts...

Page 9: ...B02 11 12 Panel B02 12 13 Control Box B02 13 14 Connectors Left and Right B02 14 15 AM12Adjustable Handle B02 15 16 Front Protective Net B02 16 17 Rear Protective Net B02 17 18 U shape Support B02 18...

Page 10: ...re 5 Remove the red plastic films from the emitter tubes and the stickers from the protection covers 6 Take out the red foam cubes behind the tubes Notes Power supply 11Amp 1 PH 230V 50Hz When adjusti...

Page 11: ...optimal distance The optimal distance is reached when the green indicator lights on 3 As required you can also shut down and ignore this function 7 Turn on emitter 9 10 to start work 8 The machine st...

Page 12: ...front of the emitter 5 Take out the defect tube and fix the new tube with same model number and wire the tube properly 6 Install the protective net radiating panel and the side panel Use a piece of so...

Page 13: ...ce Insufficient baking Too thick coating Make the machine closer Increase the baking time Thin the coating Difficult stains Too long baking Too near distance Shorten the baking Increase the distance F...