background image

 

RFM-MB1_RFM-MB2_QUG 

Quick User Guide 

v1.0 

RFM-MB1 / RFM-MB2

 

 

 

 

                                                         

   

 

Wired MBUS module for B METERS water meters 
 

Product description 

 

 

 

 

The RFM-MB1 / RFM-MB2 module is a device that allows to transmit the reading data detected by 
the RFM-series water meters manufactured by B METERS. 
The device must be configured by using the BMBUS configuration software and a MBUS master*. This 
allows  to  set  the  primary  address,  all  the  other  working  options  and  it  allows  to  perform  devices 
readings. 

To 

download 

the 

software, 

please 

connect 

to 

the 

following 

link 

http://www.bmeters.com/en/bm_product/m-bus-master/

 and  press the button “software”. Please 

refer to the configuration software manual for a detailed description of the configuration features 
and options available. 

 
 

Package Content 

 

RFM-MB1 / RFM-MB2 module 

 

Anti-tampering seal 

 

Anti-tampering sticker 

 

Installation guide 

 
 

Technical data 

 

Working temperature: From +1°C to +55 °C 

 

Power supply: MBUS network (+ backup Lithium battery  3V  Li-SOCI

2

**) 

 

Maximum battery duration: 1 year*** 

 

MBUS consumption: 1 unit load (≤1,5 mA) 

 

Communication interface: MBUS EN14757-2/3 

 

Configuration: by using BMBUS software and MBUS master 

 

Protection level: IP65  

 

Dimensions: Ø=67 mm x H=20 

 

Weight: 73g 

 
 

 

Installation 

The installation of the RFM-MB1 module is allowed on the GSD8-RFM meters only and the installation 
of the RFM-MB2 module is allowed on the GMDM-RFM / GMDX-RFM meters. 
It is recommended to install the RFM-MB1 / RFM-MB2 module in a place protected from tampering. 
For its functioning, the device must be configured by using the BMBUS software*.

 

The installer has 

the task of checking the correct data transmission during installation. 

 
 

Commissioning 

Configure the radio module by using BMBUS Software and a MBUS master*. Before proceeding with 
the configuration process, connect the module on the meter as shown in the pictures.

  

 

It is absolutely necessary to pair the optical index of the meter inside the hole placed on the plate of 
the module. 
With one hand, keep the meter rotating dial steady, with the  other hand press then carefully the 
module and turn it in a clockwise direction to lock it to the meter. 
Check on the reading software the correct data collection and check that no alarm is active. For the 
complete configuration instructions, please check the software manual. 
To avoid possible frauds on the module, it is possible to insert the orange seal in the two small holes 
placed on the left side of the module and apply an adhesive seal.  
Finally, connect the module in parallel with the MBUS network. 
 
 
 
*  It  is  also  possible  to  configure  the  device  by  using  a  custom  string,  software  and/or  master 
compatible with the MBUS standard EN14757-2/3. Contact 

[email protected]

 for further details. 

** Batteries are not replaceable, DO NOT ATTEMPT TO REPLEACE. Any attempt will void the warranty, 
moreover will irreversibly damage the device. 
*** When the device is disconnected from the BUS network 
 

 

Installazione RFM-MB1

 

 

 

 

 

 

Fase 1 

Fase 2 

Fase 3 

 
 
 
 
 
 
 
 
 
 
 

Installazione RFM-MB2

 

 

 

 

 

 

Fase 1 

Fase 2 

Fase 3 

 

Safety

 

 

During  the  installation  process,  handle  the  device  with  care,  don’t  crush,  don’t  bent,  don’t 
exposure to electrostatic discharges which could damage permanently the device, do not install 
close to heat sources (radiators, conditioners, convectors etc..). 

 

The  RFM-MB1  /  RFM-MB2  module  doesn’t  contain  hazardous  materials  in  accordance  with 
European  directives  2011/65/UE  (RoHS)  and  subsequent  modifications.  The  device  requires 
specific disposal on the end of its lifetime. Recycling is mandatory or recommended following 
the Directive RAEE inside European Union region, or anyway dispose in accordance with local 
laws and regulations. Do not burn, or undergo to high temperatures.  

 

The  RFM-MB1  /  RFM-MB2  works  reliably  in  the  environmental  conditions  specified  in  this 
manual.  Any  unauthorized  intervention  and/or  modification  may  cause  malfunctions  or  total 
damaging of the product. 

 
 

Warranty 

The warranty period is set at 24 (twenty-four) months from the date of the shipping of the material. 
Warranty  is  against  defects  in  materials  or  workmanship  when  the  product  is  properly  used  and 
maintained  in  normal  efficiency.  This  Warranty  is  valid  and  enforceable  in  the  country  where  the 
product  was  purchased.  In  the  event  that  the  product  has  been  purchased  in  a  country  of  the 
European Union, the warranty is still valid in all countries of the Community. 
 
To obtain warranty service, it is requested to comply with the following clauses:  
1.

 

Products must be delivered for repair at the expense of the customer.  

2.

 

The product warranty will be subject to the exhibition of a tax document (receipt, receipt or 
bill of sale), which attests to the date of purchase of the product.  

3.

 

The repair will not affect the original date of expiration of the warranty and will not involve 
the renewal or extension thereof.  

4.

 

If at the time of the repair, the product has not any defect, it will be charged the costs of the 
technical analysis. 

5.

 

The warranty is void if the failure was due to: impacts, falls, misuse or abuse of the product, 
use of non-original batteries, accidents, product alteration, replacement/detachment of seals 
and/or product tampering. The same also does not cover damage caused during transport if 
packages used are unsuitable.  

6.

 

The warranty is not covering the battery of the product. 

7.

 

The  warranty  does  not  cover  the  inability  to  use  the  product,  other  costs  incidental  or 
consequential damages or other expenses incurred by the purchaser. 

8.

 

The warranty doesn’t cover damage to the product caused by usage in any other way than 
described in this manual. 

 
 

Support on the products 

If  the  product  needs  to  be  sent  to  the  technical  assistance,  contact  your  dealer  or  contact  the 
BMETERS After sales service at 

[email protected]

 

 
 

Declaration of Conformity 

Hereby,  B  METERS,  declares  that  this  RFM-MB1  /  RFM-MB2  is  in  compliance  with  the  essential 
requirements and other relevant provisions of Directive 2014/30/EU. 
The complete declaration can be downloaded from the official websit

www.bmeters.com

 
 
 

Contact Info 

 

B METERS Srl 

 

Via Friuli 3 
Gonars (UD) – 33050  
Italy 

Tel: +39 0432931415 
Fax: +39 0432992661 
E-Mail (sales/informations)

[email protected]

  

E-mail (technical support)

[email protected]

 

Web

www.bmeters.com

 

 

 

Reviews: