40429 Brickyard Drive • Madera, CA 93636 • USA
559.438.5800 • FAX 559.438.5900
www.bklighting.com • [email protected]
B-K LIGHTING
3. Mount faceplate using two (2) #10-24 screws
with 1/8” Allen wrench. Tighten to compress
gasket. Do not over tighten.
Phase 2 - Finish Installation of Fixture with Remote Transformer
1. Remove #10-24 Phillips screws from mounted
back box. Install universal mounting ring (supplied
with faceplate) using #10-24 screws onto back box.
Align faceplate mounting holes to final mounting
position.
2. Make watertight connections from remote
transformer to fixture leads using waterproof
wire connectors (By Others).
See wiring
diagram.
Phase 1 - Rough In
Installation of Back box
1. Install Conduit (By Others) to be used with
this product.
2. Install junction box so that front face is flush
with finished wall or ceiling.
3. Connect box to conduit and pull wires for
connections (See Wiring diagram).
Additional Info
• Please follow National and Local electrical codes for your area.
• 4” round cast box
• Suitable for through wire.
• Suitable for installation into combustible materials.
• Rated for 90° C.
IMPORTANT SAFETY INFORMATION LISTED ON REVERSE
READ, FOLLOW, AND SAVE ALL SAFETY AND INSTALLATION INSTRUCTIONS
RELEASED
7-13-16
REFERENCE
NUMBER
INS-1496
LINE
12V
Fixture
COM
Remote
Transformer
COM
WIRING DIAGRAM
BACK BOX
Low Voltage Halogen
Installation Instructions