3. Putting into operation / Settings
Follow-up time for light control
Thetimecanbesetinfinitelyvariablyatbetween
1and30minutes.
SymbolTEST:Testmode(Everymovementswitches
onthelightforaperiodof1second,switchingit
offforaperiodof2secondsafterthatregardless
ofthelevelofbrightness)
Twilight-switch for light control (relay 1)
Theswitch-onvalueforthelightcanbesetatbe-
tween10and2000Lux.Usingtherotarycontrol,
theluminancesetpointscanbesetasdesired.
Symbol : Night-timeoperation
Symbol :Daytime/Night-timeoperation
Orientation lighting
Thisrotarycontrollerservestodeterminethework-
ingtimeoftheorientationlighting(fixedto20 %).
“ON”forpermanentorientationlighting.
“OFF”fordeactiviationoforientationlighting.
Installation and Operating Instruction for B.E.G. - Occupancy detectors PD4-M-DIM-C-SM/-FC/-FM
4. Settings carried out using remote control (optional)
Remote control LUXOMAT
®
IR-PDim
1. Check Battery:
openbatterycompartmentbypressingtheplastic
springstogetherandremovingthebattery-holder.
2. IMPORTANT
Pleasepayattention,thatthesettingisPotentio-
meter1at“TEST”andPotentiometer2
not
at
“SUN”.Allvalueswhichhavebeenprogrammed
usingtheremotecontrolwillbedeletedinthe
eventofpowerfailureintheposition“TEST/
SUN”.PleaseswitchPotentiometer2overto
“MOON”oranyothervalue.
Caution:
Settingswithremotecontrolsupersedethe
settingsbycourtesyofpotentiometers.
1. Mounting preparations
Work on the 230 V mains supply
may only be carried out by quali-
fied professionals or by instructed
persons under the direction and
supervision of qualified skilled elec-
trical personnel in accordance with
electrotechnical regulations.
Disconnect supply before installing!
WheninMaster/Slavemodeof
operation,theMaster-appliance
mustalwaysbeinstalledatthe
locationwherethereisleast
daylight.
Lock device
Test mode
Resettodeactivate
Resetting when closed
Thelightingrelayisswitchedoff,i.e.
openedandthefollow-uptimesreset.
Permanent protection against sabotage
Thisfunctionblockstheunitpermanently(greenLEDis
illuminated).Thisoperatingmodecanonlybeactivated
duringtheperiodof5secondsafterpressingthe“lock“
button.Thisstatuswillonlypermitactuatingthefunction
“Lighton/Lightoff”.
Theprocedureforleavingthismodeisasfollows:
1.Switchoffthecurrent
2.Applycurrentfor31-59seconds
3.Switchofthecurrentagain
4.Applycurrent
5.Opendetector
Light on/off => (see page 2, point 9)
Thelightwillremainswitchedon/offforaslongasmove-
mentsaredetectedintheareasofcoverage.Oncethelast
movementhasbeendetected,thelightwillremainonfor
thedurationofthefollow-uptimeaspersetting.
Theappliancewillthenreturnindependentlytothemode
selected(FullyorSemi-automatic).
B.E.G. (UK) Ltd.
QWest
GreatWestRoad
Brentford,Middlesex
TW80GP
Tel:
0870.8505412
Fax:
0870.8505413
E-Mail: [email protected]
Internet: www.beg-luxomat.com
Option:
Wall bracket for remote
control IR-PDim
Theproductentersaninitial60-sec-
ondself-testcycle,whenthesupply
isfirstconnected.Theoccupancy
detectorisreadyforoperation.
2d. Self test cycle
B.E.G.
LUXOMAT
®
PD4-M-DIM-Corridor
Thedetectorcanbe
installedinconventional
inlet-socketsmountedon
theceiling.
Theassemblyplate
enclosedmustbestripped
offpriortoinstallation
andsecuredtotheceiling
using4screwsandensur-
ingthatitisnotlaterally
transposed.
(Pleaserefertotheconnec-
tiondiagramsonpage2
oftheOperatingInstruc-
tionswhenconnectingup
thewiring)
2a. Installation of the LUXOMAT
®
PD4-M-DIM-C-SM
2c. Installation of the LUXOMAT
®
PD4-M-DIM-C-FM
2b. Installation of the LUXOMAT
®
PD4-M-DIM-C-FC
Thedetectorhas
beendesignedand
developedspecifically
forinstallationinsus-
pendedceilings.
Acircularopeningof
diameter68-70 mm
mustfirstofallbepro-
ducedintheceiling.
Havingconnectedupthecablesinaccord-
ancewithregulations,thedetectorisinserted
intotheopeningasshowninthedrawing
oppositeandfixedintopositionwiththeas-
sistanceofthespringclip.
ATTENTION:
Formaximum
sensitivitythedetector-,
lens-andcorridor-axismust
match.
Thedetectormustbeinstalledonasolidandlevelsurface.
Thecircularcoverringmustberemovedpriortoassembly.
Todothis,twistthelens(C)anticlockwisethroughapproxi-
mately5°andliftoff.
Havingconnectedupthewiresinaccordancewithregula-
tions,securethedetectorwith2screws.Afterinstallation
replacethelensandlock(turnclockwise).Mainstobe
connected
.
open
close
opened
closed
Unlocking device
Lock device
Luminance set point for constant light regulation
Dimming
Thefollowingapproachwillproveusefulwhensettinga
commandvalue(exampleworkplace):Placealuxmeterflat
onthedesk,then,usingtheremotecontrolIR-PDim,adjust
thelightupordownbypressingthekeysmaxorminuntil
thedesiredcommandvaluewhichbestsuitsyourrequire-
mentshasbeenreached.
Automatic reading in the current light value
as new luminance set point
Individuallightvalue2-2500Lux
Follow-up time
1upto30min.
Orientation lighting and its follow-up time
OFF button:
Noorientationlight
Grey button:
Programmingtheswitch-offdelaytime
On button:
Orientationlightispermanentlyactivated.
Note:
Duringtheorientationlightphase,theconstantlight
regulationisalsoactive:ifthereissufficientbrightness,
dimmingoccurs<2 Vand,ifapplicable,thelightingis
switchedoff.
Preset/user mode => (see page 2, point 6)
Fully automatic/semi automatic mode => (see page 2, point 5)
Semiautomatic:greenLED,
Fullyautomatic:redLEDonforca.3sec.
Resetting when open
Allvalueswhichhavebeenprogrammedusingtheremote
controlIR-PDimaredeleted,andthosevalueswhichhave
beensetbypotentiometerareactivated.
max
50
Lux
1500
Lux
ON
OFF
max
50
Lux
1500
Lux
ON
OFF
max
50
Lux
1500
Lux
ON
OFF
max
50
Lux
1500
Lux
ON
OFF
max
50
Lux
1500
Lux
ON
OFF
max
50
Lux
1500
Lux
ON
OFF
max
50
Lux
1500
Lux
ON
OFF
max
50
Lux
1500
Lux
ON
OFF
max
50
Lux
1500
Lux
ON
OFF
20 %
max
50
Lux
1500
Lux
ON
OFF
120 6050
40
30
15
10
A
16 10
5
2
1
30
15
TEST
2000
1200
600
200
40
5
60
5
10
30
50
ON
OFF
25 22
18
16
10
3
1
TEST
6
30
R1
B.E.G. Brück Electronic GmbH
Schlosserstr.30
51789Lindlar
Tel:
02266.901210
Fax:
02266.45092
E-Mail:
Internet: www.beg-luxomat.com