![B.M.P. DYNAMICROLL Use And Maintenance Manual Download Page 17](http://html1.mh-extra.com/html/b-m-p/dynamicroll/dynamicroll_use-and-maintenance-manual_461567017.webp)
Operating instructions
Use and maintenance manual
ON
4
RELEASE STOP BUTTON (LED 6 turned on)
5
YOU CAN NOT COMPLETE THE
SETTING OF THE RESISTIVE
EDGE
5
VERIFY THAT THE JUMPER ON THE
TRANSMITTER J1 IS TAKEN OFF
5
RESET THE OLD CODES (close the jumper "MR"
press the PROG button until you hear a beeps tight
series, then remove the jumper)
5
VERIFY WITH THE TESTER THE CHARGE OF THE
TRANSMITTER BATTERIES
5
VERIFY IF THE RESISTENCE(8.2 K
Ω
) FOR THE
CABLES THAT COME OUT FROM THE EDGE
CHANGES IF YOU PRESS THE EDGE if it doesn’t
change control that the resistive band is perfectly flat
for all the length of the black profile or take out the
gum and control the
5
VERIFY THE CONNECTIONS OF THE RECEIVER
6
THE PHOTOCELL DOESN’T
WORK ( LD 7 OFF)
6
VERIFY THE ALIGNMENT
6
VERIFY THE CONNECTION OF THE BLACK
RECEIVER CABLE( brown +12Vdc) (blue 0V dc ) (
black: signal that it arrives to the terminal 14 in the
local plant)
(the door doesn’t close )
6
VERIFY THE CONNECTION OF THE
TRANSMITTER GREY CABLE ( brown +12Vdc) (blue
0V dc)
( ATTENTION! If you invert the brown and blue cables
you will damage the sensors)
7
THE ANTI-JAMMING SENSOR
DOESN’T WORK (sensor)
7
VERIFY THE CONNECTION ( brown +12Vdc) (blue +
white 0V dc ) ( black: signal that it arrives to the
terminal 7 in the local plant)
(the sensor doesn’t light up)
8
THE ANTI-JAMMING SENSOR
8
BRING THE SENSOR CLOSER TO THE CURTAIN