HYDRODIGIT-S1

Digital single jet smart meter

OPERATING INSTRUCTIONS

Summary of Contents for HYDRODIGIT-S1

Page 1: ...EN HYDRODIGIT S1 Digital single jet smart meter OPERATING INSTRUCTIONS...

Page 2: ...AFETY INSTRUCTIONS 6 INSTALLATION REQUIREMENTS 8 OPERATION 9 DISPLAY 9 DELIVERY STATUS 9 OPERATING MODE RADIO ACTIVATION 9 RADIO PARAMETERS 9 DEVICE DISPLAY LOOP 12 ERROR MESSAGE 13 BATTERY AND REPLAC...

Page 3: ...Manual v1 4 5 HYDRODIGIT S1 Size mm in 15 1 2 15 1 2 20 3 4 L mm 80 110 130 B mm 85 85 85 I mm 160 190 228 D Threading in 3 4 3 4 1 H mm 73 73 73 h mm 18 18 18 L I B H D h CONTENT DESIGN According IS...

Page 4: ...olume 8 digits Serial Number Instant flowrate Reverse flow indication Test mode CE marking Approval number Manufacturer Maximum admissible pressure Temperature class Model End life expiration year IR...

Page 5: ...less MBUS v4 COMBO output configuration Wireless MBUS v4 only LoRaWAN COMBO output configuration LoRaWAN only LoRaWAN Wireless MBUS v4 COMBO output configuration LoraWAN Wireless MBUS v4 PACKAGING CON...

Page 6: ...trical safety and the RED Directive 2014 53 EU The warranty and correct functioning are void if the identification plate and seals applied to the instrument are removed or damaged It is forbidden to t...

Page 7: ...the possibility of exceeding the RF exposure limits human proximity to receivers with an integrated antenna should not be less than 20 cm 8 inches during normal operation Keep out of the reach of chi...

Page 8: ...pen and visible electronic unit Tampering by third parties or strong external impacts Report to the after sales service Consumption is not accounted Tampering by third parties strong external impacts...

Page 9: ...wM BUS radio is activated The display changes and the flow direction level appear if the flow rate is detected RADIO PARAMETERS Wireless MBUS compatible As soon as radio operation mode is activated t...

Page 10: ...data Transmitted data volume actual date and time reverse flow alarms It is possible to change the configuration parameters into Walk By mode with an USB to IR interface B METERS mod UC Cable and the...

Page 11: ...irectional but asynchronous transmission standard During this process the radio icon on the display will blink every second If the procedure is successful the icon will remain active and stable otherw...

Page 12: ...l data disabled Encryption enabled disabled Historical data 12 months Transmitted data depends on the selected parameters volume date and time reverse flow alarms leakage alarm date fraud alarm date Q...

Page 13: ...break If the flow rate of the meter stays continuously over Q3 for 30 minutes the alarm is set Check water network The alarm automatically resets when the flow rate decreases below 0 5 Q3 The payload...

Page 14: ...h could cause an explosion or a leak of gases or flammable liquids Always dispose of batteries in compliance with current regulations Always use original spare parts authorized by the manufacturer BAT...

Page 15: ...ct is not potentially dangerous for human health and the environment but if abandoned in the environment can have negative impact on the environment The crossed out wheeled dustbin symbol on the label...

Page 16: ...guration LoRaWAN Wireless MBUS EN 13757 4 Radio Frequency 868 MHz Radio range radio power Wireless MBUS 300 meters LoRaWAN 5 Km Battery life max 10 years IP68 maximum 24 hours of continuous submersion...

Page 17: ...r instructions used for the declaration OIML R 49 1 2006 EN 14154 1 2005 A2 2011 EN ISO 4064 1 2017 OIML R 49 2 2004 EN 14154 2 2005 A2 2011 EN ISO 4064 2 2017 OIML R 49 1 2013 EN 14154 3 2005 A2 2011...

Page 18: ...ODIGIT S1 MANUFACTURER ADDRESS B METERS srl Via Friuli 3 Gonars 33050 UD ITALY Tel 39 0432 931415 Tel 39 0432 1690412 Fax 39 0432 992661 E mail sales info info bmeters com E mail support ticket bmeter...