notice:

Commercially available stairway-lighting timer-

switches differentiate according to the type and 

manner in which the neon glow-lamp push button 

is energized.

There are models available with integrated half-

wave or full-wave rectification.

As the 

LUXOMAT

®

 Indoor 180-SC uses the result-

ing neon glow-lamp supply to power itself, this 

determines the current consumption and thus the 

max. possible number of the 

LUXOMAT

®

 Indoor 

180-SC’s.

Caution:

 

Full-wave rectification leads to greater dissipation 

power-loss and thus to the 

LUXOMAT

®

 Indoor 

180-SC becoming heated-up.

The following list does not claim to be complete. 

The models listed are only given as examples:

Stairway lighting-timer

U-button

Indoor 180-SC

HAGER EM001N

50 Hz

ca. 4 mA 

–> ca. 20 x Indoor180-SC

EBERLE ITZ50

100 Hz

ca. 8 mA 

–> ca. 4 x Indoor180-SC

attention: 

For technical reasons, we recommend the 

use of above-mentioned staircase lighting automates.

7. Electromagnetic compatibility

It cannot be excluded that spurious triggering can 

be caused when placed directly in the area of 

strong radio transmitters (e.g. radio operators, taxi 

control centres, cell phones etc.).

However, these phenomena do not cause any 

defects in the sensor technology. If such spurious 

triggering does occur, the 

LUXOMAT

®

 Indoor 

180-SC automatically switches off after the source 

of HF interference has disappeared. 

8. Detection area

9. Trouble shooting - Practical hints

1. Lamp does not light up

- Tungsten halogen lamp defective

Replace tungsten halogen lamp

- No mains connection

Check connection by qualified electrician

- Incorrect setting of lux level

Correct setting of lux level

- Unit mounted too high

Mount at recommended height

-  PIR detector lens obstructed by dirt or other 

objects

Clean lens or remove objects

- Main fuse defective

Check or replace by qualified electrician

2. Delayed lamp activation

- Mounted too high

Mount at height stated in specification  

(

1.10 - 2.20 m

)

- Direct line of approach

Re-direct walking so that the approach is not 

frontally

3. Lamp stays on continuously

-  Continual thermal activity detected ie. extractor 

fan, central heating ducts

Check for any activity which could cause unit 

detection to be maintained

- Delay time set too high

Reduce time delay
Check ambient noiselevel, if necessary switch off 

noisesources

4.  Limitation of range  

(not up to the minimum specification)

- Mounted too high

Correct mounting height

-  Temperature difference between ambient tem-

perature and source of heat too small

No improvement possible

-  Direction of movement aimed directly at lens of 

motion detector

Move laterally to detector

•  Settings of the operating time and twilight value.

• Mount covering-cap

 (F)

•  The covering-cap 

(F) 

can be removed as shown 

in the drawing.

For outdoorinstallations additionally the IP54-acces-

sory- fixing-set has to be mounted (Part nr. 92139). 

4. Adjustment - Rotary control

4.1 Twilight threshold value:

 

The lighting actuator value can be preset

 

between 5 and 2000 Lux

 

  Night setting

  Day/night operation

4.2 Suppressing the twilight threshold-value query

 

The suppression time can be set from 

 

ca. 1min. to 10 min.

5. Wiring diagrams:

6. Technical data

• Operating voltage  via the stairway lighting- 

 

timer 230 VAC

• Power consumption  ca. 4 mA /230 VAC
• Impulse duration 

0.1 sec.

• Impulse switching capacity   

 

max. 200 mA /230 VAC

• Detection area 

180° horizontal

 

ca. 60° vertical

• Detection range at 1,10 - 2,20 m installation 

   height:  

   max 10 m during sideways passing

   ca 3 m during direct approach
• Twilight threshold value 

ca. 5 - 2000 Lux

• Twilight threshold-value suppression 

 

 

ca. 1min. - 10 min.

• Dimensions L x W  87 x 87mm

   Installation depth   36 mm
• Protection 

 IP20, II  

(with accessory IP54)

• Housing  

 UV- and shock-resistant 

Polycarbonate

Detection area Indoor 180

Side view

                                          

Top view

Walking across

Walking towards

 3 m

Erfassungsbereich Indoor 180

Montagehöhe 1,1 - 2,2 m                     Seitenansicht

 8 m

 3 m

                                          Aufsicht

 Gehen quer zur Erfassungsrichtung

 frontales Gehen

 3 m

Mounting height  1.10 - 2.20 m                     

 10 m

 3 m

4.1

4.2

LED

C

A2         B

a1         4

L         

n   

indoor180-SC

f. ex.: 4-wire-system 

recommendation

max. 10 Indoor180-SC

indoor180-SC