background image

2

INTRODUCTION

The VenaTech® LP Brachial Introducer System (Antecubital) must be used with a
VenaTech® LP vena cava filter only.
The VenaTech® LP Brachial Introducer System (Antecubital) includes a 

96 cm long

(37.8 in.)

sheath, designed to be used during the implantation of a VenaTech® LP

vena cava filter via the Brachial approach (Antecubital).
Please refer to the VenaTech® LP instructions for use booklet (JUGULAR, or
SUBCLAVIAN for OUS only, approaches) for information about the use of a
VenaTech® LP vena cava filter.

SYSTEM CONTENTS

7F I.D. Introducer sheath with hemostasis valve and side connection

7F Dilator

7F Long Pusher (white)

7F Short Pusher (blue)

PTFE coated “J” guide, length = 180cm, diameter = 0.89mm (0.035 in)

For an implantation of a VenaTech® LP vena cava filter from the Brachial approach
(Antecubital), it is mandatory to use the above-mentioned accessories, instead of
the accessories available into the VenaTech® LP vena cava filter kit. The only items
that must be used from the VenaTech® LP vena cava filter kit are the following : 

Filter in its cartridge

Cartridge cradle

Instructions for use (JUGULAR, or SUBCLAVIAN for OUS only, approaches)

F1944_Ed02_Ang_1941 Ed.01 Angl  16/07/13  11:59  Page2

Summary of Contents for VenaTech LP

Page 1: ...KÇE CESKY JAZYK MAGYAR 0459 VenaTech LP Brachial Introducer System Antecubital For US market only Vena Cava Filter Brachial Introducer System Antecubital 1 REF 04439985 B en fr de es it sv pt no da fi pl el tr cs hu F1944 Ed 02 03 2014 F1944_Ed02_couv new_1944 Ed 02 Couverture 06 03 14 15 32 Page2 ...

Page 2: ...go de lote no Batch produksjonsserie kode da Batch kode fi Eränumero pl Numer serii el Κωδικός παρτίδας tr Lot no cs Číslo šarže hu LOT szám LOT en Sterilized using ethylene oxide fr Stérilisé en utilisant de l oxyde d éthylène de Sterilisation mit Ethylenoxid es Esterilización mediante Óxido de Etileno it Sterilizzato con Ossido di Etilene sv Steriliserad med ethylenoxid pt Esterilizado por óxido...

Page 3: ...ons for use for any other approach or for the implantation of any other vena cava filter VenaTech LP Brachial Introducer System Antecubital For US market only Vena Cava Filter Brachial Introducer System Antecubital 1 REF 04439985 Instructions for use for implantation via the brachial approach F1944_Ed02_Ang_1941 Ed 01 Angl 16 07 13 11 59 Page1 ...

Page 4: ...ena cava filter SYSTEM CONTENTS 7F I D Introducer sheath with hemostasis valve and side connection 7F Dilator 7F Long Pusher white 7F Short Pusher blue PTFE coated J guide length 180cm diameter 0 89mm 0 035 in For an implantation of a VenaTech LP vena cava filter from the Brachial approach Antecubital it is mandatory to use the above mentioned accessories instead of the accessories available into ...

Page 5: ...te for the implantation from the Brachial approach Implantation approach This Introducer System is designed for insertion via the Brachial approach Antecubital If needed this Introducer System can be used to insert the filter via the right internal jugular vein or the left or right subclavian veins In this case due to the length of the introducer it is important to rigorously follow aseptic techni...

Page 6: ... resterilized or reused Store at room temperature Avoid freezing and excessive heat Do not remove from unit carton until ready for use Caution Federal U S A Law restricts this device to sale by or on the order of a physician Opening the sterile packaging Confirm the date of sterile expiration on the labelling Never use an introducer system which has exceeded its sterile expiration date To maintain...

Page 7: ...zerrel Antecubital 2 fr Pour le marché américain uniquement de Nur für den US Markt es Solo para el mercado de EUA it Solo per il mercato USA sv Endast för amerikanska marknaden pt Exclusivamente para o mercado EUA no Kun for US markedet da Kun til brug i USA fi Vain USA n markkinoille pl Wyłącznie dla rynku Stanów Zjednoczonych el Μόνο για την αγορά των ΗΠΑ tr Sadece Amerika Birleşik Devletleri p...

Page 8: ...Antecubital REF 04439985 0459 F1944 Ed 02 03 2014 For US market only 2 Manufactured for 3 B Braun Interventional Systems Inc 824 Twelfth Avenue Bethlehem PA 18018 www bisusa org Customer Service ordering 4 Tel 877 VENA CAV 836 2228 Fax 610 849 1334 Technical support 5 Tel 800 443 VENA 8362 F1944_Ed02_couv new_1944 Ed 02 Couverture 06 03 14 15 32 Page1 ...

Reviews: