What should be done if ...

Possible problems

Solutions

1.  The lamp being controlled 

by 

LUXOMAT

®

 does not 

switch on.

- The halogen lamp is defective.

- The mains voltage is not present.

- The twilight value switch-on threshold is not 

correctly adjusted.

- Incorrect adjustment of the detection zone

- The detector is installed too high.

- The lenses in the sensor section are dirty.

- Replace the halogen lamp. 

- Check the connection and the fuses.

- Correct the switch-on threshold of the 

 

twilight switch using the rotary control.

- Change the detection zone.

- Change the installation height (maximum 3 meters).

- Clean the sensor lenses.

2. The lamp turns on too late. - The detector is installed too high.

- People approach the sensor directly.

- Change the installation height (maximum 3 meters). 

- Install the sensor in such a way that the detection zone is 

intersected.

3.  The lamps remain perma-

nently switched-on.

- Permanent movement of a heat source in 

the detection zone

- A switch has been installed parallel to the 

sensor in order to enable manual switching. 

- Remove the heat source from the detection zone. Check 

for correct functioning by covering the lens (the lamp must 

then switch-off).

- Put the switch in the “Sensor” position  in order to prevent 

manual switch-on.

4.  Unwanted switching-on

 

of the light

- Permanent movement of heat sources in the 

detection zone (trees, bushes being moved 

by the wind, the presence of cats or dogs 

in the detection zone)

- Direct sunshine on the sensor lens

- The sensor is placed directly over an air 

exhaust.

- Change the range of the sensor by changing the inclina-

tion or by attaching the shades to the lens. 

- Protect the lens from direct sunshine.

- Install the sensor at a different location.

5.  The detector range is too 

small.

- The sensor installation height is not optimal 

(too high or too low)

- People directly approach the detector.

- Hillside location 

- Change the installation height (2.50 meters). 

- Install the sensor in such a way that the detectionzone is 

intersected.

- Change the detector inclination.

6. Does not detect vehicles

-  The vehicle engine is not yet warm

 

(weak heat source)

9.  Mounting or replacement of the 

halogen lamps

Always verify that the mains voltage has been isolated

 

whenever the halogen lamps need to be replaced.

Caution:

 The floodlight can reach very high temperatures!

• Allow the lamp and the enclosure to cool down.
•  Remove the fastening screw from the enclosure of the 

floodlight and open the enclosure.

•  Grasp the defective halogen lamp tightly and remove it 

from its bracket.

• Do not touch the replacement lamps with your hands.
• Place the halogen lamp into the bracket.
•  Close the enclosure and be sure that the sealing ring is 

properly seated.

•  Close the enclosure with the fastening screws.

8. Troubleshooting

6.

 

Wiring diagram

Monitoring for narrow premises, ways, 

gateways or at door sills.

Monitoring two sides of a building, 

warehouses, parking lots.

2 m9 m

16 m

280°

20 m

2,50 m

Monitoring for narrow premises, ways, 

gateways or at door sills.

7. Detection area at 2.50 m mounting hight

LUXOMAT

®

 LC-Click-N 140

LUXOMAT

®

 

LC-Click-N 200

LUXOMAT

®

 

LC-plus 280

Standard mode with 1-channel motion detector external

AL20-CdS
ALC-ELU/D
AL20-280-BM
AL20-280-BM-LED
ALC-B-360
ALC-B-360-DECO
AL2-RC-plus-130/230/280
FLC-280-LED
FL2-LED-230
AL5-RC-plus next
AL5-LC
AL1
AL4

Übersicht

L

N

L

N

C1

E1

S1

Standard mode with 1-channel motion detector with NC pushbutton

Standard mode with 1-channel motion detector

T1 = NC button

Manual switching additionally possible (press opener ap-

prox. 2 sec.).

The position of the potentiometers should not be on “test” 

or “sun”. If so, the pre-set time and safety values get lost.

AL20-280-BM
AL20-280-BM-LED
ALC-B-360
ALC-B-360-DECO
AL2-RC-plus-130/230/280
FLC-280-LED
FL2-LED-230
AL5-RC-plus next
AL5-LC
AL1

Übersicht

L

N

L

N

C1

E1

T1

AL20-CdS
ALC-ELU/D
AL20-280-BM
AL20-280-BM-LED
ALC-B-360
ALC-B-360-DECO
AL2-RC-plus-130/230/280
FLC-280-LED
FL2-LED-230
AL5-RC-plus next
AL5-LC
AL1

max. 5 paralell

Übersicht

L

N

L

N

C1

E1

L

N

C1

10 Wiring diagrams

S1 = switch for permanent light

LC-plus next max. 5 parallel

10 m

140°

2,50 m

4 m

12 m

2 m

10 m

4 m

12 m

200°

2,50 m

2 m

L´ L N

PE
N
L

{

}

Motion detector

Flood light

Reviews: