background image

40429 Brickyard Drive • Madera, CA 93636 • USA

559.438.5800 • FAX 559.438.5900 

www.bklighting.com • [email protected]

B-K LIGHTING

PROJECT:

TYPE:

IMPORTANT SAFETY INFORMATION LISTED ON REVERSE

READ, FOLLOW, AND SAVE ALL SAFETY AND INSTALLATION INSTRUCTIONS

RELEASED

4-30-18

REFERENCE

 

NUMBER

INS-2109-00

CATSKILL™

 SERIES

PAR 20 Halogen Installation Instructions

WIRING DIAGRAM

Phase 1 - Rough In

Installation of Back box

1.  Install Conduit (By Others) to be used with 

this product. 

2.  Install junction box (By Others) so that front 

face is flush with finished wall. Seal building 

envelope as per NEC.

3.  Connect box to conduit and pull wires for 

connections (See wiring diagram).

Additional Info

•  Please follow National and Local electrical codes for your area. 
•  4” round cast box is provided with Five (5) 1/2” threaded hubs for 

conduit entry (4 on sides and one on back of box). 

•  Suitable for through wire
•  Suitable for installation into combustible materials.
•  Rated for 90° C.
•  Junction box, universal mounting ring screws, box mounting hardware 

and gaskets (By Others)

3.  Mount fixture using two (2) #10-24 hex screws 

to installed back box using 1/8” Allen wrench.  

Seal building envelope as per NEC.

 

Do not 

overtighten.

Phase 2 - Finish Installation of Fixture

1.  Install universal mounting ring (supplied with 

fixture) using #10-24 screws onto back box. Align 

fixture mounting holes to final mounting position. 

2.  Make connections with branch circuit wiring to 

fixture leads using proper wire connectors (By 

Others). Connect grounding wire to ground 

wire from fixture. 

See wiring diagram.

120V

120V

Fixture

COM

GROUND

COM

GROUND

Reviews: