b-mola BM50 Operation Manual Download Page 3

04

03

Patented NCCO(Nano Confined Catalytic Oxidation)Air Purification Technology 

is invented by Member of HKUST Entrepreneurship Program, and has obtained 

global patents. Our technology can solve indoor air quality problems in an 

all-round way, create a home / office environment with fresh air, and protect you 

and your family's health.

NCCO Technology's Characteristics

◆  Patented NCCO Technology continuously removes bacteria and viruses efficiently. 
◆  Patented NCCO Technology effectively decomposes carcinogens in the air, such as formaldehyde. 
◆  Hazardous pollutants will be decomposed into harmless water molecule and carbon dioxide, and   
      will not accumulate in the filter, effectively avoiding re-release into the air due to saturation, and 
      will not cause secondary pollution. 
◆  Under normal maintenance conditions, NCCO Reactor can be used for a long time. Since there is no 
       need to replace NCCO Reactor frequently, the operating cost is much lower than similar products on 
       the market. 
◆  Effectively remove offensive odour. 
◆  Patented NCCO Technology has been widely used in different industries, such as schools, hospitals, 
      nursing centers and public toilets.

About Intelligent Power-Off Protection System

 

The unit will intelligently power off, as well as all extinguished indicators, after continuous use over a period of 8 

hours and then will restart automatically after 30 minutes downtime. During downtime, user can still restart unit by 

pressing ON / OFF Button. Our intelligent power-off system is able to effectively avoid excessive load and eliminate 

any risk during the supply of power.

■ 

Indoors

      

As dust falls on the floor, it is recommended to place the unit on a flat surface in the room.

■ Excellent Air Circulation

      

Placing the unit on a dry, solid, level surface, and ensure the unit is provided with reasonable space 

      of at least 15 cm from any objects, in order to operate effectively.

■ Do not put the unit in the following places:
   

 ·In the direct sunlight; blown by air conditioner; high temperature 

      area. (Otherwise, it may cause deformation, aging, discoloration 

      or reduction of service life.)

    ·Distance over 1 meter to objects such as televisions and radios. 

      (Otherwise, it may lead to image disorders and lost of sound.)

■ Do not place objects at air inlet and outlet. 

     (Otherwise, it may affect the operating performance.)

■ Do not use the same power outlet with TV, 

       radio and other equipment.

       

 (Otherwise, it may lead to image disorders 

        and lost of sound.)

      →Please plug into other power outlets.

■ Do not place any items on top of the unit. 

    

  (Otherwise, the unit may be malfunctioned.)

Basic Information

NCCO Technology

Patented NCCO Air Purification Technology Brings  Fresh and Clean Air

Placing Area Guideline

PRECAUTION

PRECAUTION

■ 

When any of the following situations occur, please stop operating the unit and    

     disconnect the power supply immediately.

    (Otherwise, it may lead to electric shock, fire or smoke.)

  · When the power line is moved, the unit stops operating.

  · If any control button fails.

  · If the circuit breaker works or the fuse burns out.

  · If the power line or plug is unusually hot.

  · If you notice burning odour or abnormal sound or vibration.

  · If there are any other abnormal phenomena or faults.      

 → 

Stop operating unit, pull out power plug, and contact Customer Service Centre or

      distributor for inspection and maintenance.

■ 

Please regularly clean the plug.

     (If there is dust and moisture on the plug, it may damage the insulation part of the plug 

     and cause fire.) 

  · Pull out the power plug and wipe it with a dry cloth.

  · Pull out the power plug when the unit is not used for a long time.

■ 

Make sure disconnect the power supply before maintaining the unit. 

      (Otherwise the unit may suddenly operate, resulting in electric shock or injury.)

■ 

Please insert the power plug completely into the power socket. 

      (Otherwise it may cause fire or electric shock if the power line is overheated.)

  · Do not use damaged power plugs or power sockets.

■ 

Please pull out the power plug at the hand plug position. 

(Otherwise, the  

      power line may  be damaged, resulting in fire or electric shock.) 

■ 

Do not place the unit in the following places:

  · Unstable place.

      (Otherwise the unit may be fall off, resulting in injury or damage to the unit.)

  · Bathroom, kitchen or other places with high humidity / temperature.

      (Otherwise the unit may be damaged or suffer from electric leakage, resulting in fire, 

       electric shock or personnel injury.)

  · Places where oil or flammable gas may leak. 

      (Otherwise fire may occur in the inhaled monitor, leading to fire.)

  · Near heater or other heat sources.

      (Otherwise the unit may be overheated, leading to fire disaster.)

■ 

Do not use gasoline or other volatile mixed solvents to wipe the unit.

      (Otherwise, the unit may rupture or short circuited, resulting in injury, fire or electric shock.)

■ 

Do not operating the unit while smoking pesticide is used. 

  · (Otherwise, the pesticide may accumulate in the unit and then released from the outlet, 

      endangering health.)

  · After using pesticide, the room should be ventilated thoroughly, before the unit can be operated.

■ 

Do not block the air inlet or outlet by placing clothes, books or other obstacles.

      (Otherwise, blocking the air outlet may lead to smoke and fire.)

■ 

Do not sit, stand or lean on this product.

      (Otherwise, the unit may be overturned, resulting in injury or unit damage.)

  · If children is around, please supervised carefully.

■Do not approach the unit with ignited cigarettes, incense and others.

      (Otherwise, flammables may be sucked into the unit and cause fire.)

■Do not spray flammable materials such as insecticides or air fresheners 

     around this product.

WARNING

Summary of Contents for BM50

Page 1: ...Safety Instructions before operation Page 2 3 Injury or property loss may occur if not operated according to this manual Please retain this manual for future reference Retain manual in reserve Please...

Page 2: ...nit may be short circuited and resulting in re or electric shock PROHIBITION MANDATORY MATTER Donotdisassemble repair ormodifytheunitonyourown Otherwiseitcouldresultin reorelectricshock Ifmaintenancew...

Page 3: ...r Placing Area Guideline PRECAUTION PRECAUTION When any of the following situations occur please stop operating the unit and disconnect the power supply immediately Otherwise it may lead to electric s...

Page 4: ...problem solution Display Screen AirSpeed ReduceButton AirSpeed IncreaseButton Eco Mode Button ON OFF Button Air Quality Indicator Control Panel I J A B C D E F G H Front Cover Pre lter HEPA Filter Fra...

Page 5: ...Button to turn o the unit and then turns it back on the unit would remain the same operation status as last usage 2 Default Air Speed Memory Function 3 Fan Speed Mode Reduce Speed Press the Reduce Spe...

Page 6: ...the concentra tion of PM2 5 TVOC CO2 The concentration display will maintain for 55 seconds until all indicators at Control Panel have been extinguished or there is further control For example if the...

Page 7: ...er or NCCO Reactor with water WARNING Cleaning Unit Body Use dry and soft cloth to clean the unit Damp cloth can be used to clean the surface of the unit Do not use abrasive materials ATTENTION 10 Aut...

Page 8: ...n a severely polluted area the treatment process will take longer It is recommended to use the HIGH FLOW MODE or extend the opera tional time until the pollution diminishes Q3 A The unit emits an unus...

Page 9: ...Check if the lters have been correctly installed Re install all lters The unit makes an abnormal noise The unit emits an unusual smell or smog e g smoke ame or burning The unit may malfunction Call th...