background image

 

Top limit

Bottom limit

Delay time

>200 Lux

30 s

<200 Lux

>100 Lux

15 s

<100 Lux

>50 Lux

7 s

<50 Lux

Immediate activation

B.E.G.

‘s Smarthome devices may not be opened! Please contact Brück 

Electronic GmbH in the event of a fault with your device.

13. Technical data

14. Important information

!

Please stay within the specified power limits with connected consumers so 

as to prevent Smarthome actuators from overloading. 

Overloading may destroy the devices, result in personal injury and may 

even cause fire.

!

Brück Electronic GmbH (

B.E.G.

) herewith declares that the devices described meet the fundamental requirements  

and fulfil other relevant regulations set out in the R&TTE Directive 1999/5/EC.

The full declaration of conformity is available at:

http://www.luxomat.com

under "Support" in the "Download" section 

 

 

 

 

 

 

 

Brück Electronic GmbH

Schlosserstraße 30

51789 Lindlar

Please do not plug several Smarthome plug socket actuators behind each 

other into a single plug socket.

!

Take the device immediately out of operation should it become defective or 

if damage becomes apparent!

!

Article may only be installed by a qualified electrician!

!

Recommended  

mounting height:

  

2 - 3 m

Transmission and  

reception frequency: 

  868,42 MHz

Transmission power:

   <10 mW

Transmission and  

reception range  

(open area)

:  

max. 100 m

Lux values:

  

2 - 2500 Lux

Time setting:

  

15 sec. - 16 min./ test

Dimensions:

 

L 121 x W 71 x H 85 mm

  

Declaration: 

The product meets the Low 

Voltage Directive 2006/95/EC and the EMC 

Directive 2004/108/EC.

Sensor and power supply in one case

Voltage: 

 230 V~ 

±

10 %

Terminals: 

 

for single core  

 conductors

Ambient temperature:

   -15°C - +50°C

Power consumption:   < 

0,5 W

Protection class: 

2  

Protection: 

IP54

Settings:    

 Rotary control or  

remote control

Detection range:

  

 230°, additionally 

360° Under-creep 

protection function

Range:

 ca. 

20 m 

MAN

-SM 7

72

7 –0

50

913–1

12. Delay times 

The device has various delay times for the change between light and dark

in order to prevent repeated switching on and off at light values that are close to the switching values.

Bild-BA-RC-plus-next-230-ZW_050913_GB.indd   5

05.09.2013   10:01:17

Summary of Contents for RC-plus next 230 ZW

Page 1: ...orks D D D max 100 m D max 30 m 230 20 m 2 0 m 6 m 2 50 m 4 m 1 3 2 3 Suitable installation locations 15 C 50 C quer zum Melder gehen frontal zum Melder gehen Unterkriechschutz Walk at right angles to the detector Walk towards the detector Creep zone protection 1 2 3 4 Installation 1 3 2 Connector base Cable entry point min 0 5 m TEST 16 12 8 4 15s 30s 1 1 5 2 3 5 6 7 10 2 1 10 3 Programming butto...

Page 2: ...ay Creating groups Please refer to the MyControl operating instructions 7 Taking the device into operation A Connection with MyControl 5 sec 10 sec 15 sec 20 sec 25 sec 30 sec 35 sec Home ID x Time LED Status Slave Slave Home ID x Registration of additional control devices possible Max 1 2 1 sec Registration priority 1 Master MyControl 2 Actuators 3 Motion presence detectors 1 Connecting devices C...

Page 3: ...TEST S Lux 300 Lux 50 Lux 10 B E G LUXOMAT 10 min S LED IR SMARTHOME B E G LUXOMAT 1CH 2CH RESET Settings with Or may be set manually with works program 5 min 300 Lux or 30 min 15 min 1000 Lux 500 Lux min 5 Alarm min 1 min 2 1 TEST S Lux 300 Lux 50 Lux 10 B E G LUXOMAT 10 min S LED IR SMARTHOME B E G LUXOMAT 1CH 2CH RESET f f Programming concluded i f f Note Selecting very high sensitivity may re ...

Page 4: ...get light value Continued running time Permanently deactivate the LEDs on the device 12 hour party mode Light on for 12 hours Activating testing mode when closed Deactivation Press reset Resetting when closed End testing mode Accept standard settings Switch light on off 1CH mode Alarm function This key opens the detector to allow the following functions to be programmed Attention The detector will...

Page 5: ... socket actuators behind each other into a single plug socket Take the device immediately out of operation should it become defective or if damage becomes apparent Article may only be installed by a qualified electrician Recommended mounting height 2 3 m Transmission and reception frequency 868 42 MHz Transmission power 10 mW Transmission and reception range open area max 100 m Lux values 2 2500 L...

Reviews: