LED function display during the self-testing cycle (approx. 60 s)

Function

Zone left LED1 (red) 

Zone right LED2 (red)

Zone UKS LED3 (red) 

Programming-LED (red)

Self-testing cycle reprogrammed 

after power from the mains has 

been switched on

All 3 LEDs flash simultaneously

Self-testing cycle reprogrammed 

after power from the mains has 

been switched on

LEDS flash rapidly

Self-testing cycle double-locked 

after power from the mains has 

been switched on

All 3 LEDs will each flash at one-second intervals for 80 ms

LED function display during operation

Motion detection

LED will flash when a motion is 

detected

LED will flash when a motion is 

detected

LED will flash when a motion is 

detected

Party mode active

Red and green LEDs will flash alternately for 0.5s

Registration

LED will flash during the registra

-

tion process

Initialization 

The LED will light up continuous-

ly after successful initialization 

(key pressed for longer than 3 s) 

until it is released

IR command

The 3 LEDs will flash once

11. LED function display

2. 1CH/2CH channel settings

Option 1 (1CH)

1CH

Simultaneous Switching

Mains Switching

Wireless - Lux and Motion

Target brightness value
Day mode: 

Light sensor inactive, switches at every brightness /

  

Night mode: 

Very low activation value of around 10 lux

Automatic reading in of the current light value as the new target light value

Continued running time

Permanently deactivate the LEDs on the device

12-hour party mode: 

Light on for 12 hours

Activating testing mode when closed 

Deactivation: 

Press reset

Resetting when closed 

End testing mode 

Accept standard settings

Switch light on/off

1CH mode

Alarm function

This key opens the detector to allow the following functions to be programmed. 

Attention:

 The detector will be automatically closed

• 

each time the power is switched back on

• 

or after 3 min. 

Condition is changed, „closed“. 

The white LED will flash every 0.5 seconds in the first 5 seconds.  

Sabotage prevention may be activated during this time.

Permanent sabotage prevention 

First open the device, then close the device, LED will light up for 5 seconds  

Sabotage prevention may be activated during this time. Either carry out a reset 

(see Point 4) or proceed as follows to exit this mode: 

 

  

1. Interrupt the power 

2. Apply power for 31 to 59 seconds 

3. Interrupt the power again 

4. Apply power 

5. Open the detector

max

50

Lux

1500

Lux

ON

OFF

t < 5 s

10

Lux

����

���

min

1

��

���

1CH

Alarm

10. remote control IR-SMARTHOME

Unlocking the device

or

or

or

to

optional

or

Locking the device

Deactivate LEDs

Permanent sabotage 

prevention 

10

Lux

����

���

��

���

Reset when open: 

Deletion of all values 

set with the remote 

control, potentiometer 

settings will apply.

max

50

Lux

1500

Lux

ON

OFF

t < 5 s

max

50

Lux

1500

Lux

ON

OFF

optional

30

min

15

min

1000

Lux

500

Lux

min

5

Alarm

min

1

min

2

1

TEST

+

S

Lux

300

Lux

50

Lux

10

B.E.G.

LUXOMAT

®

10

min

S

LED

IR-SMARTHOME

B.E.G.

LUXOMAT

®

1CH

2 CH

RESET

2C H

1

Bild-BA-RC-plus-next-230-ZW_050913_GB.indd   4

05.09.2013   10:01:17

Summary of Contents for RC-plus next 230 ZW

Page 1: ...orks D D D max 100 m D max 30 m 230 20 m 2 0 m 6 m 2 50 m 4 m 1 3 2 3 Suitable installation locations 15 C 50 C quer zum Melder gehen frontal zum Melder gehen Unterkriechschutz Walk at right angles to the detector Walk towards the detector Creep zone protection 1 2 3 4 Installation 1 3 2 Connector base Cable entry point min 0 5 m TEST 16 12 8 4 15s 30s 1 1 5 2 3 5 6 7 10 2 1 10 3 Programming butto...

Page 2: ...ay Creating groups Please refer to the MyControl operating instructions 7 Taking the device into operation A Connection with MyControl 5 sec 10 sec 15 sec 20 sec 25 sec 30 sec 35 sec Home ID x Time LED Status Slave Slave Home ID x Registration of additional control devices possible Max 1 2 1 sec Registration priority 1 Master MyControl 2 Actuators 3 Motion presence detectors 1 Connecting devices C...

Page 3: ...TEST S Lux 300 Lux 50 Lux 10 B E G LUXOMAT 10 min S LED IR SMARTHOME B E G LUXOMAT 1CH 2CH RESET Settings with Or may be set manually with works program 5 min 300 Lux or 30 min 15 min 1000 Lux 500 Lux min 5 Alarm min 1 min 2 1 TEST S Lux 300 Lux 50 Lux 10 B E G LUXOMAT 10 min S LED IR SMARTHOME B E G LUXOMAT 1CH 2CH RESET f f Programming concluded i f f Note Selecting very high sensitivity may re ...

Page 4: ...get light value Continued running time Permanently deactivate the LEDs on the device 12 hour party mode Light on for 12 hours Activating testing mode when closed Deactivation Press reset Resetting when closed End testing mode Accept standard settings Switch light on off 1CH mode Alarm function This key opens the detector to allow the following functions to be programmed Attention The detector will...

Page 5: ... socket actuators behind each other into a single plug socket Take the device immediately out of operation should it become defective or if damage becomes apparent Article may only be installed by a qualified electrician Recommended mounting height 2 3 m Transmission and reception frequency 868 42 MHz Transmission power 10 mW Transmission and reception range open area max 100 m Lux values 2 2500 L...

Reviews: