12. Technical data

Power supply:

    

110-240 VAC, 50/60 Hz

Power consumption:

  

approx. 1W

Ambient temperature

  

-25°C to +50°C

Degree of protection/class:

  IP20 / II

Recommended height

for mounting:

    

2 - 3 m

Range of coverage 

Ø H 2,5 m / T = 18°C:

 

seated 4 m / tangential 10 m / 

 

 

 

radial 6 m

Area of coverage:

  

circular 360°

Dimensions H x Ø [mm]

 

      FC 

 

 

 

84.5 x 80 mm

Visible part when built into ceiling:

 15 x 80 mm

Lux value:

  

 

10 - 2000 Lux

• DALI/DSI

digital BUS control wire, 2-core, no polarity (broadcast only)

Max. no. of series-connected electronic ballasts: 

  

 

up to 50 (broadcast only)

Time settings:

    

1 - 30 min. / test

• Channel 2

Type of contact:   

 

NOC/with pre-travel tungsten 

contact

Contact load:

     

2300 W, cos

ϕ

 =1;  

 

1150 VA, cos

ϕ

 = 0,5, µ contact

 Declaration of Conformity:  

This product respects the directives concerning 
1. electromagnetic compatibility (2004/108/EU)
2. low voltage (2006/95/EU)
3.  restriction of the use of certain hazardous substances in electrical 

and electronic equipment (2011/65/EU)

13. Article / Part nr. / Accessory

Typ

FC

PD2-M-DALI/DSI-1C (Master)

92486

PD2-S (Slave)

92166

LUXOMAT

®

 Remote control:

IR-PD-DALI-1C (incl. wall bracket)   

92116              

IR-PD-DALI-Mini 

92112

IR-RC-Adapter with smartphone app 

92726

Accessories:

BSK Wire basket                     

92199

14. LED function indicators

LED function indicators

Process

Standard 

mode

Double-locked

Initialisation time

unprogrammed

Red flashes

Green flashes

Initialisation time

programmed

Red

 flashes

quickly

Green flashes 

quickly

Motion detection

Red

 flashes 

on each 

detected

movement

Green flashes 

on each 

detected

movement

Too bright detected

Red

 flashes 

2x per 

second

Green flashes 

2x per 

second

Too bright / too dark /

undefined in opened state

Red

 flashes

very quickly

Green flashes

very quickly

Toggle DALI/DSI

DSI active

Red

 shines 

3 sec.

Toggle DALI/DSI  

DALI active

Green shines 

3 sec.

Toggle HA/VA  

HA active

White shines 

permanently

Toggle Preset/User  

Preset active

Red

 shines 

3 sec.

Toggle Preset/User  

User active

Green shines 

3 sec.

IR signal valid received

Red

 and 

white shine 

3 sec.

IR signal invalid received

Red

 shines 

0.5 sec.

100 h function active

Red / Green 

flash  

alternately

Red / Green 

flash  

alternately

Light measurement in

progress

Green 

flashes 1x in 

10 sec.

Green flashes 

1x in 10 sec.

  

Wall bracket for remote 

control IR-PD-DALI-1C 

IR-PD-DALI-1C

15.  Putting into operation of the remote control 

(optional)

Settings with remote control override the potentiometer 

and DIP settings.

The DIP settings are reactivated by 
• 

 setting the potentiometers to “TEST“ and ”SUN” (see 

section 24), or

• 

  pressing the “Reset” button on the remote control in 

open state

LUXOMAT

®

 IR-PD-DALI-1C

1. Check Battery:

 

Open battery compartment by pressing 

the plastic springs together and removing 

the battery-holder.

2. Note:

Using the remote control, the occupancy detector can only be 

operated brightness-depending. The setting „SUN“ can only be 

chosen with potentiometer A.
When using the remote control IR-PD-DALI-1C, we recommand to 

set potentiometer A to „SUN“. Pressing the RESET button on the 

remote control then resets the detector to brightness-independant 

mode (SUN).

!

16. Settings by remote control in open state

Unlocking device – 

Activation of the 

programming mode

Resetting 

when open: 

Deletes all 

values set with 

the remote 

control, light 

OFF.

Orientation light 

on/off

Automatic reading 

in the current light 

value as new lumi-

nance set value

or

Dimming of the 

lighting to the 

desired brightness 

value

Adjusting of the lumi-

nance set value from 

50 to 1500 Lux: 

+/–  

5   Lux steps

+/–  

10  Lux steps

+

/

 

20  Lux steps

max

50

Lux

1500

Lux

ON

OFF

max

50

Lux

1500

Lux

ON

OFF

DSI/

DALI

Switching between DSI 

and DALI program; 

The Factory setting 

is DALI

or

+

Full automatic /semi- 

automatic mode (se.18) 

Preset/user mode 

(see section 23) 

max

50

Lux

1500

Lux

ON

OFF

Follow-up time  

orientation light

at

min

10 

min

optional

optional

optional

optional

1. Start light meas-

urement by long 

press of the button  

(see section 17) 
2. Start LED ON/OFF 

by a short press of 

the button

Follow-up time  

Channel 1: 1 - 30 min.
Follow-up time  

Channel 2 (HVAC): 5 -  

60 min. or impulse

1

min

5

min

30

min

60

min

Exit programming mode

If there is no entry for 

about 3 min.

the programming

mode is ended

automatically.

Permanent double lock 

With this function, the 

detector is permanently 

locked. This mode can 

only be activated during 

5 sec. after closing the 

detector. In this mode, 

only the function „Light 

ON/OFF“ can be 

activated.

Red LED flashes

optional

max

50

Lux

1500

Lux

ON

OFF

t < 5 sec.