ALTAIR

YOKE MOUNT

Standard Installation

2.  Line up fixture yoke to mounting location and 

secure with 3/4-10 hex bolt with adjustable 

crescent wrench.

Yoke Mount Installation

1.  Prepare for installation for yoke location. 

Clearance hole is 9/16” diameter.

9/16” Dia.

WIRING DIAGRAM

3.  Make watertight connections using waterproof 

wire connectors to connect incoming primary 

wiring to integral driver wiring as per NEC. 

Secondary side is factory wired. 

See wiring 

diagram.

HOT

LED

NEUTRAL

GROUND

HOT

NEUTRAL

GROUND

Inte

gr

al

DRIVER

+

-

0-10V -

0-10V +

0-10V -

0-10V +