background image

5. USER INTERFACES

Continued from the previous page

Address

Access

Description

0x0601

R/W

Lower 16 bits of CNT2 counter value

0x0602

R/-

Prompt CNT2 frequency

0x0603

R/-

Average CNT2 frequency

0x0604

R/-

Minimal CNT2 frequency

0x0605

R/-

Maximal CNT2 frequency

...

0x0F00

R/-

Always 0x0000

0x0F01

R/-

Always 0x0000

0x0F02

R/-

Upper 16 bits of the number of seconds since January 1, 1970

0x0F03

R/-

Lower 16 bits of the number of seconds since January 1, 1970

0x0F04

R/-

Alarms status:

bit 0 – active level on BIN1 input

bit 1 – active level on BIN2 input

bit 2 – active level on BIN3 input

bit 3 – active level on BIN4 input

bit 4 – exceeded the lower limit of the AN1 analogue input

bit 5 – exceeded the upper limit of the AN1 analogue input

bit 6 – exceeded the lower limit of the AN2 analogue input

bit 7 – exceeded the upper limit of the AN2 analogue input

bit 8 – exceeded the limit frequency of CNT1

bit 9 – exceeded the limit frequency of CNT2

0x0F05

R/-

Status of the binary inputs:

bit 0 – level at the BIN1 input

bit 1 – level at the BIN2 input

bit 2 – level at the BIN3 input

bit 3 – level at the BIN4 input

bit 6 – level at the BOUT1 output

0x0F06

R/-

Recalculate value of AN1 (with sign)

0x0F07

R/-

Recalculate value of AN2 (with sign)

0x0F08

R/-

Upper 16 bits of CNT1

0x0F09

R/-

Lower 16 bits of CNT1

0x0F0A

R/-

Prompt CNT1 frequency

0x0F0B

R/-

Average CNT1 frequency

0x0F0C

R/-

Minimal CNT1 frequency

0x0F0D

R/-

Maximal CNT1 frequency

0x0F0E

R/-

Upper 16 bits of CNT2

0x0F0F

R/-

Lower 16 bits of CNT2

To be continued on the next page

31

Summary of Contents for spectre lte

Page 1: ...Cellular and Wired Routers SPECTRE LTE 3G RT USER S MANUAL...

Page 2: ...does not represent a commitment on the part of B B Electronics Mfg Co Inc B B Electronics Mfg Co Inc shall not be liable for incidental or consequential damages resulting from the furnishing performan...

Page 3: ...s 12 5 2 Status Indicators 13 5 2 1 Expansion Port Status Indicators 14 Ethernet Ports 14 RS 232 Ports 15 I O Ports 15 RS 485 422 Ports 15 Wi Fi 15 SmartMesh IP 15 5 3 Power Connector 16 5 4 Antenna C...

Page 4: ...t Output Connector 28 MODBUS ASCII Configuration and Address Space 29 6 Reset or Reboot 36 7 First Use 37 7 1 Starting the Router 38 7 2 Configuring the Router 38 Configuration over Web browser 38 Con...

Page 5: ...t and output of router 21 21 RS 232 port connector 22 22 Meter connection to router 22 23 Jumper position for external power supply left and internal power supply right 23 24 Jumper position for RS 48...

Page 6: ...Connection of power connector 16 15 Ethernet connector 18 16 Connection of USB connector 20 17 I O port connection 20 18 Connection of RS 232 connector 22 19 Connector pinout in RS 485 mode 24 20 Conn...

Page 7: ...il to support bbelec com Router Version The properties and settings associated with the cellular network connection are not available in noncellular SPECTRE RT routers PPPoE configuration is only avai...

Page 8: ...ure suitable for the environment The router must be used in compliance with all applicable international and national laws and in compliance with any special restrictions regulating the use of the rou...

Page 9: ...rs It is recommended to create an appropriate copy or backup of all the important settings that are stored in the memory of the device 2 2 Product Disposal Instructions The WEEE Waste Electrical and E...

Page 10: ...ndent upon the specific router model Configuration of the router may be done via a password protected Web interface The router supports the creation of VPN tunnels using IPsec OpenVPN and L2TP to ensu...

Page 11: ...ackage 3 4 Model Numbers Standard Features on SPECTRE Routers 10 100 Ethernet USB Host Port Binary I O Port Dual SIM Card slots Expansion Port Functions Model Dependent The Ports Can Be Connected As F...

Page 12: ...I O AI DI DO Wi Fi RTLTE 340 W VZ RS 422 485 Wi Fi RTLTE 350 VZ No connect SmartMesh IP RTLTE 351 VZ Ethernet SmartMesh IP RTLTE 352 VZ RS 232 SmartMesh IP RTLTE 354 VZ RS 422 485 SmartMesh IP Table 2...

Page 13: ...pansion Ports Model No Port 1 Port 2 RT3G 300 No connect No connect RT3G 302 No connect RS 232 RT3G 304 No connect RS 422 485 RT3G 310 Ethernet No connect RT3G 311 Ethernet SWITCH Ethernet SWITCH RT3G...

Page 14: ...Port 1 Port 2 ERT310 Ethernet No connect ERT311 Ethernet SWITCH Ethernet SWITCH ERT312 Ethernet RS 232 ERT314 Ethernet RS 422 485 ERT351 Etherent SmartMeshIP Table 5 SPECTRE RT Ethernet Router 3 5 Di...

Page 15: ...uidelines When using the supplied whip antennas maintain a distance of 6 cm from cables and metal surfaces on every side When using an external antenna unless in a switch board it is necessary to fit...

Page 16: ...length of the data cables exceeds 1 5 meters or if the cable leads towards the switch panel we recommend installing overvoltage protectors surge suppressors 3 Do not bundle the data cables with 120 23...

Page 17: ...ply data cables and antenna Removing from DIN rail Figure 6 DIN rail clip This is the default position of the DIN rail clip To remove the router from the DIN rail push the router up slightly so that t...

Page 18: ...ls only DIV SMA Diversity cellular antenna LTE models only GPS SMA GPS antenna LTE models only AUX SMA RP SMA 3G models on the left DIV GPS all models on the right SmartMesh IP antenna WIFI RP SMA Wi...

Page 19: ...PECTRE RT front panel example model ERT311 5 2 Status Indicators Caption Color State Description PWR Green Blinking On Fast blinking Router is ready Starting of the router Updating firmware DAT Red Bl...

Page 20: ...Selected 10 Mbit s ETH Yellow On Blinking Off The network cable is connected Data transmission The network cable is not connected PORT Green LED functions for different router configurations appear in...

Page 21: ...input 1 Table 10 I O Port LED status indication RS 485 422 Ports LED Port Indicator Green LED Blinks on Receive data Yellow LED Blinks on Transmit data Table 11 RS 232 LED status indication Wi Fi LED...

Page 22: ...y Protection against reversed polarity is built into the router The power consumption in receive mode is 2 3 W LTE models or 2 6 W 3G models The peak power consumption during data sending or communica...

Page 23: ...SPECTRE 3G There are always connectors AUX and DIV for main antenna and diversity GPS antenna the GPS mode is chosen internally by activating the GPS User Module in the router There can be antenna co...

Page 24: ...wer supply before handling the SIM card Press the small button on the right hand side of the SIM reader slot to eject the SIM card holder Insert the SIM card into the holder and slide it in the reader...

Page 25: ...gether with PORT 2 serial communications RS 232 see chapter 5 11 1 and RS 485 422 see chapter 5 11 2 12 bit I O AI DI DO see chapter 5 11 3 5 8 Port 2 Based on the model number see chapter 3 4 the exp...

Page 26: ...gure 18 USB connector 5 10 I O Port 3 Pin Panel Socket Pin No Signal mark Description Data Flow Direction 1 BIN0 Binary input Input 2 GND Signal ground 3 OUT0 Binary output Output Table 17 I O port co...

Page 27: ...S Connect the cable s I O connector to the router s I O port and tighten locking screws Circuit example of a binary input or output connected to the router Figure 20 Connection of binary input and out...

Page 28: ...port is protected against bus overload Figure 21 RS 232 port connector Panel socket RJ45 RS 232 DCE Data Communication Equipment Pin Signal Description Direction 1 RTS Request To Send Input 2 CTS Cle...

Page 29: ...J5 and J6 on the RS 485 module select the mode of the port either RS 485 or RS 422 mode If RS485 is required jumpers J4 and J5 must be connected and jumper J6 disconnected If RS422 is required jumpers...

Page 30: ...xRx RS485 B Input Output 6 TxRx RS485 A Input Output 7 12 V EXT External power supply 8 12 V EXT External power supply Table 19 Connector pinout in RS 485 mode ATTENTION The power supply is selected o...

Page 31: ...Pin Signal mark Description Data flow direction 1 SGND Signal and power supply ground 2 SGND Signal and power supply ground 3 RxD Receive data Output 4 RxD Receive data Output 5 TxD Transmit data Inpu...

Page 32: ...n to the router with data cable length less than 10 m Figure 30 RS 422 Connection to the router with data cable length more than 10 m With a RS422 data cable more than 10m long it is necessary to use...

Page 33: ...he ADC value stored in memory is calculated using the following equation ADC Value 12b value addit constant multiplic constant 1000 where the constants are programmed into memory by the user Binary In...

Page 34: ...oise on the input but also dissipates more power Figure 31 Threshold select using jumper on the board Input Output Connector Figure 32 12 bit I O CNT connector Panel socket RJ45 12 bit I O Pin Signal...

Page 35: ...ort 1 Using this protocol it is possible to configure the 12 bit I O board read the input status and control the output The I O port communicates at 9600 baud 8 bits no parity and 1 stop bit 8N1 MODBU...

Page 36: ...the number of seconds since January 1 1970 0x0007 R W Lower 16 bits of the number of seconds since January 1 1970 0x0008 R W Upper 16 bits of the current log number 0x0009 R W Lower 16 bits of the cu...

Page 37: ...nalogue input bit 5 exceeded the upper limit of the AN1 analogue input bit 6 exceeded the lower limit of the AN2 analogue input bit 7 exceeded the upper limit of the AN2 analogue input bit 8 exceeded...

Page 38: ...008 R 1st log upper 16 bits of CNT1 0x1009 R 1st log lower 16 bits of CNT1 0x100A R 1st log prompt CNT1 frequency 0x100B R 1st log average CNT1 frequency 0x100C R 1st log minimal CNT1 frequency 0x100D...

Page 39: ...analogue input bit 8 exceeded the limit frequency of CNT1 bit 9 exceeded the limit frequency of CNT2 0xF100 W Negative logic of binary inputs bit 0 BIN1 input bit 1 BIN2 input bit 2 BIN3 input bit 3 B...

Page 40: ...N2 additive constant with sign 0xF403 W AN2 hysteresis value with sign 0xF404 W AN2 lower limit with sign 0xF405 W AN2 upper limit with sign 0xF406 W Bits 7 3 AN2 switching time of measurement circuit...

Page 41: ...ddress Access Description 0xF601 W CNT2 Upper limit 0xF602 W CNT2 Time of limit exceeded sec 0xF603 W CNT2 Time for resetting measurement sec 0xFFFF W Turn off the the main source at the specified tim...

Page 42: ...the router Press RST button Table 23 Ways to reset or restart the router After the green LED starts to blink you may restore the router s initial settings by pressing button RST on front panel The ro...

Page 43: ...need to make all of the necessary connections The router cannot operate without a connected antenna SIM card for UMTS networks and a power supply Operating the router without an antenna can damage th...

Page 44: ...ioned for the necessary network LTE HSPA UMTS EDGE GPRS For 3G CDMA networks the router is provisioned over the air Refer to the Configuration manual for details on configuring the router based on the...

Page 45: ...ation of the router can be performed by means of the Telnet or SSH interface The default IP address of the router is 192 168 1 1 The username is root The password is root A detailed description of con...

Page 46: ...tection IP20 Supply voltage 10 to 30 V DC Class 2 Power Supply Only Consumption No communica tion Receive Mode Transmit GPRS Transmit others 1 6 W RT models 2 3 W LTE models 2 6 W 3G models up to 3 5...

Page 47: ...RS multislot class 12 CS 1 to 4 MCS 1 to 9 Transmit power LTE 23 dBm UMTS HSUPA HSDPA HSPA Class 3 23 dBm GSM850 CS Class 4 32 dBm GSM900 CS Class E2 27 dBm Supported channels GSM GPRS EDGE 850 900 18...

Page 48: ...arameters 3GPP Release 99 GSM GPRS Supported channels HSPA UMTS 850 900 AWS 1900 2100 MHz EGPRS 850 900 1800 1900 MHz CDMA 800 1900 MHz GPS Assisted Mode Table 27 SPECTRE 3G cellular module specificat...

Page 49: ...munity Safety Isolation EN 55022 B ETS 300 342 EN 60950 EN 60747 Wi Fi specifications 802 11 b g n RX Sensitivity TX Output power 11b 11Mbps 11g 54Mbps HT20 11n MSC7 HT20 11n MSC7 11b 11Mbps 11g 54Mbp...

Page 50: ...15 2405 5 k 11 MHz Modulation IEEE 802 15 4 Direct Sequence Spread Spectrum DSSS Raw Data Rate 250 kbps Range 25 C 50 RH 2 dBi Omni Directional An tenna Antenna 2 m above ground Indoor Outdoor 100 m 3...

Page 51: ...necessary to set ping which will check the connection and in the case of failed ping restart the connection Q PPP connection cannot be established DAT LED off Recheck GPRS settings APN name password...

Page 52: ...t clean the router with harsh chemicals solvents or abrasive cleaners RT and 3G models B B Electronics hereby declares that the models RT and 3G of the router described in this user s guide fits all b...

Reviews: