background image

Installation Instructions 

Step 6 – Attaching Tube to Effective Life Indicator (ELI) 

a) Determine the length of tubing needed from the faucet to the ELI. A slight sag in the

line will allow for some ease in installation.  Cut the tubing to required length.

b) Insert other end of tubing firmly into the outlet port (John Guest® fitting) of the ELI

until fully engaged.

c) Pull tube gently to ensure the tubing is fully seated.

     Caution

:  Tube must be fully inserted in the compression fitting base on the outlet stem of the ELI. 

Step 7 – Connecting the Saddle Valve 

a) Determine the length of plastic tubing needed to connect the inlet (left) side of the filter

with the saddle valve.  Be sure to allow enough tubing to prevent kinking and cut the tubing
squarely.  Slide brass compression nut onto tubing, followed by plastic ferrule.  The long tapered
end of the ferrule should face towards the end of the tubing.  Place insert into tubing.

b) Insert tubing into saddle valve and hand-tighten compression nut.  Using a wrench, tighten nut

1 to 1 ½ turns.

        NOTE:

 All nuts must be retightened when the system reaches projected operating temperature. 

Step 8 – Connecting Inlet Line to System 

a) Insert other end of tubing firmly into inlet port (John Guest® fitting) until fully engaged.
b) Pull tube gently to ensure the tubing is fully seated.

Step 9 – Setting the Effective Life Indicator 

        NOTE:  The effective life indicator is the white dial located on the center of the

 

mounting bracket.

 

Each black mark on the dial represents 100 gallons (378

.5

 L).   

a) Move the dial clockwise so that the black indicator arrow lines up with the 1

1

00 gallon

(

4

,

16

4

 L) mark.

 Important:  Set flow meter to 1

1

00 gallons after each new filter replacement.

        NOTE: To prevent indicator malfunctions, only move the dial when the system is depressurized. 

Step 10 – Putting the System into Operation 

a) Slowly turn on cold water supply.
b) Rotate handle on base of drinking water faucet counter-clockwise to “ON” position.

Allow water to run for 10 minutes to flush air and carbon fines from filter cartridges.  Check
system for leaks before completing installation.

c) Make sure that all nuts are tightened.
NOTE:

  A drinking water cartridge may contain carbon fines (very fine black powder). It is recommended

that you run the tap at least 20 seconds prior to using water for drinking or cooking purposes.
NOTE:

  Initially, filtered water may appear cloudy.  If you set a glass of water on a level surface, you should

be able to watch the cloudiness disappear from the bottom of the glass upwards.  This harmless cloudiness
results from the release of trapped air with the cartridge and will disappear within a few weeks after installation.

INSTALLATION IS NOW COMPLETE. 

NOTE:  Based on the settings sensitivity of the Effective Life Indicator (ELI), user should set the ELI to 
1,100 gallons to assure a 1,000 gallon cycle.

Summary of Contents for 4000 Nanotechnology

Page 1: ... South Bloomington MN 55431 952 884 8417 Info bdavidwater com www bdavidwater com Installation and Operation Manual System tested and certified to meet the requirements of NSF Protocol P231 and NSF ANSI Standards 42 53 See performance data sheet for details 4000 Nanotechnology Certified Under Counter Filtration System Rev 05 17 2016 ...

Page 2: ...defective product or part B David Company will consider the customer s preference in good faith All claimed defective product must 1 be authorized for return by B David Company with an RGA number 2 include proof of the purchase date of the product or part 3 returned to B David Company prior to the expiration of the warranty date at the customer s expense shipment pre paid 4 be accompanied by a let...

Page 3: ...of water that is visually contaminated cloudy or has an obvious contamination source such as contamination by raw sewage v Systems certified for cyst reduction may be used on disinfected waters that may contain filterable cysts v System is not intended to convert wastewater or raw sewage into drinking water v Installation and plumbing should comply with all local laws and regulations Consult with ...

Page 4: ...inch 10mm cold water line Numbered diagrams correspond with numbered steps Step 1 Installing the Saddle Valve Use of a cordless drill is recommended To protect yourself from serious injury or fatal shock when using an electric drill be sure the drill and the outlet it is plugged into are properly grounded When using a drill follow the manufacturer s guidelines and procedures NOTE Saddle valve must...

Page 5: ...ond person hold the faucet while tightening the wing nut d Install the faucet spout into the base by pushing firmly into hole in base then screw fitting cover hand tight Caution Do not over tighten the wing nut Hand tighten only Do not use pliers or wrench to tighten Step 4 Mounting the system a Center system between water supply adapter and drinking water faucet NOTE Allow 1 5 inches 38mm clearan...

Page 6: ... Setting the Effective Life Indicator NOTE The effective life indicator is the white dial located on the center of the mounting bracket Each black mark on the dial represents 100 gallons 378 5 L a Move the dial clockwise so that the black indicator arrow lines up with the 1100 gallon 4 164 L mark Important Set flow meter to 1100 gallons after each new filter replacement NOTE To prevent indicator m...

Page 7: ...nd caps with dish soap and warm water Rinse thoroughly Then fillbottom ofeach housing1 3 full with water Add 1TBSP 14 7ML of household bleach and scrub to disinfect 5 Lubricate O rings with clean silicone grease Insert each O ring in groove and press into place NOTE This step is important to ensure a proper housing seal Make certain each O ring is seated level in its groove or a leak may occur 6 S...

Page 8: ...e are other leaks in system turn off water supply Problem No water or decreased water flow Correction Check flow at faucet The 4000 Nanotechnology Certified Under Counter Filtration System system should fill a gallon jug in approximately 2 minutes Flow rates will vary with individual household water pressure Correction Check filter cartridge installation Make certain all filter cartridges are prop...

Page 9: ...EXPLODED PARTS VIEW ...

Page 10: ......

Page 11: ......

Reviews: