868 MHz Wireless MBUS module for B METERS water meters 

Product descrip

on 

The 

IWM-TX5 

module is a device that allows to transmit the reading data detected by the GSD8-I 

water meters manufactured by B METERS. 

The device could be con

gured using an Android device with an NFC interface and the 

NFC IWM Con

applica

on.  

To download the app, please connect to the Google Play, type NFC IWM Con

g and press the bu

on 

“Install”.  Please  refer  to  the  con

gura

on  so

�w

are  manual  for  a  detailed  descrip

on  of  the 

con

gura

on features and op

ons available  

Package Content 

IWM-TX5 

module

An

-tampering seal 

An

-tampering s

cker 

Installa

on guide

Technical data 

Working temperature:  rom +1°C to +55 °C

Power supply voltage: lithium battery 3.0 v*

Maximum ba

�e

ry dura

�on:

 10 years**

Radio interface: WMBUS EN13757-4 @868MHz [<25mW], mode T1

Confi

guration: by app NFC IWM C

onfi

g

Protec

�o

n level: IP65 (on request IP68 ***)

Transmission range: up to 300 meters****

Dimensions (l x p x h): 70 x 90 x 30 mm

Weight: 124 g

* Ba

eries are not replaceable, DO NOT ATTEMPT TO REPLEACE. Any a

empt will void the warranty, 

moreover, will irreversibly damage the device. 

** The ba

ery life strongly depends on the working 

me window, set during the con

gura

on process, 

and on the environmental condi

ons. 

***IP68: maximum 24 hours of con

nuous submersion at 1 m depth 

****Under op

mal propaga

on condi

ons, the radio range depends on physical condi

ons (building 

construc

ons, clima

c condi

ons, …) where propaga

on of the radio signal can therefore vary. 

Installa

on 

The installa

on of the

 IWM-TX5 

module is allowed on the GSD8-I meters only. 

It is recommended to install the 

IWM-TX5 

module away from metal objects or any poten

al radio 

shielding, in a place protected from tampering. 

The device could be con

gured by using the NFC IWM con

g App.

 

The installer has the task of checking 

the propaga

on condi

ons of the radio signal during installa

on. 

Commissioning 

Make sure that you have respected the installa

on condi

ons described above. 

Connect the module on the meter as shown in the picture. It is necessary to pair the induc

ve index 

of the meter beneath the induc

ve sensor placed on the plate of the module. With one hand, keep 

the meter steady, with the other hand press then carefully the module and turn it in a clockwise 

direc

on to lock it to the meter. 

To ini

alize the module is necessary to let the induc

ve index of the dial rotate for 5 revolu

ons.  

Con

gura

on by using Android App + NFC Device

: to ini

alize the con

gura

on process, place the 

NFC  antenna  of  the  android  device  near  the  module  as  shown  in  the  picture.  For  the  complete 

con

gura

on instruc

ons, please refer to the app manual. 

Check on the reading so

�w

are the correct data collec

on and check that no alarm is ac

ve. To avoid 

possible frauds on the module, it is recommended to 

ghten the orange seal supplied and apply the 

adhesive seal. 

IWM-TX5 

Installa

on:

Step 1 

Step 2 

Step 3 

Seal applica

on: 

Step 1 

Step 2 

IWM-TX5 

con

gura

on/ac

va

on: 

  NFC con

fig

ura

on (op

onal) 

  Radio ac

va

on at the passage of 5 liters 

Safety

 

During  the  installa

on  process,  handle  the  device  with  care,  don’t  crush,  don’t  bent,  don’t

exposure to electrosta

c discharges which could damage permanently the device, do not install 

close to heat sources (radiators, condi

oners, convectors etc..). 

The 

IWM-TX5 

module  doesn’t  contain  hazardous  materials  in  accordance  with  European

direc

ves 91/157/EEC, 2006/66/EEC, 2013/56/EU and 2011/65/EU (RoHS). The device requires 

speci

c disposal on the end of its life

me. Recycling is mandatory or recommended following 

the Direc

ve RAEE 2012/19/UE inside European Union region, or anyway dispose in accordance 

with local laws and regula

ons. Do not burn or undergo to high temperatures. 

The 

IWM-TX5

  works  reliably  in  the  environmental  condi

ons  speci

ed  in  this  manual.  Any

unauthorized interven

on and/or modi

ca

on may cause malfunc

ons or total damaging of the 

product. 

Warranty 

The warranty period is set at 24 (twenty-four) months from the date of the shipping of the material. 

Warranty  is  against  defects in  materials  or  workmanship  when  the  product  is  properly  used  and 

maintained in normal e

ciency. This Warranty is valid and enforceable in the country where the 

product was purchased. If the product has been purchased in a country of the European Union, the 

warranty is s

ll valid in all countries of the Community. 

To obtain warranty service, it is requested to comply with the following clauses:  

1.

Products must be delivered for repair at the expense of the customer.

2.

The product warranty will be subject to the exhibi

on of a tax document (receipt, or bill of 

sale), which a

ests to the date of purchase of the product. 

3.

The repair will not a

ect the original date of expira

on of the warranty and will not involve 

the renewal or extension thereof. 

4.

If at the 

me of the repair, the product has not any defect, it will be charged the costs of the

technical analysis. 

5.

The warranty is void if the failure was due to: impacts, falls, misuse or abuse of the product, 

use of non-original ba

eries, accidents, product altera

on, replacement/detachment of seals 

and/or product tampering. The same also does not cover damage caused during transport if 

packages used are unsuitable. 

6.

The warranty is not covering the ba

ery of the product.

7.

The  warranty  does  not  cover  the  inability  to  use  the  product,  other  costs  incidental  or

consequen

al damages or other expenses incurred by the purchaser. 

8.

The warranty doesn’t cover damage to the product caused by usage in any other way than 

described in this manual. 

Support on the products 

If  the  product  needs  to  be  sent  to  the  technical  assistance,  contact  your  dealer,  or  contact  the 

BMETERS A

er sales service at 

[email protected]

.  

Declara

on of Conformity 

Hereby, B METERS, declares that this 

IWM-TX5 

is in compliance with the essen

al requirements and 

other relevant provisions of Direc

ve 2014/53/EU. 

The complete declara

on can be downloaded from the o

cial website 

www.bmeters.com

Contact Info 

 

B METERS Srl 

Via Friuli 3 

Gonars (UD) – 33050  

Italy 

Tel: +39 0432931415 

Fax: +39 0432992661 

E-Mail (sales/informa

ons): 

[email protected]

 

E-mail (technical support): 

[email protected]

 

Web: 

www.bmeters.com

 

Reviews: