background image

 

RFM-TX1.1_RFM-TX2.1_QUG 

Quick User Guide 

v1.0 

RFM-TX1.1 / RFM-TX2.1

 

 

 

 

                                                         

   

 

868 MHz Wireless MBUS module for B METERS water meters 
 

Product description 

 

 

 

 

The RFM-TX1.1 / RFM-TX2.1 module is a device that allows to transmit the reading data detected by 
the RFM-series water meters manufactured by B METERS. 
The device must be configured by using the B METERING configuration software. This allows to set 
the working time, all the other working options and it allows to create devices lists. Please refer to the 
configuration software manual for a detailed description of the configuration features and options 
available.  

 
 

Package Content 

 

RFM-TX1.1 / RFM-TX2.1 module 

 

Anti-tampering seal 

 

Anti-tampering sticker 

 

Installation guide 

 
 

Technical data 

 

Working temperature: From +1°C to +55 °C 

 

Power supply voltage: Lithium battery  3.6V  Li-SOCI

2

 - 2,4 Ah (IP65); 3,8 Ah (IP68)* 

 

Maximum battery duration: 10 years** 

 

Radio interface: WMBUS EN14757-4 @868MHz [<10mW] – OMS Compatible 

 

Configuration: by using B METERING software and RFM-RX2 receiver 

 

Protection level: IP65 (on request IP68***) 

 

Transmission range: up to 300  meters**** 

 

Dimensions: Ø=67 mm x H=29 mm (IP65); Ø=67 mm x H=32 mm (IP68) 

 

Weight: 43g (IP65); 85g (IP68). 

 
* Batteries are not replaceable, DO NOT ATTEMPT TO REPLEACE. Any attempt will void the warranty, 
moreover will irreversibly damage the device. 
** The battery life strongly depends on the working time window, set during the configuration process, 
and  on  the  environmental  conditions.  Estimation  of  the  battery  life  is  given  by  the  configuration 
software. 
***IP68: maximum 24 hours of continuous submersion at 1 m depth  
****Under optimal propagation conditions, the radio range depends on physical conditions (building 
constructions, climatic conditions, …) where propagation of the radio signal can therefore vary.  

 
 

Installation 

The  installation  of  the  RFM-TX1.1  module  is  allowed  on  the  GSD8-RFM  meters  only  and  the 
installation of the RFM-TX2.1 module is allowed on the GMDM-RFM / GMDX-RFM meters. 
It is recommended to  install the RFM-TX1.1 / RFM-TX2.1 module away from metal  objects or any 
potential radio shielding, in an place protected from tampering. 
For its functioning, the device must be configured by using the B METERING software.

 

The installer 

has the task of checking the propagation conditions of the radio signal during installation. 

 
 

Commissioning 

Configure  the  radio  module  by  using  the  RFM-RX2  receiver  and  the  B  METERING  Software.  To 
complete the configuration process, press the red button located on the lower plate of the module. 
During the configuration process, the red LED will start to blink. The configuration can be considered 
as successfully completed when the red LED keeps blinking for 20 seconds or so. If the red LED blinks 
for a couple of seconds only, the configuration wasn’t successful and it will be necessary to repeat the 
procedure

For the complete configuration instructions, please refer to the software manual.

  

 

Once the configuration is completed, connect the module on the meter as shown in the picture. 
It is absolutely necessary to pair the optical index of the meter inside the hole placed on the plate of 
the module. 
With one hand, keep the meter rotating dial steady, with the  other hand press then carefully the 
module and turn it in a clockwise direction to lock it to the meter. 
Check on the reading software the correct data collection and check that no alarm is active. 
To avoid possible frauds on the module, it is possible to insert the orange seal in the two small holes 
placed on the left side of the module and apply an adhesive seal.  

 

RFM-TX1.1 IP65 installation: 

 

 

 

 

 

Step 1 

Step 2 

Step 3 

 

 

 

RFM-TX1.1 IP68 installation: 

 

 

 

 

 

Step 1 

Step 2 

Step 3 

 
 
 

 

RFM-TX2.1 IP68 installation: 

 

 

 

 

 

Step 1 

Step 2 

Step 3 

 

Safety

 

 

During  the  installation  process,  handle  the  device  with  care,  don’t  crush,  don’t  bent,  don’t 
exposure to electrostatic discharges which could damage permanently the device, do not install 
close to heat sources (radiators, conditioners, convectors etc..). 

 

The RFM-TX1.1 / RFM-TX2.1 module doesn’t contain hazardous materials in accordance with 
European  directives  91/157/EEC,  93/86/EEC,  and  2002/95/EC(RoHS).  The  device  requires 
specific disposal on the end of its lifetime. Recycling is mandatory or recommended following 
the Directive RAEE 2012/19/UE inside European Union region, or anyway dispose in accordance 
with local laws and regulations. Do not burn, or undergo to high temperatures.  

 

The  RFM-TX1.1  /  RFM-TX2.1  works  reliably  in  the  environmental  conditions  specified  in  this 
manual.  Any  unauthorized  intervention  and/or  modification  may  cause  malfunctions  or  total 
damaging of the product. 

 
 

Warranty 

The warranty period is set at 24 (twenty-four) months from the date of the shipping of the material. 
Warranty  is  against  defects  in  materials  or  workmanship  when  the  product  is  properly  used  and 
maintained  in  normal  efficiency.  This  Warranty  is  valid  and  enforceable  in  the  country  where  the 
product  was  purchased.  In  the  event  that  the  product  has  been  purchased  in  a  country  of  the 
European Union, the warranty is still valid in all countries of the Community. 
 
To obtain warranty service, it is requested to comply with the following clauses:  
1.

 

Products must be delivered for repair at the expense of the customer.  

2.

 

The product warranty will be subject to the exhibition of a tax document (receipt, receipt or 
bill of sale), which attests to the date of purchase of the product.  

3.

 

The repair will not affect the original date of expiration of the warranty and will not involve 
the renewal or extension thereof.  

4.

 

If at the time of the repair, the product has not any defect, it will be charged the costs of the 
technical analysis. 

5.

 

The warranty is void if the failure was due to: impacts, falls, misuse or abuse of the product, 
use of non-original batteries, accidents, product alteration, replacement/detachment of seals 
and/or product tampering. The same also does not cover damage caused during transport if 
packages used are unsuitable.  

6.

 

The warranty is not covering the battery of the product. 

7.

 

The  warranty  does  not  cover  the  inability  to  use  the  product,  other  costs  incidental  or 
consequential damages or other expenses incurred by the purchaser. 

8.

 

The warranty doesn’t cover damage to the product caused by usage in any other way than 
described in this manual. 

 
 

Support on the products 

If  the  product  needs  to  be  sent  to  the  technical  assistance,  contact  your  dealer  or  contact  the 
BMETERS After sales service at 

[email protected]

 

 
 

Declaration of Conformity 

Hereby,  B  METERS,  declares  that  this  RFM-TX1.1  /  RFM-TX2.1  is  in  compliance  with  the  essential 
requirements and other relevant provisions of Directive 2014/53/EU. 
The complete declaration can be downloaded from the official websit

www.bmeters.com

 
 
 

Contact Info 

 

B METERS Srl 

 

Via Friuli 3 
Gonars (UD) – 33050  
Italy 

Tel: +39 0432931415 
Fax: +39 0432992661 
E-Mail (sales/informations)

[email protected]

  

E-mail (technical support)

[email protected]

 

Web

www.bmeters.com

 

 

 

Reviews: